The Sorensen DHP 60-110 (by AMETEK) is a programmable, high-power DC switching power supply designed for demanding test and measurement applications. Offering a modular profile design, it delivers up to 60V and 110A (6.6 kW) of precise, stable DC power. It features advanced digital metering and diagnostics—including AC input voltage and air inlet temperature monitoring—along with extensive system protection features and power-off memory recovery.

Specifications

General

ParameterValue
InterfacesAnalog, RS-232 (Standard); GPIB / IEEE-488 (Optional)
DisplayDigital Displays for output power, voltage, current, set points, AC input, air inlet temperature, and diagnostics

Physical

ParameterValue
Power Supply3-Phase AC input (e.g., 208 / 380 / 400 / 480 VAC configuration dependent), 47 - 63 Hz
Operating Temperature0 to 50 °C
Chassis Height3U

Output Specifications

ParameterValue
Rated Output Voltage0 - 60 VDC
Rated Output Current0 - 110 ADC
Maximum Output Power6600 W (6.6 kW)
Constant Voltage ModeYes
Constant Current ModeYes

AC Input Specifications

ParameterValue
AC Input Phase Configuration3-Phase, 3-wire plus ground
AC Input Frequency Range47 - 63 Hz

Protection and System Functionality

ParameterValue
Over-Voltage Protection (OVP)Yes
Over-Current Protection (OCP)Yes
Over-Temperature Protection (OTP)Yes
Surge Limit ProtectionYes
Soft Start ProtectionYes
Brown Out ProtectionYes
Short Circuit ProtectionYes
External ShutdownYes (Inhibits output via external control)
Front Panel LockoutYes (Disables most front panel controls during remote operation)
Power-Off MemoryYes (Restores settings by pushing LAST SET button when input power is enabled)

Control and Communication Interfaces

ParameterValue
Up/Down Arrow ControlsYes (Controls voltages, step changes, and current)
Power Supply Rating DisplayYes
Output Power MeteringYes (Displays present output power)
Output Voltage/Current MeteringYes (Displays present output voltage and current)
Set Point and Limit MeteringYes (Displays all power, voltage, and current set points and limits)
AC Input Voltage MonitoringYes (Displays present and highest AC input voltage)
Air Inlet Temperature MonitoringYes (Displays present and highest air inlet temperature)
Auto-Step Sequence Settings DisplayYes
Calibration Set-Up DisplayYes
Remote Operation Set-Up DisplayYes
Diagnostics Fault Status SummaryYes

Physical and Mechanical

ParameterValue
Chassis DesignModular design (three rackmount profiles based on output power)

Power Requirements

ParameterValue
AC Input Voltage Options208 VAC / 380 VAC / 400 VAC / 480 VAC (three-phase, option dependent)

Environmental

ParameterValue
Cooling SystemForced air cooling, front intake, rear exhaust
Storage Temperature Range-40 °C to +85 °C

Performance

ParameterValue
Remote Sense CompensationUp to 5 V total line drop
Stability0.05% of maximum rated output over 8 hours (after 30-minute warm-up)
Voltage Temperature Coefficient0.02% of maximum rated output voltage per °C
Current Temperature Coefficient0.03% of maximum rated output current per °C

Regulation

ParameterValue
Voltage Line Regulation0.1% of rated output voltage
Voltage Load Regulation0.1% of rated output voltage
Current Line Regulation0.1% of rated output current
Current Load Regulation0.1% of rated output current

Programming & Control

ParameterValue
Analog Programming Input Options0-5 V, 0-10 V, 0-5 kΩ, or 0-10 kΩ (user selectable)

Power Specification

ParameterValue
Typical Efficiency> 85% at full load

Technology

Switching

Applications

Programmable DC Power Supply