The Sorensen DCS33-33E is a highly reliable, 1089W programmable DC power supply designed for diverse development, testing, and system applications. Belonging to the Sorensen DCS (Direct Current Source) 1kW series, it features an ultra-low profile 1U chassis design, high power density, and built-in RS-232 and analog control interfaces, offering precise control over its 0-33V and 0-33A output ranges.

Specifications

General

ParameterValue
DisplayDual 3.5-digit LED digital meters for voltage and current readouts
Warm-up Time30 minutes
Warranty5 years

Physical

ParameterValue
Power Supply85-264 VAC, single-phase, 47-63 Hz (universal active PFC input)
Operating Temperature0 to 50 °C (derates linearly to 50% power from 50 °C to 70 °C)
Dimensions (W×H×D)482.6 mm × 44.4 mm × 444.5 mm
Weight8.6 kg

Output Specifications

ParameterValue
Rated Output Voltage0 to 33 VDC
Rated Output Current0 to 33 ADC
Maximum Output Power1089 W
Line Regulation (Voltage)0.01% of max voltage + 2 mV
Line Regulation (Current)0.05% of max current
Load Regulation (Voltage)0.02% of max voltage + 5 mV
Load Regulation (Current)0.05% of max current
Output Ripple and Noise (RMS)10 mV
Output Ripple and Noise (Peak-to-Peak)80 mV
Transient Recovery Time< 1 ms (for 50% to 100% or 100% to 50% load change to within 100 mV of nominal)
Temperature Coefficient (Voltage)0.02% of max voltage per °C
Temperature Coefficient (Current)0.03% of max current per °C
Maximum Remote Sense Compensation1 V per line

AC Input Specifications

ParameterValue
Efficiency (Full Load)82% typical
Power Factor (Full Load)0.99 typical
Maximum AC Input Current13.5 A @ 115 VAC, 7 A @ 230 VAC

Protection and Diagnostics

ParameterValue
Over Voltage Protection (OVP) Range1 V to 37 V (adjustable)
Foldback Protection ModeShutdown on transition from CV to CC or CC to CV mode (user selectable)
Output Isolation Voltage (to Chassis)125 VDC

Control and Interface

ParameterValue
Programming Accuracy (Analog Voltage)±0.5% of max output voltage
Programming Accuracy (Analog Current)±1.0% of max output current
Analog Programming Input Ranges0-5 V, 0-10 V, or 0-5k / 0-10k ohms resistively (selectable)

Environmental and Safety

ParameterValue
Storage Temperature Range-55 to +85 °C
Operating Humidity Range0% to 90% RH, non-condensing
Cooling SystemInternal fan (airflow from front and sides, exhaust at rear)
Compliance StandardsCE Mark, FCC Part 15 Class A

Physical Characteristics

ParameterValue
Form Factor1U Rackmount
Chassis Width19 inches
Chassis Height1.75 inches (1U)
Chassis Depth17.5 inches

Programming & Control

ParameterValue
Analog Programming Voltage Range0-5 V / 0-10 V (selectable)
Analog Programming Resistive Range0-5 kΩ / 0-10 kΩ (selectable)
Remote ShutdownTTL compatible (active high or low) or dry contact closure
Parallel OperationUp to 4 identical units in Master/Slave configuration
Series OperationUp to 2 identical units

Output Parameters

ParameterValue
Output Rise Time (Full Load)80 ms
Output Fall Time (Full Load)80 ms
Output Drift (8 Hours)0.03% of max output voltage / 0.03% of max output current

Protection

ParameterValue
Over-Temperature Protection (OTP)Automatic shutdown

AC Input

ParameterValue
Input PhaseSingle phase
Input Frequency Range47 - 63 Hz

Front Panel Controls & Indicators

ParameterValue
Voltage/Current Control10-turn potentiometers
Digital Meter Resolution3.5 digits
Digital Meter Accuracy0.5% of maximum rating ± 1 count

Programming & Monitoring

ParameterValue
Analog Monitor Voltage Range0 - 10 V (or 0 - 5 V selectable)

Operational Features

ParameterValue
Parallel Connection CapacityUp to 4 units
Series Connection CapacityUp to 2 units

Technology

Switch-mode programmable DC power supply

Applications

Automated Test Equipment (ATE), laboratory R&D, product burn-in, battery charging, and semiconductor testing