The Tektronix 1503C is a highly accurate, portable Metallic Time-Domain Reflectometer (TDR) designed for locating faults and structural anomalies in metallic cables. Featuring a durable field-ready chassis, the 1503C is optimized for testing coaxial, twisted-pair, and parallel cables over long ranges. With a dynamic horizontal testing range extending up to 50,000 feet (15,230 meters), the instrument uses a high-resolution dot-matrix liquid crystal display (LCD) to present detailed impedance signatures. It supports both AC power and a high-capacity internal lead-gel battery for flexible field operations. Optional expansion modules, such as a front-panel dot-matrix strip chart recorder, allow operators to easily record and document cable diagnostics in real time.

Specifications

General

ParameterValue
DisplayHigh-resolution dot-matrix liquid crystal display (LCD) with electroluminescent (EL) backlight

Physical

ParameterValue
Operating Temperature-15°C to +55°C

Signal and Pulse Characteristics

ParameterValue
Pulse Widths2 ns to 1000 ns
Pulse Shape1/2 sine
Maximum Distance Range50,000 ft (15,230 m)
Propagation Velocity (Vp) Range0.300 to 0.999
Vp Setting Resolution0.001

Receiver and Horizontal System

ParameterValue
Horizontal Range0 to 50,000 ft (0 to 10,000 m)

Display and User Interface

ParameterValue
Primary Distance Readout UnitsFeet or Meters (selectable)

Applications

ParameterValue
Supported Cable TypesCoaxial, twisted pair, or parallel cable
Fault Detection CapabilitiesShorts, opens, defects in the shield, foreign substances (e.g. water), kinks

Connectivity, I/O, and Storage

ParameterValue
Optional PrinterDot matrix strip chart recorder (installs into front-panel Option Port)

Power Supply and Battery System

ParameterValue
Internal Battery ChemistryLead-gel

Physical and Environmental

ParameterValue
Storage Temperature Range-62°C to +85°C

Measurement Specifications

ParameterValue
Maximum Input Protection400 V (DC + peak AC)

Power Requirements

ParameterValue
AC Input Voltage Ranges90 to 130 VAC, 180 to 250 VAC
AC Input Frequency Range45 Hz to 440 Hz

Environmental & Compliance

ParameterValue
Environmental ComplianceDesigned to meet MIL-T-28800D, Class 3, Style C
Operating Altitude Limit15,000 ft (4,572 m)
Non-Operating Altitude Limit50,000 ft (15,240 m)

Inputs & Outputs

ParameterValue
Front Panel Output ConnectorBNC female

Environmental

ParameterValue
Environmental Compliance StandardMIL-T-28800D, Type III, Class 3, Style C (drip-proof)

Technology

Metallic Time Domain Reflectometer (TDR)

Applications

Telecommunications, Datacom, and Metallic Cable Fault Diagnostics