The Tektronix P5205A is a 100 MHz high-voltage active differential probe designed for safe measurements on high-voltage circuits. It converts high-voltage differential floating signals to low-voltage signals referenced to ground, suitable for display on any oscilloscope. Featuring the TekProbe BNC interface, it seamlessly integrates with compatible Tektronix oscilloscopes to automatically scale measurements.

Specifications

General

ParameterValue
InterfacesTekProbe BNC
Standard Accessories2 hook clips (AC280-FL), 2 pincer clips (AC283-FL), 2 alligator clips (AC285-FL), 2 extension cables (196-3523-00)

Physical

ParameterValue
Power SupplyPowered directly by oscilloscopes with the TekProbe interface, or via the 1103 power supply
Operating Temperature0 to +50
Weight< 0.185 kg
Probe Head Dimensions111 mm x 22 mm x 14 mm
Compensation Box Dimensions107 mm x 40 mm x 26 mm

Electrical Performance

ParameterValue
Bandwidth (-3 dB)100 MHz
Rise Time (10% to 90%)<3.5 ns
Attenuation Ratios50X, 500X
DC Attenuation Accuracy±2%
Maximum Differential Voltage (500X)±1300 V (DC + pk AC)
Maximum Differential Voltage (50X)±130 V (DC + pk AC)
Maximum Common Mode Voltage±1300 V (DC + pk AC), 1000 V RMS CAT II
Maximum Input Voltage-to-Earth1000 V RMS CAT II
Input Resistance (Between Inputs)10 MΩ
Input Resistance (Each Input to Ground)5 MΩ
Input Capacitance (Between Inputs)4 pF
Input Capacitance (Each Input to Ground)8 pF
Propagation Delay17 ns (typical)
Overrange IndicatorAudible beep and visual LED

Common Mode Rejection Ratio (CMRR)

ParameterValue
CMRR at 60 Hz>80 dB
CMRR at 100 kHz>50 dB
CMRR at 1 MHz>30 dB

Output and Interface Specifications

ParameterValue
Interface TypeTekProbe BNC
Output Termination Impedance50 Ω (scope input must be set to 50 Ω)

Environmental Specifications

ParameterValue
Non-Operating Temperature Range-40 °C to +75 °C
Operating Humidity RangeUp to 90% RH at +30 °C (non-condensing)
Operating AltitudeUp to 3,000 m (10,000 ft)
Non-Operating AltitudeUp to 15,240 m (50,000 ft)

Safety and Compliance

ParameterValue
Safety Standards CertificationUL61010-1, CAN/CSA-C22.2 No. 61010-1, EN 61010-1, IEC 61010-1
Pollution Degree Rating2

Physical Characteristics

ParameterValue
Cable Length1.3 m

Performance

ParameterValue
System Noise (Referred to Input)<10 mVrms (50X attenuation), <80 mVrms (500X attenuation)

User Interface

ParameterValue
Controls and IndicatorsAttenuation selection button (50X/500X), Overrange LED indicator, Attenuation status LEDs

Technology

Active Differential

Applications

Power conversion, motor drive design, electronic ballast testing, UPS systems, and power supply design