The Sorensen DCS33-33E is a highly reliable, 1089W programmable DC power supply designed for diverse development, testing, and system applications. Belonging to the Sorensen DCS (Direct Current Source) 1kW series, it features an ultra-low profile 1U chassis design, high power density, and built-in RS-232 and analog control interfaces, offering precise control over its 0-33V and 0-33A output ranges.
Specifications
General
| Parameter | Value |
|---|---|
| Display | Dual 3.5-digit LED digital meters for voltage and current readouts |
| Warm-up Time | 30 minutes |
| Warranty | 5 years |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 85-264 VAC, single-phase, 47-63 Hz (universal active PFC input) |
| Operating Temperature | 0 to 50 °C (derates linearly to 50% power from 50 °C to 70 °C) |
| Dimensions (W×H×D) | 482.6 mm × 44.4 mm × 444.5 mm |
| Weight | 8.6 kg |
Output Specifications
| Parameter | Value |
|---|---|
| Rated Output Voltage | 0 to 33 VDC |
| Rated Output Current | 0 to 33 ADC |
| Maximum Output Power | 1089 W |
| Line Regulation (Voltage) | 0.01% of max voltage + 2 mV |
| Line Regulation (Current) | 0.05% of max current |
| Load Regulation (Voltage) | 0.02% of max voltage + 5 mV |
| Load Regulation (Current) | 0.05% of max current |
| Output Ripple and Noise (RMS) | 10 mV |
| Output Ripple and Noise (Peak-to-Peak) | 80 mV |
| Transient Recovery Time | < 1 ms (for 50% to 100% or 100% to 50% load change to within 100 mV of nominal) |
| Temperature Coefficient (Voltage) | 0.02% of max voltage per °C |
| Temperature Coefficient (Current) | 0.03% of max current per °C |
| Maximum Remote Sense Compensation | 1 V per line |
AC Input Specifications
| Parameter | Value |
|---|---|
| Efficiency (Full Load) | 82% typical |
| Power Factor (Full Load) | 0.99 typical |
| Maximum AC Input Current | 13.5 A @ 115 VAC, 7 A @ 230 VAC |
Protection and Diagnostics
| Parameter | Value |
|---|---|
| Over Voltage Protection (OVP) Range | 1 V to 37 V (adjustable) |
| Foldback Protection Mode | Shutdown on transition from CV to CC or CC to CV mode (user selectable) |
| Output Isolation Voltage (to Chassis) | 125 VDC |
Control and Interface
| Parameter | Value |
|---|---|
| Programming Accuracy (Analog Voltage) | ±0.5% of max output voltage |
| Programming Accuracy (Analog Current) | ±1.0% of max output current |
| Analog Programming Input Ranges | 0-5 V, 0-10 V, or 0-5k / 0-10k ohms resistively (selectable) |
Environmental and Safety
| Parameter | Value |
|---|---|
| Storage Temperature Range | -55 to +85 °C |
| Operating Humidity Range | 0% to 90% RH, non-condensing |
| Cooling System | Internal fan (airflow from front and sides, exhaust at rear) |
| Compliance Standards | CE Mark, FCC Part 15 Class A |
Physical Characteristics
| Parameter | Value |
|---|---|
| Form Factor | 1U Rackmount |
| Chassis Width | 19 inches |
| Chassis Height | 1.75 inches (1U) |
| Chassis Depth | 17.5 inches |
Programming & Control
| Parameter | Value |
|---|---|
| Analog Programming Voltage Range | 0-5 V / 0-10 V (selectable) |
| Analog Programming Resistive Range | 0-5 kΩ / 0-10 kΩ (selectable) |
| Remote Shutdown | TTL compatible (active high or low) or dry contact closure |
| Parallel Operation | Up to 4 identical units in Master/Slave configuration |
| Series Operation | Up to 2 identical units |
Output Parameters
| Parameter | Value |
|---|---|
| Output Rise Time (Full Load) | 80 ms |
| Output Fall Time (Full Load) | 80 ms |
| Output Drift (8 Hours) | 0.03% of max output voltage / 0.03% of max output current |
Protection
| Parameter | Value |
|---|---|
| Over-Temperature Protection (OTP) | Automatic shutdown |
AC Input
| Parameter | Value |
|---|---|
| Input Phase | Single phase |
| Input Frequency Range | 47 - 63 Hz |
Front Panel Controls & Indicators
| Parameter | Value |
|---|---|
| Voltage/Current Control | 10-turn potentiometers |
| Digital Meter Resolution | 3.5 digits |
| Digital Meter Accuracy | 0.5% of maximum rating ± 1 count |
Programming & Monitoring
| Parameter | Value |
|---|---|
| Analog Monitor Voltage Range | 0 - 10 V (or 0 - 5 V selectable) |
Operational Features
| Parameter | Value |
|---|---|
| Parallel Connection Capacity | Up to 4 units |
| Series Connection Capacity | Up to 2 units |
Technology
Switch-mode programmable DC power supply
Applications
Automated Test Equipment (ATE), laboratory R&D, product burn-in, battery charging, and semiconductor testing