The National Instruments PXI-4070 is a high-performance 6½-digit digital multimeter (FlexDMM) and a 300 V isolated waveform digitizer in a single-slot PXI module. It delivers exceptionally fast measurement speeds of up to 100 S/s at 6½ digits and up to 3 kS/s at 5½ digits, alongside high-precision 10-bit to 23-bit waveform acquisition up to 1.8 MS/s. Designed for automated testing, R&D, and production environments, it integrates seamlessly with NI switches for high-density, multi-channel data acquisition.

Specifications

General

ParameterValue
InterfacesPXI backplane
DisplayNone (Virtual front panel via host PC)

Physical

ParameterValue
Operating Temperature0 °C to 55 °C
Dimensions (W×H×D)20 mm × 130 mm × 216 mm

Resolution and Display

ParameterValue
Digits of Resolution6½ digits
Display TypeVirtual front panel (no physical display)

DC Voltage

ParameterValue
DC Voltage Ranges100 mV, 1 V, 10 V, 100 V, 300 V
DC Voltage Best Accuracy±6 ppm
DC Voltage Best Resolution100 nV
DC Voltage Input Impedance>10 GΩ (100 mV to 10 V ranges), 10 MΩ (100 V and 300 V ranges)
DC Voltage Normal Mode Rejection Ratio (NMRR)>60 dB (at 50 Hz / 60 Hz)
DC Voltage Common Mode Rejection Ratio (CMRR)>140 dB (at 50 Hz / 60 Hz)

AC Voltage

ParameterValue
AC Voltage Measurement TypeTrue-RMS
AC Voltage Ranges50 mV, 500 mV, 5 V, 50 V, 300 V
AC Voltage Frequency Range1 Hz to 300 kHz
AC Voltage Best Resolution100 nV
AC Voltage Input Impedance1 MΩ in parallel with 90 pF
AC Voltage Maximum Crest Factor4.5

DC Current

ParameterValue
DC Current Ranges20 mA, 200 mA, 1 A
DC Current Best Resolution10 nA
DC Current Input ProtectionF 1.25 A 250 V fast-acting fuse

AC Current

ParameterValue
AC Current Measurement TypeTrue-RMS
AC Current Ranges10 mA, 100 mA, 1 A
AC Current Frequency Range1 Hz to 10 kHz
AC Current Best Resolution10 nA

Resistance

ParameterValue
Resistance Measurement Configurations2-wire, 4-wire, 6-wire (with PXI-4022 accessory)
Resistance Ranges100 Ω, 1 kΩ, 10 kΩ, 100 kΩ, 1 MΩ, 10 MΩ, 100 MΩ
Resistance Best Resolution100 µΩ
Offset CompensationSupported (Offset Compensated Ohms)

Frequency and Period

ParameterValue
Frequency Range1 Hz to 500 kHz
Period Range2 µs to 1 s

Digitizer / Waveform Acquisition

ParameterValue
Digitizer Sampling Rate10 S/s to 1.8 MS/s
Digitizer Resolution10 to 23 bits (flexible resolution dependent on sampling rate)
Digitizer Maximum Input Voltage±300 V
Digitizer Bandwidth300 kHz
Digitizer Input CouplingDC

System Speed and Performance

ParameterValue
Reading Rate at 6½ Digits100 S/s
Reading Rate at 5½ Digits3 kS/s
Integration TimeVariable (software-programmable)
Guarding Module AccessoryNI PXI-4022 (enables 6-wire resistance & picoampere measurements)
Recommended Switch ModulesNI PXI-2527 (64-channel 300 V multiplexer), NI PXI-2530 (128-channel reed relay multiplexer)

Triggering and Math Functions

ParameterValue
Trigger SourcesPXI Trigger lines, PXI Star Trigger, Immediate, Software, External (via PXI chassis)

Power and Environmental

ParameterValue
Storage Temperature Range-40 °C to 70 °C
Operating Humidity Range10% to 90% RH (non-condensing)
Warm-up Time60 minutes
Calibration Interval1 year
Measurement Category (CAT) RatingCAT I (300 V)
Overvoltage Protection300 VDC/VAC

Physical Characteristics

ParameterValue
Form Factor3U PXI (1 slot)
Front Panel Connectors4 Banana jacks (HI, LO, HI Sense, LO Sense)

Power

ParameterValue
PXI Backplane Power Draw (+5 V)1.1 A max
PXI Backplane Power Draw (+12 V)150 mA max

Interfaces

ParameterValue
Bus Connector32-bit PXI/cPCI

Safety & Protection

ParameterValue
Maximum Common-Mode Voltage300 V DC or AC rms (between LO and Earth Ground)

Measurements

ParameterValue
Diode Test Current1 mA (fixed)
Supported Temperature SensorsRTD (Pt100, Pt385, Pt392), Thermistors (2.2k, 3k, 5k, 10k, 30k)

Digitizer Specifications

ParameterValue
Digitizer Resolution Range10 to 23 bits

Noise Rejection & Isolation

ParameterValue
AC Common Mode Rejection Ratio (CMRR)>70 dB (DC to 60 Hz, 1 kΩ imbalance in LO lead)

Input Characteristics

ParameterValue
Input Bias Current<30 pA

Environmental & Safety

ParameterValue
Pollution Degree2
Maximum Operating Altitude2000 m

Software & Control

ParameterValue
Software Driver SupportNI-DMM

Technology

Solid-state FlexDMM

Applications

Automated Test Equipment (ATE), high-precision measurement, R&D, and production testing

Looking for the National Instruments PXI-4070?

Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.

Selling this kind of equipment? Sell with us