The Tektronix AFG310 is a 16 MHz Arbitrary Function Generator featuring standard waveforms, built-in custom arbitrary waveform editing, and the ability to download waveforms directly from Tektronix digital oscilloscopes. With its 12-bit vertical resolution, 16 MS/s sample rate, and built-in modulation and sweep capabilities, it serves as a highly versatile signal source for engineering laboratories and system applications.

Specifications

General

ParameterValue
InterfacesGPIB (IEEE-488.2)
DisplayBacklit LCD
Warm-up Time20 minutes

Physical

ParameterValue
Power Supply90 to 250 V AC, 48 to 63 Hz, 50 W max
Operating Temperature0 °C to +50 °C
Dimensions (W×H×D)310 mm × 99 mm × 373 mm
Weight4.4

Channel Characteristics

ParameterValue
Number of Channels1
Operating ModesContinuous, Triggered, Gated, Burst, Sweep, Modulation

Waveform Generation

ParameterValue
Standard WaveformsSine, Square, Triangle, Ramp, Pulse, DC, Noise
Arbitrary Waveform Memory4 user waveforms of 16,384 points each
Vertical Resolution12 bits
Sampling Rate16 MS/s
User Waveform PresetsUSR1: Sin (X)/X, USR2: Double Exponential Pulse, USR3: Damped Sine Wave, USR4: NRZ Random Signal

Frequency Specifications

ParameterValue
Sine Frequency Range10 mHz to 16 MHz
Square Frequency Range10 mHz to 16 MHz
Pulse Frequency Range1 mHz to 16 MHz
Triangle/Ramp Frequency Range10 mHz to 100 kHz
Noise Bandwidth8 MHz
Arbitrary Waveform Frequency Range10 mHz to 1.6 MHz
Frequency Resolution10 mHz or 7 digits
Frequency Accuracy±50 ppm

Pulse & Square Wave Characteristics

ParameterValue
Rise/Fall Time≤ 20 ns
Pulse Width Range30 ns to 999 s

Amplitude and Output Characteristics

ParameterValue
Amplitude Range (into 50 Ω)50 mVp-p to 10 Vp-p
Amplitude Range (into Open Circuit)100 mVp-p to 20 Vp-p
Amplitude Resolution3 digits
DC Offset Range (into 50 Ω)±5 V
DC Offset Range (into Open Circuit)±10 V
Output Impedance50 Ω

Modulation, Sweep, and Burst

ParameterValue
Modulation TypesAM, FM, FSK
AM Modulation Depth0% to 100%
FM Deviation Range10 mHz to 8 MHz (Sine, Square, Pulse); 10 mHz to 50 kHz (Triangle, Ramp)
FSK Rate (Internal)1 mHz to 50 kHz
Sweep TypeLinear, Logarithmic
Sweep Time Range1 ms to 500 s
Burst Count Range1 to 60,000 cycles
Burst TypeTriggered, Gated

Clock, Trigger, and Synchronization

ParameterValue
External Reference Input Frequency10 MHz
Trigger SourcesInternal, External, Manual

Software & Connectivity

ParameterValue
Direct Waveform LoadingLoad waveforms directly from selected Tektronix digital oscilloscopes via GPIB

Performance

ParameterValue
Sine Flatness±0.15 dB (up to 100 kHz), ±0.2 dB (100 kHz to 1 MHz), ±0.5 dB (1 MHz to 16 MHz)
Harmonic Distortion<-65 dBc (DC to 20 kHz), <-60 dBc (20 kHz to 100 kHz), <-45 dBc (100 kHz to 1 MHz), <-35 dBc (1 MHz to 16 MHz)
Total Harmonic Distortion<0.05% (20 Hz to 20 kHz, 1 Vp-p)
Spurious Distortion<-65 dBc (DC to 1 MHz), <-55 dBc (1 MHz to 16 MHz)
Phase Noise<-110 dBc/Hz at 10 kHz offset (10 MHz output)

Inputs & Outputs

ParameterValue
Sync Output LevelTTL compatible into >50 Ω
External Trigger Input Impedance10 kΩ
External Trigger Maximum Input Voltage±10 V
External Trigger Minimum Pulse Width100 ns
External AM Modulation Input Impedance10 kΩ
External AM Modulation Input Level±5 V for 100% modulation
Reference Clock Input Impedance1 kΩ
Reference Clock Input Level Range1 Vp-p to 10 Vp-p
Reference Clock Output Level1 Vp-p into 50 Ω
Reference Clock Output Impedance50 Ω

Environmental

ParameterValue
Storage Temperature Range-20 °C to +60 °C
Operating AltitudeUp to 3,000 m
Non-Operating AltitudeUp to 15,000 m

Compliance

ParameterValue
Safety StandardsUL3111-1, CAN/CSA-C22.2 No. 1010.1, EN 61010-1

Technology

Direct Digital Synthesis (DDS)

Applications

Electronic Test and Measurement

Looking for the Tektronix AFG310?

Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.

Selling this kind of equipment? Sell with us