The Teledyne LeCroy WavePro 760Zi-A is a high-performance 6 GHz, 4-channel digital storage oscilloscope featuring up to 40 GS/s sampling, a 15.4" WXGA color display, and advanced X-Stream II architecture optimized for rapid throughput, long memory, and responsive analysis.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | 10/100/1000BaseT Ethernet (RJ45), Minimum 6 x USB 2.0 (3 on front panel), External Monitor Port, LBUS, Optional GPIB (IEEE-488.2), Optional LSIB (PCIe Gen1 x4) |
| Display | 15.4" WXGA Color Display |
| Calibration Interval | 1 year |
| Compliance & Certifications | CE Compliant, UL and cUL Listed; Conforms to EN 61010-1, EN 61326-1 |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 - 240 VAC ±10% at 50/60 Hz, 115 VAC ±10% at 400 Hz; Max Power Consumption: 975 W (975 VA) |
| Operating Temperature | 5 to 40 |
| Dimensions (W×H×D) | 467 x 355 x 312 |
| Weight | 18.4 |
Vertical System
| Parameter | Value |
|---|---|
| Analog Bandwidth | 6 GHz |
| Rise Time (10% to 90%) | 70 ps typical (flatness mode) |
| Number of Input Channels | 4 |
| Hardware Bandwidth Limits | 20 MHz, 200 MHz, 1 GHz, 3 GHz, 4 GHz |
| Input Impedance | 50 ohms ±2% or 1 Mohm || 16 pF (10 Mohm || 11 pF with supplied probe) |
| Input Coupling | ProLink Inputs - 50 ohms: DC, GND; ProBus Inputs - 1 Mohm: AC, DC, GND; 50 ohm: DC, GND |
| Maximum Input Voltage (50 ohms ProBus) | ±5 Vrms |
| Maximum Input Voltage (50 ohms ProLink) | ±4 Vpeak |
| Input Types | ProBus and ProLink (supports multiplexing of up to 8 probes) |
| Vertical Resolution | 8-bit (up to 11-bit with Enhanced Resolution ERES) |
| DC Gain Accuracy | ±1.5% of full scale |
| Vertical Sensitivity (50 Ohm) | 2 mV/div - 1 V/div |
| Vertical Sensitivity (1 MOhm) | 2 mV/div - 10 V/div |
| Channel-to-Channel Isolation | > 150:1 (up to 1.5 GHz), > 80:1 (up to 3 GHz), > 30:1 (up to 6 GHz) |
| Rise Time (20% to 80%) | 55 ps (typical) |
| Maximum Input Voltage (1 MOhm) | 400 V max (DC + Peak AC <= 10 kHz) |
| Channel-to-Channel Deskew Range | ±9 ns |
Horizontal System
| Parameter | Value |
|---|---|
| Maximum Real-Time Sampling Rate | 40 GS/s on 2 Ch, 20 GS/s on 4 Ch |
| Equivalent-Time Sampling Rate (RIS) | 200 GS/s for repetitive signals (20 ps/div to 10 ns/div) |
| Time Base Range (Real-Time) | 20 ps/div - 1000 s/div |
| Time Base Range (RIS Mode) | 20 ps/div - 10 ns/div |
| Time Base Range (Roll Mode) | Up to 1000 s/div (user selectable at >=100 ms/div) |
| Time Base Commonality | Internal timebase common to four input channels; external clock applicable at auxiliary input |
| Timebase Accuracy | ±1 ppm + aging (±1.0 ppm first year) |
Acquisition System
| Parameter | Value |
|---|---|
| Standard Memory (4 Channels) | 20 Mpts |
| Standard Memory (2 Channels) | 40 Mpts |
| Standard Memory (1 Channel) | 40 Mpts |
| Standard Memory Max Segments | 3000 |
| Memory Option S-32 | 32M (4 Ch) / 64M (2 Ch) / 64M (1 Ch) (15,000 max segments) |
| Memory Option M-64 | 64M (4 Ch) / 128M (2 Ch) / 128M (1 Ch) (15,000 max segments) |
| Memory Option L-128 | 128M (4 Ch) / 256M (2 Ch) / 256M (1 Ch) (15,000 max segments) |
| Maximum Waveform Capture Rate | 1,000,000 waveforms/second (in Sequence Mode, up to 4 channels) |
| Intersegment Time | 1 µs |
Trigger System
| Parameter | Value |
|---|---|
| Trigger Modes | Normal, Auto, Single, Stop |
| Basic Triggers | Edge, Window, TV-Composite Video |
| SMART Triggers | State or Edge Qualified, Qualified First, Dropout, Pattern |
| Trigger Sources | Any input channel, Aux, Aux/10, or line |
| Trigger Coupling Modes | DC, AC, HFRej, LFRej |
| Pre-trigger Delay Range | 0-100% of memory size (adjustable in 1% increments or 100 ns) |
| Post-trigger Delay Range | 0-10,000 divisions in real time mode (limited at slower time/div or roll mode) |
| Trigger Hold-off Range | From 2 ns up to 20 s or from 1 to 99,999,999 events |
| Internal Trigger Range | ±4.1 divisions from center |
| External Trigger Input Range (Aux) | ±0.4 V |
| External Trigger Input Range (Aux/10) | ±4 V |
| Maximum SMART Trigger Frequency | 2.0 GHz @ >= 10 mV/div |
| Minimum Triggerable SMART Width | 200 ps |
| Serial Triggering Option | Up to 2.7 Gb/s serial patterns, up to 80-bit length |
| Hardware Clock Recovery | Optional |
| Trigger Capture Optimization | TriggerScan (captures signals up to 100X faster using high-speed hardware triggering) |
| Trigger Jitter | < 2.8 ps rms (typical), < 100 fs rms (with Software Assisted Trigger) |
Connectivity and Ports
| Parameter | Value |
|---|---|
| Remote Control Protocols | Windows Automation, LeCroy Remote Command Set |
| Network Communication Protocols | VXI-11, VICP, LXI Class C (v 1.2) Compliant |
| GPIB Interface Support | Optional (IEEE-488.2) |
| LSIB Interface Support | Optional (PCIe Gen1 x4 protocol with LeCroy supplied API) |
| Ethernet Interface | 10/100/1000BaseT (RJ45 port) |
| USB Ports Configuration | 6 USB 2.0 ports (2 front, 4 rear) |
| Peripheral Bus Standard | LeCroy LBUS standard |
Processor and Storage
| Parameter | Value |
|---|---|
| Processor Architecture | X-Stream II (optimized for fast throughput, long memory, and responsiveness) |
Waveform Measurements and Analysis
| Parameter | Value |
|---|---|
| Advanced Search and Analysis | WaveScan (more than 20 search modes) |
| Mixed Signal Option | 4 + 36 channel MSO option available |
| Jitter and Timing Analysis | Optional analysis package available |
| Spectrum Analyzer Analysis | Optional spectrum analyzer package available |
| Digital Filter Software | Optional digital filter package available |
Clock System
| Parameter | Value |
|---|---|
| External Clock Input | 10 MHz (50 Ohm, -10 dBm to +14 dBm) |
| External Clock Output | 10 MHz (50 Ohm, Sine wave, 0 dBm minimum) |
Environmental
| Parameter | Value |
|---|---|
| Operating Humidity | 5% to 80% RH (non-condensing) up to +31 °C, derating to 50% RH at +40 °C |
| Operating Altitude | Up to 3,048 m (10,000 ft) at or below +25 °C |
Computer System
| Parameter | Value |
|---|---|
| Operating System | Windows 7 Professional (64-bit) |
| System Storage | 250 GB or larger removable Hard Disk Drive |
Timebase System
| Parameter | Value |
|---|---|
| Sample Clock Jitter | 125 fs rms (typical) |
Power Requirements
| Parameter | Value |
|---|---|
| Power Requirements | 100-240 VAC (±10%) at 50/60 Hz, 100-120 VAC (±10%) at 400 Hz |
| Power Consumption (Typical) | 800 W / 800 VA |
| Power Consumption (Maximum) | 975 W / 975 VA (with all accessories) |
Interfaces
| Parameter | Value |
|---|---|
| Probe Support | ProLink (channels 1-4) and ProBus (channels 1-4) |
Math & Measurements
| Parameter | Value |
|---|---|
| Standard Math Functions | Up to 8 math traces (FFT, ERES, Average, Envelope, etc.) |
Technology
Digital Storage Oscilloscope (DSO)
Applications
Electronic design, debugging, validation, analysis, and compliance testing