The Tektronix 2712 is a classic, high-value swept spectrum analyzer designed for RF analysis up to 1.8 GHz. Combining a 4-trace digital storage display with a true analog real-time display, it offers robust capabilities for bench and field use, including an internal frequency counter, built-in preamplifier, and optional tracking generator and quasi-peak detector for EMC measurements.

Specifications

General

ParameterValue
InterfacesGPIB (optional), RS-232 (optional)
Display9-inch CRT, 4 Trace Digital Plus True Analog Display
User InputDedicated numeric keypad and logically grouped menu keys

Physical

ParameterValue
Power Supply90 to 250 VAC, 48 to 440 Hz
Operating Temperature0 to +50 °C
Dimensions (W×H×D)361 × 137 × 445 mm
Weight9.5 kg (approx 21 lbs)

Frequency

ParameterValue
Frequency Range9 kHz to 1.8 GHz
Frequency Reference Accuracy1 × 10^-5 (10 ppm) (standard), 5 × 10^-7 (0.5 ppm) (with Option 14)
Resolution Bandwidth (RBW) Range300 Hz to 5 MHz (in 1-3 sequence)
Video Bandwidth (VBW) Range3 Hz to 300 kHz
Frequency Span RangeZero span, 1 kHz/div to 180 MHz/div, Max span (1.8 GHz)
Internal Frequency CounterStandard built-in
Frequency Span ModesMax Span (1.800 GHz), Zero Span, and Variable Span (1 kHz/div to 180 MHz/div)

Amplitude & Sensitivity

ParameterValue
Displayed Average Noise Level (DANL)-139 dBm (-92 dBmV) with built-in preamp
RF Input Impedance50 Ohms (75 Ohms optional)
RF Input Connector TypeType N female
Maximum DC Input Voltage100 V
Maximum Safe RF Input Level+20 dBm continuous (with minimum 10 dB attenuation)

Memory & Processing

ParameterValue
Internal Memory (RAM)124 KB

Measurement Modes & Analysis

ParameterValue
EMC MeasurementsSupported with optional Quasi-peak detector
Swept MeasurementsUp to 1.8 GHz (with optional internal or external tracking generator)

RF Input

ParameterValue
RF Input Impedance Options50 Ω (standard), 75 Ω (with Option 12)

Amplitude

ParameterValue
RF Attenuation Range0 to 50 dB in 10 dB steps
Vertical Scale Factors10 dB/div, 5 dB/div, 1 dB/div, and Linear
Reference Level Range-110 dBm to +20 dBm (50 Ω)

Sweep

ParameterValue
Sweep Time Range50 µs/div to 2 s/div (in 1-2-5 sequence), zoom down to 1 µs/div in Zero Span

Performance

ParameterValue
Phase Noise (SSB)-70 dBc/Hz at 10 kHz offset

Tracking Generator (Option 04)

ParameterValue
Tracking Generator Frequency Range100 kHz to 1.8 GHz (with Option 04)
Tracking Generator Output Level0 dBm to -48 dBm in 1 dB steps (with Option 04)

Memory & Storage

ParameterValue
Stored Waveform MemoryUp to 108 non-volatile waveforms
Stored Instrument SetupsUp to 108 non-volatile front-panel setups

Amplitude Accuracy

ParameterValue
Frequency Response±1.5 dB (9 kHz to 1.8 GHz, referenced to 100 MHz, 10 dB RF attenuation)
Absolute Amplitude Accuracy±0.4 dB (at 100 MHz, -20 dBm reference level, 10 dB RF attenuation, 3 MHz RBW, 20 °C to 30 °C)
Log Scale Fidelity±1.0 dB per 10 dB, up to ±2.0 dB maximum cumulative error over 80 dB range
Linear Scale Fidelity±5% of full scale

Spurious & Distortion

ParameterValue
Third-Order Intermodulation Distortion-70 dBc or lower (for two -30 dBm signals at input mixer)
Second Harmonic Distortion-70 dBc or lower (for a -40 dBm signal at input mixer)
Residual Responses-100 dBm or lower (with 0 dB RF attenuation, terminated input, 9 kHz to 1.8 GHz)
LO Emissions at RF Input-70 dBm or lower (with 0 dB RF attenuation)

Sweep & Trigger

ParameterValue
Trigger ModesFree Run, Internal, Line, External, Single Sweep, TV Line, TV Field

Inputs & Outputs

ParameterValue
Calibrator Output-20 dBm ±0.3 dB at 100 MHz

Display

ParameterValue
Display Resolution512 horizontal x 256 vertical points

Technology

Superheterodyne / Swept-Tuned

Applications

RF Analysis, EMC Testing, Signal Monitoring