The Sorensen DCR80 is a family of highly reliable, phase-controlled SCR programmable DC power supplies within the legacy DCR-B series, encompassing the DCR 80-4.5B, DCR 80-10B, and DCR 80-18B models. Designed for both benchtop and 19-inch rackmount applications, these robust units provide stable, regulated DC power up to 80 V with automatic crossover between Constant Voltage (CV) and Constant Current (CC) modes. They feature extensive remote analog control, remote sensing, and built-in overvoltage protection (OVP).
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | Analog remote programming (voltage and resistance); Remote shutdown; Remote sensing |
| Display | Dual analog meters for voltage and current (standard); 3.5-digit LED digital meters (Option M5) |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 115 VAC single-phase (standard), 208/220/230 VAC (optional); 57-63 Hz (standard), 47-53 Hz (optional) |
| Operating Temperature | 0 to 70 °C |
| Dimensions (W×H×D) | 89×483×394 mm (80-4.5B) / 133×483×394 mm (80-10B) / 178×483×508 mm (80-18B) |
| Weight | 18.1 kg (80-4.5B) / 29.5 kg (80-10B) / 40.8 kg (80-18B) |
Output Specifications
| Parameter | Value |
|---|---|
| Rated Output Voltage | 0 to 80 VDC |
| Rated Output Current (DCR 80-4.5B) | 0 to 4.5 A |
| Rated Output Current (DCR 80-10B) | 0 to 10 A |
| Rated Output Current (DCR 80-18B) | 0 to 18 A |
| Maximum Output Power (DCR 80-4.5B) | 360 W |
| Maximum Output Power (DCR 80-10B) | 800 W |
| Maximum Output Power (DCR 80-18B) | 1440 W |
| Line Regulation (Voltage) | ±0.05% of maximum output voltage (40 mV) for a ±10% line change |
| Load Regulation (Voltage) | ±0.05% of maximum output voltage (40 mV) for a 0 to 100% load change |
| Line Regulation (Current) | ±0.15% of maximum output current for a ±10% line change |
| Load Regulation (Current) | ±0.15% of maximum output current for a 0 to 95% compliance voltage change |
| Output Ripple and Noise (RMS) | 150 mV RMS |
| Transient Recovery Time | 50 ms typical to return to within 1% of nominal output voltage for a 50% step load change |
| Temperature Coefficient (Voltage) | 0.015% of maximum output voltage per °C |
| Temperature Coefficient (Current) | 0.03% of maximum output current per °C |
| Maximum Remote Sense Compensation | Up to 3 V total line drop (1.5 V per lead) |
| Output Drift (8 Hours) | 0.1% of maximum output voltage (after 30-minute warmup) |
| Operating Modes | Constant Voltage (CV) and Constant Current (CC) with automatic crossover |
AC Input Specifications
| Parameter | Value |
|---|---|
| AC Input Voltage Range | 115 VAC +10%/-13% standard (options for 208/220/230 VAC) |
| AC Input Frequency Range | 57 to 63 Hz standard (47 to 53 Hz optional via Option M11) |
| AC Input Phase | Single-phase |
| AC Input Current (DCR 80-4.5B) | 9.5 A RMS maximum @ 115 VAC |
| AC Input Current (DCR 80-10B) | 16 A RMS maximum @ 115 VAC |
| AC Input Current (DCR 80-18B) | 26 A RMS maximum @ 115 VAC |
Protection and Diagnostics
| Parameter | Value |
|---|---|
| Over Voltage Protection (OVP) Range | 10 to 90 VDC, adjustable via front-panel screwdriver potentiometer |
| Over Current Protection | Inherent continuous current limiting (adjustable from 0 to 100% of rated current) |
| Output Isolation Voltage (to Chassis) | 150 VDC maximum (either terminal may be grounded or floated up to this limit) |
| Unit Shutdown Circuit | Standard shutdown circuit activated by OVP trip, over-temperature, or external signal |
Control and Interface
| Parameter | Value |
|---|---|
| Analog Remote Programming (Voltage) | 1000 ohms per volt (standard) or 100 ohms per volt (optional) |
| Analog Remote Programming (Current) | Resistive programming (resistance coefficient is model-dependent) |
| External Voltage Programming Ratio | 1:1 ratio (1 V output per 1 V programming voltage, or using series programming resistor) |
| Remote Shutdown / Enable Input | Yes, via contact closure or TTL-compatible voltage level |
| Parallel Operation | Master-slave parallel configuration supported |
| Series Operation | Supported (up to a combined output voltage of 200 VDC or 300 VDC depending on isolation limit) |
Environmental and Safety
| Parameter | Value |
|---|---|
| Operating Temperature Derating | Continuous operation at 100% rated current up to 40 °C, derating linearly to 50% rated current at 70 °C |
| Storage Temperature Range | -40 to +85 °C |
| Cooling System (DCR 80-4.5B) | Convection cooled |
| Cooling System (DCR 80-10B & 80-18B) | Forced-air via internal fan |
Physical Characteristics
| Parameter | Value |
|---|---|
| Form Factor | 19-inch rackmount or benchtop use |
| Chassis Height (DCR 80-4.5B) | 2U (3.5 in / 88.9 mm) |
| Chassis Height (DCR 80-10B) | 4U (7.0 in / 177.8 mm) |
| Chassis Height (DCR 80-18B) | 4U (7.0 in / 177.8 mm) |
| Chassis Width | 19.0 in / 482.6 mm |
| Chassis Depth (DCR 80-4.5B & 80-10B) | 15.5 in / 393.7 mm |
| Chassis Depth (DCR 80-18B) | 20.0 in / 508.0 mm |
| AC Input Connections | Rear-panel barrier terminal strip |
Analog Programming
| Parameter | Value |
|---|---|
| Remote Programming Resistance (Voltage) | 1000 Ω/V |
Front Panel Controls
| Parameter | Value |
|---|---|
| Front Panel Voltage Control | 10-turn potentiometer |
| Front Panel Current Control | 1-turn potentiometer |
Display & Meters
| Parameter | Value |
|---|---|
| Panel Meter Type | Dual analog meters (standard); digital meters optional (Option M11) |
| Analog Meter Accuracy | ±2% of full scale |
Environmental
| Parameter | Value |
|---|---|
| Operating Altitude | Up to 10,000 ft (3,000 m) |
| Non-Operating Altitude | Up to 40,000 ft (12,000 m) |
| Operating Humidity Range | Up to 95% RH (non-condensing) |
Performance
| Parameter | Value |
|---|---|
| Output Ripple and Noise (Peak-to-Peak) (DCR 80-4.5B) | 400 mV |
| Output Ripple and Noise (Peak-to-Peak) (DCR 80-10B) | 400 mV |
| Output Ripple and Noise (Peak-to-Peak) (DCR 80-18B) | 400 mV |
| Warm-Up Time | 30 minutes |
Programming & Control
| Parameter | Value |
|---|---|
| Remote Voltage Programming Resistance Constant | 1000 ohms/V |
Controls & Indicators
| Parameter | Value |
|---|---|
| Front Panel Voltage Control Type | 10-turn potentiometer |
| Front Panel Current Control Type | 1-turn potentiometer |
Technology
Phase-controlled SCR
Applications
Industrial burn-in, laboratory testing, system integration, and general-purpose DC power