The Tektronix P5210 is a high-voltage active differential probe capable of measuring floating voltages up to 5.6 kV (DC + pk AC) with a bandwidth of 50 MHz. It is designed for use with Tektronix oscilloscopes featuring the TekProbe interface, which provides power and automatic scale factor attenuation communication directly to the instrument.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | TekProbe BNC |
Physical
| Parameter | Value |
|---|---|
| Power Supply | Powered directly via TekProbe interface from oscilloscope, or through optional 1103 external power supply |
| Operating Temperature | 0 °C to +50 °C |
| Dimensions (W×H×D) | 207 mm × 83 mm × 38 mm |
| Weight | 0.47 kg |
Electrical Performance
| Parameter | Value |
|---|---|
| Bandwidth | 50 MHz |
| Rise Time | < 7 ns |
| Attenuation Ratio Options | 100x / 1000x |
| DC Attenuation Accuracy | ±3% |
| Differential Mode Voltage Range (100x) | ±560 V (DC + peak AC) |
| Differential Mode Voltage Range (1000x) | ±5.6 kV (DC + peak AC) |
| Maximum Common Mode Voltage Range | 2300 Vrms (CAT I), 1000 Vrms (CAT II) |
| Maximum Non-Destructive Input Voltage (Each Input to Earth) | 5.6 kV (DC + peak AC) CAT I, 2300 Vrms CAT I, 1000 Vrms CAT II, 600 Vrms CAT III |
| Input Resistance (Between Inputs) | 40 MΩ |
| Input Resistance (Each Input to Earth) | 20 MΩ |
| Input Capacitance (Between Inputs) | 2 pF |
| Input Capacitance (Each Input to Earth) | 4 pF |
| Common Mode Rejection Ratio (CMRR) at 60 Hz | 80 dB |
| Common Mode Rejection Ratio (CMRR) at 100 kHz | 50 dB |
| Common Mode Rejection Ratio (CMRR) at 1 MHz | 30 dB |
Connectivity & Interface
| Parameter | Value |
|---|---|
| Output Connector Type | TekProbe BNC |
Environmental Specifications
| Parameter | Value |
|---|---|
| Non-Operating Storage Temperature Range | -40 °C to +75 °C |
| Operating Humidity Range | Up to 90% RH (at or below +40 °C) |
| Storage Humidity Range | Up to 90% RH (at or below +40 °C) |
| Operating Altitude Limit | 3,000 m (10,000 ft) |
| Non-Operating Altitude Limit | 15,240 m (50,000 ft) |
Compliance & Safety Standards
| Parameter | Value |
|---|---|
| Pollution Degree Rating | 2 |
| Safety Standards Certifications | UL3111-1, EN61010-1, IEC61010-2-031 |
Physical Characteristics
| Parameter | Value |
|---|---|
| Input Lead Length | 30 cm |
| Output Cable Length | 1.8 m |
Performance
| Parameter | Value |
|---|---|
| Output Noise (100x) | < 4 mV RMS (into 1 MΩ load) |
| Output Noise (1000x) | < 3 mV RMS (into 1 MΩ load) |
| Propagation Delay | 18 ns (typical) |
| Input Coupling | DC |
| Bandwidth Limit Filter | Selectable 5 MHz / Full (50 MHz) |
| Output Impedance | 50 Ω (designed to drive 1 MΩ inputs) |
| Common Mode Rejection Ratio (CMRR) at DC | >80 dB |
Functional Features
| Parameter | Value |
|---|---|
| Overrange Indicator | Audible alarm and red LED |
| Power Indicator | Green LED |
Environmental
| Parameter | Value |
|---|---|
| Operating Vibration | 0.31 g RMS (5 Hz to 500 Hz) |
| Non-Operating Vibration | 2.46 g RMS (5 Hz to 500 Hz) |
| Non-Operating Mechanical Shock | 50 g (11 ms, half-sine) |
Technology
Active Differential
Applications
High-voltage floating measurements, power semiconductor characterization, motor drive design, power supply design, and power converter testing