The Tektronix 80E04 is a high-performance, 2-channel electrical sampling module featuring Time Domain Reflectometry (TDR) capabilities. Designed for use with Tektronix Digital Serial Analyzers and Communications Signal Analyzers, it provides a 20 GHz analog bandwidth and a rapid TDR step rise time, making it ideal for impedance characterization, crosstalk analysis, and high-speed signal integrity measurements.

Specifications

General

ParameterValue
InterfacesProprietary 80-pin mainframe interface, 2x 3.5 mm female RF connectors
DisplayNone (uses host mainframe display)
Standard AccessoriesTwo SMA 50 Ω terminations, two SMA shorts, anti-static wrist strap, calibration certificate

Physical

ParameterValue
Power SupplyPowered directly by the host mainframe
Operating Temperature10 °C to 40 °C
Dimensions (W×H×D)79 mm × 25 mm × 135 mm
Weight0.4 kg

Signal Acquisition (Vertical System)

ParameterValue
Number of Channels2
Analog Bandwidth20 GHz
Calculated Rise Time (10% to 90%)17.5 ps
Calculated Rise Time (20% to 80%)12.0 ps
RMS Noise (Typical)600 µV
RMS Noise (Maximum)1.2 mV
Dynamic Range1.0 V p-p
Offset Range±1.6 V
Vertical Scale Range1 mV/div to 100 mV/div
DC Gain Accuracy±1.0% of full scale

TDR / TDT Step Generator

ParameterValue
TDR Channels2
TDR Step Rise Time (10% to 90%, Typical)28 ps
TDR Step Rise Time (10% to 90%, Maximum)35 ps
TDR Step Amplitude250 mV (nominal, each channel)
Step Polarity ConfigurationsPositive or negative (selectable independently per channel)
TDR Step Repetition Rate25 kHz to 300 kHz (selectable)
TDT CapabilitySupported (using dual-channel configuration)

Input Characteristics & Port Specifications

ParameterValue
Input Connector Type3.5 mm female
Input Impedance50 Ω ± 1 Ω
Maximum Non-destructive Input Voltage±2.0 V (DC + peak AC)

Host Mainframe Compatibility & Control

ParameterValue
Compatible MainframesTektronix DSA8300, DSA8200, CSA8200, CSA8000, TDS8200, TDS8000
Slot Width Requirement1 slot

Physical Characteristics

ParameterValue
Width79 mm
Height25 mm
Depth135 mm

Environmental & Compliance

ParameterValue
Operating Temperature Range10 °C to 40 °C
Non-Operating Temperature Range-22 °C to 60 °C
Operating Humidity Range20% to 80% RH (non-condensing)

TDR Performance

ParameterValue
TDR Step Aberrations (First 300 ps)+10%, -5% or less (typical)
TDR Step Aberrations (300 ps to 5 ns)±3% or less (typical)
TDR Step Aberrations (After 5 ns)±1% or less (typical)

Horizontal System

ParameterValue
Horizontal Deskew Range±250 ps

Electrical Characteristics

ParameterValue
DC Input Resistance Tolerance±0.5 Ω
Channel-to-Channel Isolation≥60 dB at 10 GHz, ≥50 dB at 20 GHz (typical)

Environmental

ParameterValue
Maximum Operating Altitude3000 m
Maximum Non-Operating Altitude12190 m
Operating Vibration0.33 GRMS (5 Hz to 500 Hz)
Non-Operating Vibration2.24 GRMS (5 Hz to 500 Hz)

Vertical System

ParameterValue
Maximum Operating Input Voltage1.0 V p-p
DC Input Resistance50 Ω ± 0.5 Ω

TDR System

ParameterValue
TDR Step Source Impedance50 Ω ± 1 Ω
TDR Step Delay Range-500 ps to +1000 ps

Technology

Electrical Sampling & Time Domain Reflectometry (TDR)

Applications

High-speed interconnect characterization, differential impedance measurements, and signal integrity testing