The Teledyne LeCroy WavePro 760Zi-A is a high-performance 6 GHz, 4-channel digital storage oscilloscope featuring up to 40 GS/s sampling, a 15.4" WXGA color display, and advanced X-Stream II architecture optimized for rapid throughput, long memory, and responsive analysis.

Specifications

General

ParameterValue
Interfaces10/100/1000BaseT Ethernet (RJ45), Minimum 6 x USB 2.0 (3 on front panel), External Monitor Port, LBUS, Optional GPIB (IEEE-488.2), Optional LSIB (PCIe Gen1 x4)
Display15.4" WXGA Color Display
Calibration Interval1 year
Compliance & CertificationsCE Compliant, UL and cUL Listed; Conforms to EN 61010-1, EN 61326-1

Physical

ParameterValue
Power Supply100 - 240 VAC ±10% at 50/60 Hz, 115 VAC ±10% at 400 Hz; Max Power Consumption: 975 W (975 VA)
Operating Temperature5 to 40
Dimensions (W×H×D)467 x 355 x 312
Weight18.4

Vertical System

ParameterValue
Analog Bandwidth6 GHz
Rise Time (10% to 90%)70 ps typical (flatness mode)
Number of Input Channels4
Hardware Bandwidth Limits20 MHz, 200 MHz, 1 GHz, 3 GHz, 4 GHz
Input Impedance50 ohms ±2% or 1 Mohm || 16 pF (10 Mohm || 11 pF with supplied probe)
Input CouplingProLink Inputs - 50 ohms: DC, GND; ProBus Inputs - 1 Mohm: AC, DC, GND; 50 ohm: DC, GND
Maximum Input Voltage (50 ohms ProBus)±5 Vrms
Maximum Input Voltage (50 ohms ProLink)±4 Vpeak
Input TypesProBus and ProLink (supports multiplexing of up to 8 probes)
Vertical Resolution8-bit (up to 11-bit with Enhanced Resolution ERES)
DC Gain Accuracy±1.5% of full scale
Vertical Sensitivity (50 Ohm)2 mV/div - 1 V/div
Vertical Sensitivity (1 MOhm)2 mV/div - 10 V/div
Channel-to-Channel Isolation> 150:1 (up to 1.5 GHz), > 80:1 (up to 3 GHz), > 30:1 (up to 6 GHz)
Rise Time (20% to 80%)55 ps (typical)
Maximum Input Voltage (1 MOhm)400 V max (DC + Peak AC <= 10 kHz)
Channel-to-Channel Deskew Range±9 ns

Horizontal System

ParameterValue
Maximum Real-Time Sampling Rate40 GS/s on 2 Ch, 20 GS/s on 4 Ch
Equivalent-Time Sampling Rate (RIS)200 GS/s for repetitive signals (20 ps/div to 10 ns/div)
Time Base Range (Real-Time)20 ps/div - 1000 s/div
Time Base Range (RIS Mode)20 ps/div - 10 ns/div
Time Base Range (Roll Mode)Up to 1000 s/div (user selectable at >=100 ms/div)
Time Base CommonalityInternal timebase common to four input channels; external clock applicable at auxiliary input
Timebase Accuracy±1 ppm + aging (±1.0 ppm first year)

Acquisition System

ParameterValue
Standard Memory (4 Channels)20 Mpts
Standard Memory (2 Channels)40 Mpts
Standard Memory (1 Channel)40 Mpts
Standard Memory Max Segments3000
Memory Option S-3232M (4 Ch) / 64M (2 Ch) / 64M (1 Ch) (15,000 max segments)
Memory Option M-6464M (4 Ch) / 128M (2 Ch) / 128M (1 Ch) (15,000 max segments)
Memory Option L-128128M (4 Ch) / 256M (2 Ch) / 256M (1 Ch) (15,000 max segments)
Maximum Waveform Capture Rate1,000,000 waveforms/second (in Sequence Mode, up to 4 channels)
Intersegment Time1 µs

Trigger System

ParameterValue
Trigger ModesNormal, Auto, Single, Stop
Basic TriggersEdge, Window, TV-Composite Video
SMART TriggersState or Edge Qualified, Qualified First, Dropout, Pattern
Trigger SourcesAny input channel, Aux, Aux/10, or line
Trigger Coupling ModesDC, AC, HFRej, LFRej
Pre-trigger Delay Range0-100% of memory size (adjustable in 1% increments or 100 ns)
Post-trigger Delay Range0-10,000 divisions in real time mode (limited at slower time/div or roll mode)
Trigger Hold-off RangeFrom 2 ns up to 20 s or from 1 to 99,999,999 events
Internal Trigger Range±4.1 divisions from center
External Trigger Input Range (Aux)±0.4 V
External Trigger Input Range (Aux/10)±4 V
Maximum SMART Trigger Frequency2.0 GHz @ >= 10 mV/div
Minimum Triggerable SMART Width200 ps
Serial Triggering OptionUp to 2.7 Gb/s serial patterns, up to 80-bit length
Hardware Clock RecoveryOptional
Trigger Capture OptimizationTriggerScan (captures signals up to 100X faster using high-speed hardware triggering)
Trigger Jitter< 2.8 ps rms (typical), < 100 fs rms (with Software Assisted Trigger)

Connectivity and Ports

ParameterValue
Remote Control ProtocolsWindows Automation, LeCroy Remote Command Set
Network Communication ProtocolsVXI-11, VICP, LXI Class C (v 1.2) Compliant
GPIB Interface SupportOptional (IEEE-488.2)
LSIB Interface SupportOptional (PCIe Gen1 x4 protocol with LeCroy supplied API)
Ethernet Interface10/100/1000BaseT (RJ45 port)
USB Ports Configuration6 USB 2.0 ports (2 front, 4 rear)
Peripheral Bus StandardLeCroy LBUS standard

Processor and Storage

ParameterValue
Processor ArchitectureX-Stream II (optimized for fast throughput, long memory, and responsiveness)

Waveform Measurements and Analysis

ParameterValue
Advanced Search and AnalysisWaveScan (more than 20 search modes)
Mixed Signal Option4 + 36 channel MSO option available
Jitter and Timing AnalysisOptional analysis package available
Spectrum Analyzer AnalysisOptional spectrum analyzer package available
Digital Filter SoftwareOptional digital filter package available

Clock System

ParameterValue
External Clock Input10 MHz (50 Ohm, -10 dBm to +14 dBm)
External Clock Output10 MHz (50 Ohm, Sine wave, 0 dBm minimum)

Environmental

ParameterValue
Operating Humidity5% to 80% RH (non-condensing) up to +31 °C, derating to 50% RH at +40 °C
Operating AltitudeUp to 3,048 m (10,000 ft) at or below +25 °C

Computer System

ParameterValue
Operating SystemWindows 7 Professional (64-bit)
System Storage250 GB or larger removable Hard Disk Drive

Timebase System

ParameterValue
Sample Clock Jitter125 fs rms (typical)

Power Requirements

ParameterValue
Power Requirements100-240 VAC (±10%) at 50/60 Hz, 100-120 VAC (±10%) at 400 Hz
Power Consumption (Typical)800 W / 800 VA
Power Consumption (Maximum)975 W / 975 VA (with all accessories)

Interfaces

ParameterValue
Probe SupportProLink (channels 1-4) and ProBus (channels 1-4)

Math & Measurements

ParameterValue
Standard Math FunctionsUp to 8 math traces (FFT, ERES, Average, Envelope, etc.)

Technology

Digital Storage Oscilloscope (DSO)

Applications

Electronic design, debugging, validation, analysis, and compliance testing