The Sorensen DCR80 is a family of highly reliable, phase-controlled SCR programmable DC power supplies within the legacy DCR-B series, encompassing the DCR 80-4.5B, DCR 80-10B, and DCR 80-18B models. Designed for both benchtop and 19-inch rackmount applications, these robust units provide stable, regulated DC power up to 80 V with automatic crossover between Constant Voltage (CV) and Constant Current (CC) modes. They feature extensive remote analog control, remote sensing, and built-in overvoltage protection (OVP).

Specifications

General

ParameterValue
InterfacesAnalog remote programming (voltage and resistance); Remote shutdown; Remote sensing
DisplayDual analog meters for voltage and current (standard); 3.5-digit LED digital meters (Option M5)

Physical

ParameterValue
Power Supply115 VAC single-phase (standard), 208/220/230 VAC (optional); 57-63 Hz (standard), 47-53 Hz (optional)
Operating Temperature0 to 70 °C
Dimensions (W×H×D)89×483×394 mm (80-4.5B) / 133×483×394 mm (80-10B) / 178×483×508 mm (80-18B)
Weight18.1 kg (80-4.5B) / 29.5 kg (80-10B) / 40.8 kg (80-18B)

Output Specifications

ParameterValue
Rated Output Voltage0 to 80 VDC
Rated Output Current (DCR 80-4.5B)0 to 4.5 A
Rated Output Current (DCR 80-10B)0 to 10 A
Rated Output Current (DCR 80-18B)0 to 18 A
Maximum Output Power (DCR 80-4.5B)360 W
Maximum Output Power (DCR 80-10B)800 W
Maximum Output Power (DCR 80-18B)1440 W
Line Regulation (Voltage)±0.05% of maximum output voltage (40 mV) for a ±10% line change
Load Regulation (Voltage)±0.05% of maximum output voltage (40 mV) for a 0 to 100% load change
Line Regulation (Current)±0.15% of maximum output current for a ±10% line change
Load Regulation (Current)±0.15% of maximum output current for a 0 to 95% compliance voltage change
Output Ripple and Noise (RMS)150 mV RMS
Transient Recovery Time50 ms typical to return to within 1% of nominal output voltage for a 50% step load change
Temperature Coefficient (Voltage)0.015% of maximum output voltage per °C
Temperature Coefficient (Current)0.03% of maximum output current per °C
Maximum Remote Sense CompensationUp to 3 V total line drop (1.5 V per lead)
Output Drift (8 Hours)0.1% of maximum output voltage (after 30-minute warmup)
Operating ModesConstant Voltage (CV) and Constant Current (CC) with automatic crossover

AC Input Specifications

ParameterValue
AC Input Voltage Range115 VAC +10%/-13% standard (options for 208/220/230 VAC)
AC Input Frequency Range57 to 63 Hz standard (47 to 53 Hz optional via Option M11)
AC Input PhaseSingle-phase
AC Input Current (DCR 80-4.5B)9.5 A RMS maximum @ 115 VAC
AC Input Current (DCR 80-10B)16 A RMS maximum @ 115 VAC
AC Input Current (DCR 80-18B)26 A RMS maximum @ 115 VAC

Protection and Diagnostics

ParameterValue
Over Voltage Protection (OVP) Range10 to 90 VDC, adjustable via front-panel screwdriver potentiometer
Over Current ProtectionInherent continuous current limiting (adjustable from 0 to 100% of rated current)
Output Isolation Voltage (to Chassis)150 VDC maximum (either terminal may be grounded or floated up to this limit)
Unit Shutdown CircuitStandard shutdown circuit activated by OVP trip, over-temperature, or external signal

Control and Interface

ParameterValue
Analog Remote Programming (Voltage)1000 ohms per volt (standard) or 100 ohms per volt (optional)
Analog Remote Programming (Current)Resistive programming (resistance coefficient is model-dependent)
External Voltage Programming Ratio1:1 ratio (1 V output per 1 V programming voltage, or using series programming resistor)
Remote Shutdown / Enable InputYes, via contact closure or TTL-compatible voltage level
Parallel OperationMaster-slave parallel configuration supported
Series OperationSupported (up to a combined output voltage of 200 VDC or 300 VDC depending on isolation limit)

Environmental and Safety

ParameterValue
Operating Temperature DeratingContinuous operation at 100% rated current up to 40 °C, derating linearly to 50% rated current at 70 °C
Storage Temperature Range-40 to +85 °C
Cooling System (DCR 80-4.5B)Convection cooled
Cooling System (DCR 80-10B & 80-18B)Forced-air via internal fan

Physical Characteristics

ParameterValue
Form Factor19-inch rackmount or benchtop use
Chassis Height (DCR 80-4.5B)2U (3.5 in / 88.9 mm)
Chassis Height (DCR 80-10B)4U (7.0 in / 177.8 mm)
Chassis Height (DCR 80-18B)4U (7.0 in / 177.8 mm)
Chassis Width19.0 in / 482.6 mm
Chassis Depth (DCR 80-4.5B & 80-10B)15.5 in / 393.7 mm
Chassis Depth (DCR 80-18B)20.0 in / 508.0 mm
AC Input ConnectionsRear-panel barrier terminal strip

Analog Programming

ParameterValue
Remote Programming Resistance (Voltage)1000 Ω/V

Front Panel Controls

ParameterValue
Front Panel Voltage Control10-turn potentiometer
Front Panel Current Control1-turn potentiometer

Display & Meters

ParameterValue
Panel Meter TypeDual analog meters (standard); digital meters optional (Option M11)
Analog Meter Accuracy±2% of full scale

Environmental

ParameterValue
Operating AltitudeUp to 10,000 ft (3,000 m)
Non-Operating AltitudeUp to 40,000 ft (12,000 m)
Operating Humidity RangeUp to 95% RH (non-condensing)

Performance

ParameterValue
Output Ripple and Noise (Peak-to-Peak) (DCR 80-4.5B)400 mV
Output Ripple and Noise (Peak-to-Peak) (DCR 80-10B)400 mV
Output Ripple and Noise (Peak-to-Peak) (DCR 80-18B)400 mV
Warm-Up Time30 minutes

Programming & Control

ParameterValue
Remote Voltage Programming Resistance Constant1000 ohms/V

Controls & Indicators

ParameterValue
Front Panel Voltage Control Type10-turn potentiometer
Front Panel Current Control Type1-turn potentiometer

Technology

Phase-controlled SCR

Applications

Industrial burn-in, laboratory testing, system integration, and general-purpose DC power