- Home
- Categories
- Test equipment
- Power Supplies
- Sorensen
- XT Series - 60W
The Sorensen (Ametek) XT Series is a 60-watt programmable linear DC power supply designed for benchtop and system integration applications. Featuring very low noise and ripple, excellent line and load regulation, and fast transient response, the XT Series provides high-performance, clean linear power in a compact quarter-rack package.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | Analog programming (standard); GPIB (via optional M9B card), RS-232 (via optional M9C card) |
| Display | Dual 3.5-digit LED digital meters for voltage and current |
Physical
| Parameter | Value |
|---|---|
| Operating Temperature | 0 to 50 °C |
| Dimensions (W×H×D) | 107 mm × 132 mm × 297 mm |
| Weight | 4.3 kg |
Output Specifications
| Parameter | Value |
|---|---|
| Maximum Output Power | 60 W |
| Output Modes | Constant Voltage (CV) or Constant Current (CC) |
| Line Regulation (Voltage) | 0.01% + 2 mV |
| Line Regulation (Current) | 0.01% + 2 mA |
| Load Regulation (Voltage) | 0.01% + 2 mV |
| Load Regulation (Current) | 0.01% + 2 mA |
| Output Ripple and Noise (Voltage) | 1 mV RMS |
| Output Ripple and Noise (Current) | 2 mA RMS |
| Transient Recovery Time | < 50 µs to within 15 mV of nominal following a 50% to 100% load change |
| Maximum Remote Sense Compensation | 0.5 V per lead (1.0 V total) |
Control & Interface
| Parameter | Value |
|---|---|
| Series/Parallel Configuration Capacity | Series or parallel connection of multiple units is supported |
Physical Characteristics
| Parameter | Value |
|---|---|
| Form Factor | Quarter-rack wide, benchtop or rack-mountable |
Environmental and Safety
| Parameter | Value |
|---|---|
| Safety Agency Approvals | CSA certified to CSA C22.2 No. 1010.1, CE marked |
| Cooling System | Convection cooled |
Model Configurations
| Parameter | Value |
|---|---|
| XT 15-4 Output Rating | 0-15 V, 0-4 A |
| XT 20-3 Output Rating | 0-20 V, 0-3 A |
| XT 30-2 Output Rating | 0-30 V, 0-2 A |
| XT 60-1 Output Rating | 0-60 V, 0-1 A |
| XT 120-0.5 Output Rating | 0-120 V, 0-0.5 A |
| XT 250-0.25 Output Rating | 0-250 V, 0-0.25 A |
Power Requirements
| Parameter | Value |
|---|---|
| AC Input Voltage Range | 115 VAC ±10% (standard); 100, 220, 230, 240 VAC options |
| AC Input Frequency Range | 47-63 Hz |
Environmental
| Parameter | Value |
|---|---|
| Storage Temperature Range | -40°C to +85°C |
Safety & Isolation
| Parameter | Value |
|---|---|
| Output Isolation to Chassis | 300 VDC maximum |
Options
| Parameter | Value |
|---|---|
| Digital Programming Interface Options | M9B (GPIB), M9C (RS-232) |
Controls
| Parameter | Value |
|---|---|
| Front Panel Controls | 10-turn voltage and current potentiometers |
Power Input
| Parameter | Value |
|---|---|
| Maximum Input Current | 1.2 A RMS @ 115 VAC / 0.6 A RMS @ 230 VAC |
Display & Metering
| Parameter | Value |
|---|---|
| Voltage Meter Accuracy | ±(0.5% of reading + 1 digit) |
| Current Meter Accuracy | ±(0.5% of reading + 1 digit) |
Operation
| Parameter | Value |
|---|---|
| Warm-up Time | 30 minutes |
Technology
Linear
Applications
Benchtop & System Programmable DC Power
Looking for the orensen (Ametek) XT Series - 60W?
Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.
Selling this kind of equipment? Sell with us