The Tektronix CT-2 is a high-frequency AC current transformer designed for use with oscilloscopes and other 50 Ω terminated measuring instruments. It provides non-intrusive current measurements of circuit board traces and component leads by passing the conductor through its integrated aperture.

Specifications

General

ParameterValue
InterfacesSMA output connector

Physical

ParameterValue
Power SupplyPassive (no external power required)
Operating Temperature-15 to +55 °C
Dimensions (W×H×D)9.7 mm × 16.0 mm × 15.2 mm
Weight0.004 kg

Electrical Specifications

ParameterValue
Bandwidth (-3 dB)1.2 kHz to 200 MHz
Low-Frequency Cutoff (-3 dB)1.2 kHz
High-Frequency Cutoff (-3 dB)200 MHz
Sensitivity (Transfer Impedance)1 mV/mA (into 50 Ω)
Sensitivity Accuracy±3%
Rise Time1.7 ns
Decay Time Constant135 µs
Droop Rate0.7 %/µs
Amp-Second Product50 A-µs (50 µAs)
Maximum Continuous Current (RMS)2.5 A
Maximum Peak Pulse Current100 A
DC Current Limit (Saturation)0.5 A
Primary Insertion Impedance0.1 Ω at 10 MHz, 0.5 Ω at 100 MHz, 1.0 Ω at 200 MHz
Insertion Inductance5 nH

Physical and Mechanical Characteristics

ParameterValue
Aperture Diameter3.2 mm (0.125 in)
Output Connector TypeSMA

Compatibility and Accessories

ParameterValue
Required Termination Impedance50 Ω
Recommended Interconnecting CableP6041 (SMA to BNC)

Performance

ParameterValue
Propagation Delay2.3 ns

Electrical

ParameterValue
Maximum Bare-Wire Voltage30 V RMS

Environmental

ParameterValue
Storage Temperature-62 to +85 °C
Operating AltitudeUp to 4,570 m (15,000 ft)
Storage AltitudeUp to 15,240 m (50,000 ft)

Technology

Passive Current Transformer

Applications

High-frequency AC current measurements