The Sorensen DCR300 series (part of the DCRA/B family from Ametek) consists of heavy-duty, highly regulated, SCR phase-controlled DC power supplies. Engineered for either bench or rackmount applications, these supplies (including the DCR 300-1.5B, DCR 300-3B, and DCR 300-9B) combine the high efficiency of SCR phase control with a passive LC filter to deliver up to 300V of precise DC output. They feature automatic crossover between constant-voltage and constant-current modes, analog programming, remote sensing, and comprehensive protection systems.

Specifications

General

ParameterValue
InterfacesAnalog programming (resistance, voltage), remote sensing, series/parallel master-slave
DisplayDual analog meters (voltage and current)

Physical

ParameterValue
Power Supply115 Vac (103-127 Vac) or 208 Vac (187-229 Vac) single-phase (model dependent), 50-63 Hz
Operating Temperature0 to +70 °C
Dimensions (W×H×D)482.6 mm (W) x 133.3 to 311.0 mm (H) x 457.0 to 559.0 mm (D) (model dependent)
Weight18.1 / 30.3 / 63.5 kg (model dependent)

Output Specifications

ParameterValue
Rated Output Voltage Range0 to 300 Vdc
Rated Output Current (DCR 300-1.5B)0 to 1.5 Adc
Rated Output Current (DCR 300-3B)0 to 3.0 Adc
Rated Output Current (DCR 300-9B)0 to 9.0 Adc
Maximum Output Power (DCR 300-1.5B)450 W
Maximum Output Power (DCR 300-3B)900 W
Maximum Output Power (DCR 300-9B)2700 W
Line Regulation (Voltage)0.05% of maximum output voltage (150 mV)
Load Regulation (Voltage)0.05% of maximum output voltage (150 mV)
Line Regulation (Current)0.15% of maximum output current
Load Regulation (Current)0.15% of maximum output current
Output Ripple and Noise (RMS)450 mV RMS
Transient Recovery Time50 ms typical (recovery to within 1% of regulation for a 50-100% or 100-50% step load change)
Temperature Coefficient (Voltage)0.015% of max output voltage per °C (45 mV/°C)
Temperature Coefficient (Current)0.03% of max output current per °C
Voltage Programming ResolutionInfinite (continuous potentiometer control)
Current Programming ResolutionInfinite (continuous potentiometer control)
Operating ModesConstant Voltage (CV) and Constant Current (CC) with automatic crossover

Protection and Diagnostics

ParameterValue
Over Voltage Protection (OVP) RangeAdjustable from 30 to 330 Vdc (10% to 110% of maximum output voltage)
Over Voltage Protection TypeSCR Crowbar
Output Isolation Voltage to Chassis1000 Vdc maximum

Control and Interface

ParameterValue
Front Panel ControlsPower circuit breaker, fine and coarse voltage adjust, fine and coarse current adjust, OVP adjust
Analog Programming OptionsResistance programming (200 ohms/volt standard) or voltage programming
Remote Shutdown InputUnit shutdown circuit via rear terminal contact closure
Series Operation CapacityUp to 2 identical units connected in series (requires external protection diodes)
Parallel Operation CapacityMaster/slave parallel configuration up to 3 identical units
Panel Meter Accuracy2% of full scale

Environmental and Safety

ParameterValue
Storage Temperature Range-40 to +85 °C
Temperature DeratingLinearly derate output above 40 °C to 50% capacity at 70 °C
Cooling System (DCR 300-1.5B)Convection cooled
Cooling System (DCR 300-3B, 9B)Internal fan cooled

Physical Characteristics

ParameterValue
Form FactorBenchtop or Rackmount (model dependent)
Chassis Width19 inches (482.6 mm)
Chassis Height (DCR 300-1.5B)3U (5.25 inches / 133.3 mm)
Chassis Height (DCR 300-3B)3U (5.25 inches / 133.3 mm)
Chassis Height (DCR 300-9B)7U (12.25 inches / 311.0 mm)
Chassis Depth (DCR 300-1.5B)18.0 inches (457.0 mm)
Chassis Depth (DCR 300-3B)18.0 inches (457.0 mm)
Chassis Depth (DCR 300-9B)22.0 inches (559.0 mm)
Unit Weight (DCR 300-1.5B)40 lbs (18.1 kg)
Unit Weight (DCR 300-3B)65 lbs (29.5 kg)
Unit Weight (DCR 300-9B)190 lbs (86.2 kg)
DC Output ConnectionRear terminal strip only

AC Input Specifications

ParameterValue
Nominal AC Input (DCR 300-1.5B, 3B)115 Vac single-phase (103-127 Vac range)
Nominal AC Input (DCR 300-9B)208 Vac single-phase (187-229 Vac range)
AC Input Frequency Range57 to 63 Hz
AC Input ConnectionRear-mounted barrier strip

Remote Programming

ParameterValue
Voltage Programming Resistance1000 Ω/V

Front Panel Controls

ParameterValue
Voltage Control Type10-turn potentiometer
Current Control Type1-turn potentiometer

Performance & Stability

ParameterValue
Output Drift (Voltage)0.15% of maximum rated voltage over 8 hours
Output Drift (Current)0.5% of maximum rated current over 8 hours
Warm-Up Time30 minutes

AC Input

ParameterValue
AC Input Current (DCR 300-1.5B)6.5 A @ 115 VAC
AC Input Current (DCR 300-3B)11 A @ 115 VAC

Environmental

ParameterValue
Operating AltitudeUp to 10,000 ft (3,000 m)
Storage AltitudeUp to 40,000 ft (12,000 m)
Operating HumidityUp to 95% RH, non-condensing

Power Supply

ParameterValue
AC Input Phase (DCR 300-1.5B, 3B)Single-phase
AC Input Phase (DCR 300-9B)Single-phase

Performance

ParameterValue
Remote Voltage Programming Accuracy±1% of maximum output voltage
Remote Current Programming Accuracy±1% of maximum output current

Technology

SCR Phase Control with Passive LC Filter

Applications

Benchtop or Rackmount Programmable DC Power Supply