The Sorensen DCR40 series (part of the DCR-B family of phase-controlled power supplies) delivers stable, highly regulated, and adjustable DC power up to 40 VDC. Operating with high efficiency, these silicon-controlled rectifier (SCR) based supplies offer reliable performance in both constant-voltage and constant-current modes, featuring built-in over-voltage protection, remote sensing, and versatile remote programming options.

Specifications

General

ParameterValue
InterfacesAnalog programming (standard); GPIB / IEEE-488 (optional via external programmer)
DisplayDual analog meters (voltage and current)

Physical

ParameterValue
Power Supply115 VAC / 208 VAC / 220 VAC / 230 VAC (model-dependent), single-phase, 57-63 Hz
Operating Temperature0 to +70 °C
Dimensions (W×H×D)241.3 x 133.4 x 457.2 mm (DCR40-13B) / 482.6 x 133.4 x 457.2 mm (DCR40-25B) / 482.6 x 177.8 x 508.0 mm (DCR40-70B) / 482.6 x 311.2 x 558.8 mm (DCR40-125B) (W×H×D)
Weight18.1 kg (DCR40-13B) / 34.0 kg (DCR40-25B) / 52.2 kg (DCR40-70B) / 102.1 kg (DCR40-125B)

Output Specifications

ParameterValue
Rated Output Voltage Range0 - 40 VDC
Rated Output Current Range0-13 A (DCR 40-13B) / 0-25 A (DCR 40-25B) / 0-70 A (DCR 40-70B) / 0-125 A (DCR 40-125B)
Maximum Output Power520 W (DCR 40-13B) / 1000 W (DCR 40-25B) / 2800 W (DCR 40-70B) / 5000 W (DCR 40-125B)
Line Regulation (Voltage)0.05% of maximum rated voltage
Load Regulation (Voltage)0.05% of maximum rated voltage
Line Regulation (Current)0.25% of maximum rated current
Load Regulation (Current)0.25% of maximum rated current
Output Ripple (RMS)30 mV (DCR 40-13B) / 40 mV (DCR 40-25B & 40-70B) / 60 mV (DCR 40-125B)
Transient Recovery Time50 ms (typical) to return within 150 mV of steady-state voltage for a 50% load step
Temperature Coefficient (Voltage)0.015% per °C of maximum rated voltage
Temperature Coefficient (Current)0.03% per °C of maximum rated current
Drift (Stability over 8 Hours)0.1% of maximum output voltage (after 30-minute warm-up)
Operating ModesConstant Voltage (CV) and Constant Current (CC) with automatic crossover

AC Input Specifications

ParameterValue
Number of PhasesSingle-phase
Input Frequency Range57 - 63 Hz (standard); 49 - 63 Hz (optional)

Protection and Isolation

ParameterValue
Over-Voltage Protection (OVP) Range6 to 47 VDC
Output Isolation Voltage (to Chassis)150 VDC

System Control and Connectivity

ParameterValue
Remote Sense HeadroomUp to 1.5 V drop per load lead (3 V total line drop)
Analog Programming OptionsResistance programming: 200 ohms/volt (standard) or 1000 ohms/volt (optional); Voltage programming: 1V/V
Series Configuration LimitUp to 2 identical units
Parallel Configuration LimitMultiple units (direct paralleling or master/slave configuration)
Remote On/Off ControlYes (via rear terminal strip unit shutdown circuit)
Front Panel ControlsPower circuit breaker, coarse and fine voltage adjust potentiometers, coarse and fine current adjust potentiometers

Environmental Specifications

ParameterValue
Storage Temperature Range-40 to +85 °C
Operating Temperature DeratingFull rating to +40 °C; derate linearly to 50% current rating at +70 °C
Cooling MethodConvection cooled (DCR 40-13B and DCR 40-25B); Forced-air fan cooled (DCR 40-70B and DCR 40-125B)

Physical Characteristics

ParameterValue
Form FactorRack-mountable or benchtop

Power Requirements

ParameterValue
AC Input Voltage Tolerance±10% of nominal rating

Connectivity

ParameterValue
Optional Digital InterfaceGPIB (IEEE-488) control available via external programmer

Front Panel Meters

ParameterValue
Analog Voltmeter Accuracy±2% of full scale
Analog Ammeter Accuracy±2% of full scale

Analog Programming

ParameterValue
Voltage Programming Resistive Coefficient200 Ω/V (standard) / 1000 Ω/V (with Option M1)
Voltage Programming Current5 mA (standard) / 1 mA (with Option M1)

Environmental

ParameterValue
Operating Humidity Range0% to 95% non-condensing

Electrical Isolation

ParameterValue
Insulation Resistance50 MΩ minimum at 500 VDC (between input/output and chassis)

Performance

ParameterValue
Duty CycleContinuous

Technology

Phase-controlled SCR / Triac with passive LC filter

Applications

Industrial DC power, product burn-in testing, laboratory research, and automated test equipment (ATE) systems