The Sorensen DCR40 series (part of the DCR-B family of phase-controlled power supplies) delivers stable, highly regulated, and adjustable DC power up to 40 VDC. Operating with high efficiency, these silicon-controlled rectifier (SCR) based supplies offer reliable performance in both constant-voltage and constant-current modes, featuring built-in over-voltage protection, remote sensing, and versatile remote programming options.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | Analog programming (standard); GPIB / IEEE-488 (optional via external programmer) |
| Display | Dual analog meters (voltage and current) |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 115 VAC / 208 VAC / 220 VAC / 230 VAC (model-dependent), single-phase, 57-63 Hz |
| Operating Temperature | 0 to +70 °C |
| Dimensions (W×H×D) | 241.3 x 133.4 x 457.2 mm (DCR40-13B) / 482.6 x 133.4 x 457.2 mm (DCR40-25B) / 482.6 x 177.8 x 508.0 mm (DCR40-70B) / 482.6 x 311.2 x 558.8 mm (DCR40-125B) (W×H×D) |
| Weight | 18.1 kg (DCR40-13B) / 34.0 kg (DCR40-25B) / 52.2 kg (DCR40-70B) / 102.1 kg (DCR40-125B) |
Output Specifications
| Parameter | Value |
|---|---|
| Rated Output Voltage Range | 0 - 40 VDC |
| Rated Output Current Range | 0-13 A (DCR 40-13B) / 0-25 A (DCR 40-25B) / 0-70 A (DCR 40-70B) / 0-125 A (DCR 40-125B) |
| Maximum Output Power | 520 W (DCR 40-13B) / 1000 W (DCR 40-25B) / 2800 W (DCR 40-70B) / 5000 W (DCR 40-125B) |
| Line Regulation (Voltage) | 0.05% of maximum rated voltage |
| Load Regulation (Voltage) | 0.05% of maximum rated voltage |
| Line Regulation (Current) | 0.25% of maximum rated current |
| Load Regulation (Current) | 0.25% of maximum rated current |
| Output Ripple (RMS) | 30 mV (DCR 40-13B) / 40 mV (DCR 40-25B & 40-70B) / 60 mV (DCR 40-125B) |
| Transient Recovery Time | 50 ms (typical) to return within 150 mV of steady-state voltage for a 50% load step |
| Temperature Coefficient (Voltage) | 0.015% per °C of maximum rated voltage |
| Temperature Coefficient (Current) | 0.03% per °C of maximum rated current |
| Drift (Stability over 8 Hours) | 0.1% of maximum output voltage (after 30-minute warm-up) |
| Operating Modes | Constant Voltage (CV) and Constant Current (CC) with automatic crossover |
AC Input Specifications
| Parameter | Value |
|---|---|
| Number of Phases | Single-phase |
| Input Frequency Range | 57 - 63 Hz (standard); 49 - 63 Hz (optional) |
Protection and Isolation
| Parameter | Value |
|---|---|
| Over-Voltage Protection (OVP) Range | 6 to 47 VDC |
| Output Isolation Voltage (to Chassis) | 150 VDC |
System Control and Connectivity
| Parameter | Value |
|---|---|
| Remote Sense Headroom | Up to 1.5 V drop per load lead (3 V total line drop) |
| Analog Programming Options | Resistance programming: 200 ohms/volt (standard) or 1000 ohms/volt (optional); Voltage programming: 1V/V |
| Series Configuration Limit | Up to 2 identical units |
| Parallel Configuration Limit | Multiple units (direct paralleling or master/slave configuration) |
| Remote On/Off Control | Yes (via rear terminal strip unit shutdown circuit) |
| Front Panel Controls | Power circuit breaker, coarse and fine voltage adjust potentiometers, coarse and fine current adjust potentiometers |
Environmental Specifications
| Parameter | Value |
|---|---|
| Storage Temperature Range | -40 to +85 °C |
| Operating Temperature Derating | Full rating to +40 °C; derate linearly to 50% current rating at +70 °C |
| Cooling Method | Convection cooled (DCR 40-13B and DCR 40-25B); Forced-air fan cooled (DCR 40-70B and DCR 40-125B) |
Physical Characteristics
| Parameter | Value |
|---|---|
| Form Factor | Rack-mountable or benchtop |
Power Requirements
| Parameter | Value |
|---|---|
| AC Input Voltage Tolerance | ±10% of nominal rating |
Connectivity
| Parameter | Value |
|---|---|
| Optional Digital Interface | GPIB (IEEE-488) control available via external programmer |
Front Panel Meters
| Parameter | Value |
|---|---|
| Analog Voltmeter Accuracy | ±2% of full scale |
| Analog Ammeter Accuracy | ±2% of full scale |
Analog Programming
| Parameter | Value |
|---|---|
| Voltage Programming Resistive Coefficient | 200 Ω/V (standard) / 1000 Ω/V (with Option M1) |
| Voltage Programming Current | 5 mA (standard) / 1 mA (with Option M1) |
Environmental
| Parameter | Value |
|---|---|
| Operating Humidity Range | 0% to 95% non-condensing |
Electrical Isolation
| Parameter | Value |
|---|---|
| Insulation Resistance | 50 MΩ minimum at 500 VDC (between input/output and chassis) |
Performance
| Parameter | Value |
|---|---|
| Duty Cycle | Continuous |
Technology
Phase-controlled SCR / Triac with passive LC filter
Applications