The Tektronix 2712 is a classic, high-value swept spectrum analyzer designed for RF analysis up to 1.8 GHz. Combining a 4-trace digital storage display with a true analog real-time display, it offers robust capabilities for bench and field use, including an internal frequency counter, built-in preamplifier, and optional tracking generator and quasi-peak detector for EMC measurements.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GPIB (optional), RS-232 (optional) |
| Display | 9-inch CRT, 4 Trace Digital Plus True Analog Display |
| User Input | Dedicated numeric keypad and logically grouped menu keys |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 90 to 250 VAC, 48 to 440 Hz |
| Operating Temperature | 0 to +50 °C |
| Dimensions (W×H×D) | 361 × 137 × 445 mm |
| Weight | 9.5 kg (approx 21 lbs) |
Frequency
| Parameter | Value |
|---|---|
| Frequency Range | 9 kHz to 1.8 GHz |
| Frequency Reference Accuracy | 1 × 10^-5 (10 ppm) (standard), 5 × 10^-7 (0.5 ppm) (with Option 14) |
| Resolution Bandwidth (RBW) Range | 300 Hz to 5 MHz (in 1-3 sequence) |
| Video Bandwidth (VBW) Range | 3 Hz to 300 kHz |
| Frequency Span Range | Zero span, 1 kHz/div to 180 MHz/div, Max span (1.8 GHz) |
| Internal Frequency Counter | Standard built-in |
| Frequency Span Modes | Max Span (1.800 GHz), Zero Span, and Variable Span (1 kHz/div to 180 MHz/div) |
Amplitude & Sensitivity
| Parameter | Value |
|---|---|
| Displayed Average Noise Level (DANL) | -139 dBm (-92 dBmV) with built-in preamp |
| RF Input Impedance | 50 Ohms (75 Ohms optional) |
| RF Input Connector Type | Type N female |
| Maximum DC Input Voltage | 100 V |
| Maximum Safe RF Input Level | +20 dBm continuous (with minimum 10 dB attenuation) |
Memory & Processing
| Parameter | Value |
|---|---|
| Internal Memory (RAM) | 124 KB |
Measurement Modes & Analysis
| Parameter | Value |
|---|---|
| EMC Measurements | Supported with optional Quasi-peak detector |
| Swept Measurements | Up to 1.8 GHz (with optional internal or external tracking generator) |
RF Input
| Parameter | Value |
|---|---|
| RF Input Impedance Options | 50 Ω (standard), 75 Ω (with Option 12) |
Amplitude
| Parameter | Value |
|---|---|
| RF Attenuation Range | 0 to 50 dB in 10 dB steps |
| Vertical Scale Factors | 10 dB/div, 5 dB/div, 1 dB/div, and Linear |
| Reference Level Range | -110 dBm to +20 dBm (50 Ω) |
Sweep
| Parameter | Value |
|---|---|
| Sweep Time Range | 50 µs/div to 2 s/div (in 1-2-5 sequence), zoom down to 1 µs/div in Zero Span |
Performance
| Parameter | Value |
|---|---|
| Phase Noise (SSB) | -70 dBc/Hz at 10 kHz offset |
Tracking Generator (Option 04)
| Parameter | Value |
|---|---|
| Tracking Generator Frequency Range | 100 kHz to 1.8 GHz (with Option 04) |
| Tracking Generator Output Level | 0 dBm to -48 dBm in 1 dB steps (with Option 04) |
Memory & Storage
| Parameter | Value |
|---|---|
| Stored Waveform Memory | Up to 108 non-volatile waveforms |
| Stored Instrument Setups | Up to 108 non-volatile front-panel setups |
Amplitude Accuracy
| Parameter | Value |
|---|---|
| Frequency Response | ±1.5 dB (9 kHz to 1.8 GHz, referenced to 100 MHz, 10 dB RF attenuation) |
| Absolute Amplitude Accuracy | ±0.4 dB (at 100 MHz, -20 dBm reference level, 10 dB RF attenuation, 3 MHz RBW, 20 °C to 30 °C) |
| Log Scale Fidelity | ±1.0 dB per 10 dB, up to ±2.0 dB maximum cumulative error over 80 dB range |
| Linear Scale Fidelity | ±5% of full scale |
Spurious & Distortion
| Parameter | Value |
|---|---|
| Third-Order Intermodulation Distortion | -70 dBc or lower (for two -30 dBm signals at input mixer) |
| Second Harmonic Distortion | -70 dBc or lower (for a -40 dBm signal at input mixer) |
| Residual Responses | -100 dBm or lower (with 0 dB RF attenuation, terminated input, 9 kHz to 1.8 GHz) |
| LO Emissions at RF Input | -70 dBm or lower (with 0 dB RF attenuation) |
Sweep & Trigger
| Parameter | Value |
|---|---|
| Trigger Modes | Free Run, Internal, Line, External, Single Sweep, TV Line, TV Field |
Inputs & Outputs
| Parameter | Value |
|---|---|
| Calibrator Output | -20 dBm ±0.3 dB at 100 MHz |
Display
| Parameter | Value |
|---|---|
| Display Resolution | 512 horizontal x 256 vertical points |
Technology
Superheterodyne / Swept-Tuned
Applications
RF Analysis, EMC Testing, Signal Monitoring