The Teledyne LeCroy HDO4104-MS is a 1 GHz, 4-channel High Definition Oscilloscope featuring 12-bit ADC technology, a 12.1-inch widescreen touch display, and 16 integrated digital channels for comprehensive mixed-signal design and debugging.

Specifications

General

ParameterValue
InterfacesLAN (10/100/1000Base-T Ethernet), 4x USB Host (2 front, 2 rear), 1x USB Device, GPIB (optional via external adapter), LXI Class C
Display12.1-inch widescreen capacitive touchscreen, 1280 x 800 resolution

Physical

ParameterValue
Power Supply100 - 240 VAC (±10%) at 50/60 Hz (±10%), 100 - 120 VAC (±10%) at 400 Hz; 200 W maximum power consumption
Operating Temperature5 to 40
Dimensions (W×H×D)399 × 291 × 131
Weight5.8
VESA Mount Pattern100 mm x 100 mm

Vertical System - Analog

ParameterValue
Analog Bandwidth (-3 dB)1 GHz
Number of Analog Channels4
Vertical Resolution (ADC)12 bits
Vertical Resolution (ERES)Up to 15 bits
Calculated Rise Time (10% to 90%)350 ps (typical)
Input Impedance (Analog)50 Ω ±1.0% or 1 MΩ ±1.0% || 16 pF
Input Coupling50 Ω: DC; 1 MΩ: AC, DC, GND
Input Sensitivity Range (50 Ω)1 mV/div - 1 V/div
Input Sensitivity Range (1 MΩ)1 mV/div - 10 V/div
DC Gain Accuracy±0.5% of full scale
Maximum Input Voltage (50 Ω)5 Vrms
Maximum Input Voltage (1 MΩ)400 V max (DC + Peak AC <= 10 kHz)
Hardware Bandwidth Limits20 MHz, 200 MHz

Vertical System - Digital

ParameterValue
Number of Digital Channels16
Input Impedance (Digital)100 kΩ || 5.0 pF
Maximum Input Voltage (Digital)±30 V non-destruct
Threshold SelectionTTL, CMOS, ECL, PECL, LVDS, User-Defined
User-Defined Threshold Range±10 V in 10 mV steps
Minimum Input Voltage Swing500 mV p-p

Horizontal System

ParameterValue
Maximum Real-Time Sampling Rate (Analog)2.5 GS/s (all channels)
Maximum Sampling Rate (Digital)1.25 GS/s
Standard Record Length12.5 Mpts/ch (all channels)
Maximum Record Length25 Mpts/ch (with HDO4K-MEM-EXT option)
Time Base Range200 ps/div - 1000 s/div
Time Base Accuracy±10 ppm
Minimum Detectable Pulse Width (Digital)2 ns
Timebase Delay RangePre-trigger: 0% to 100% of full scale; Post-trigger: 0 to 10,000 divisions

Trigger System

ParameterValue
Trigger SourcesAny input channel, External, Line, Ext/10
Trigger ModesAuto, Normal, Single, Stop
Trigger CouplingAC, DC, HFRej, LFRej
Trigger Holdoff Range2 ns - 20 s (or 1 to 99,999,999 events)
Edge TriggeringTriggers on rising, falling, or both edges
Runt TriggeringPositive or negative runts defined by two thresholds
Pulse Width Triggering2 ns - 20 s
Interval Triggering2 ns - 20 s
Dropout Triggering2 ns - 20 s
External Trigger Input Impedance1 MΩ || 16 pF
External Trigger Maximum Input Voltage400 V max (DC + Peak AC ≤ 10 kHz)
Trigger Jitter< 2.8 ps rms (typical), < 1 ps rms (typical) with Software Assisted Trigger
Internal Trigger Level Range±4.1 divisions from center
External Trigger Level Range±400 mV (EXT), ±4 V (EXT/10)
Edge Trigger Sensitivity (Internal)0.9 div (< 10 MHz), 1.0 div (< 200 MHz), 1.5 div (< 500 MHz), 2.0 div (< 1 GHz)

Acquisition System

ParameterValue
Acquisition ModesReal-time, Roll, Sequence (Segmented Memory)
Sequence Mode SegmentsUp to 10,000 segments
Averaging Factor RangeSummed or continuous averaging up to 1,000,000 sweeps
Sequence Mode Minimum Inter-segment Time1.0 µs

Waveform Measurements and Analysis

ParameterValue
Automatic Voltage and Time MeasurementsUp to 8 displayed simultaneously with statistics
Basic Math FunctionsAdd, Subtract, Multiply, Divide, FFT, Absolute Value, Average, Derivative, Envelope, Enhanced Resolution, Integral, Invert, Reciprocal, Rescale, Square, Square Root, Zoom
FFT Window TypesVon Hann (Hanning), Hamming, Flat Top, Blackman-Harris, Rectangular
FFT Vertical Scale OptionsdBm, dBV, Vrms, Industry Standard Units

Connectivity and Ports

ParameterValue
Auxiliary OutputTrigger Out, Pass/Fail
Reference Clock Input10 MHz (BNC connector)

Processor and Storage

ParameterValue
Internal Operating SystemWindows Embedded Standard 7 (64-bit)
System Memory (RAM)4 GB (standard)

Environmental Specifications

ParameterValue
Storage Temperature Range-20 °C to 60 °C
Operating Humidity Range5% to 80% RH (non-condensing) up to 30 °C

Compliance and Standards

ParameterValue
Calibration Interval1 year

Display

ParameterValue
Display Resolution1280 × 800 (WXGA)
Touch ScreenResistive touch screen
Display Size12.1 inches (30.7 cm) diagonal

Analog Vertical System

ParameterValue
Probes InterfaceProBus
Offset Range (1 MΩ)±1 V (1 mV - 4.98 mV), ±1.5 V (5 mV - 9.9 mV), ±3 V (10 mV - 19.8 mV), ±8 V (20 mV - 99 mV), ±15 V (100 mV - 198 mV), ±80 V (200 mV - 990 mV), ±150 V (1 V - 1.98 V), ±400 V (2 V - 10 V)

Digital Vertical System

ParameterValue
Digital Channel Maximum Input Frequency250 MHz
Digital Threshold Settings2 independent threshold controls (D0-D7 and D8-D15)

Connectivity

ParameterValue
Host USB Ports6 x USB 2.0 (2 front, 4 rear)
LAN Port1 x RJ-45 (10/100/1000Base-T)

Math and Analysis

ParameterValue
Zoom Traces4 standard zoom traces

Power

ParameterValue
Power Consumption (Maximum)320 VA
Power Consumption (Typical)150 W

Vertical System

ParameterValue
Hardware Bandwidth Limit Filters20 MHz, 200 MHz
Channel-to-Channel Isolation> 100:1 up to 250 MHz, > 40:1 up to 1 GHz

Digital Channels

ParameterValue
Digital Channel Record Length25 Mpts
Digital Channel Vertical Resolution1 bit
Digital Input Dynamic Range±20 V
Digital Trigger TypesEdge, Pattern, State

Interfaces

ParameterValue
USB Device Port1 x USB 2.0 Type-B (supports USBTMC)
External Display Outputs1 x HDMI, 1 x DisplayPort
LXI ComplianceLXI Class C

Power Requirements

ParameterValue
AC Input Voltage100 to 240 VAC (±10%)
AC Input Frequency50/60 Hz (±10%) at 100 to 240 VAC, 400 Hz (±5%) at 100 to 120 VAC

Compliance

ParameterValue
Safety ComplianceConforms to EN 61010-1:2010, EN 61010-2-030:2010, UL 61010-1, CAN/CSA C22.2 No. 61010-1-12
EMC ComplianceConforms to EN 61326-1:2006, EN 61326-2-1:2006

Technology

Digital Oscilloscope with HD4096 High Definition Technology

Applications

Mixed-signal design, embedded systems debugging, power analysis, and precision analog measurements

Looking for the LeCroy (Teledyne LeCroy) HDO4104-MS?

Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.

Selling this kind of equipment? Sell with us