The Tektronix P7330 is a high-performance 3.5 GHz active differential probe designed for use with oscilloscopes featuring the TekConnect interface. It provides high-bandwidth, low-loading differential measurements with excellent common-mode rejection, making it ideal for high-speed digital system design, debugging, and characterization.

Specifications

General

ParameterValue
InterfacesTekConnect

Physical

ParameterValue
Power SupplyPowered directly by host oscilloscope via TekConnect interface
Operating Temperature0 to +40

Electrical Performance Specifications

ParameterValue
Bandwidth3.5 GHz
Rise Time (10% to 90%)< 140 ps
Attenuation Ratio5:1
DC Attenuation Accuracy±1%
Differential Input Resistance100 kΩ
Single-Ended Input Resistance50 kΩ
Differential Input Capacitance< 0.3 pF (without tip accessories)
Differential Dynamic Range±2.0 V
Common Mode Operating Range±5.0 V
Maximum Non-Destructive Input Voltage±15 V (DC + peak AC)
Offset Range±1.25 V
System Noise (Referenced to Input)< 3.0 mV RMS

Frequency Response & Rejection

ParameterValue
Common Mode Rejection Ratio (CMRR) at 1 MHz> 60 dB
Common Mode Rejection Ratio (CMRR) at 100 MHz> 45 dB
Common Mode Rejection Ratio (CMRR) at 500 MHz> 40 dB
Common Mode Rejection Ratio (CMRR) at 1 GHz> 35 dB
Common Mode Rejection Ratio (CMRR) at 2 GHz> 30 dB

Connectivity & Interface

ParameterValue
Host Interface TypeTekConnect
Probe Cable Length1.3 m

Environmental Specifications

ParameterValue
Non-Operating Temperature Range-55 °C to +75 °C
Operating Humidity0% to 90% RH up to +30 °C, 0% to 75% RH above +30 °C to +40 °C
Operating AltitudeUp to 3,000 m
Non-Operating AltitudeUp to 15,240 m

Electrical Characteristics

ParameterValue
Rise Time (20% to 80%)< 90 ps (typical)
Propagation Delay5.3 ns
Output Impedance50 Ω

Reliability & Environmental

ParameterValue
ESD Tolerance> 8 kV

Compliance

ParameterValue
Safety CertificationsUL3111-1, CAN/CSA C22.2 No. 1010.1, EN 61010-1

Performance

ParameterValue
Single-Ended Input Capacitance< 0.5 pF
Common Mode Rejection Ratio (CMRR) at 3 GHz> 25 dB (typical)
Input CouplingDC

Technology

Active Differential

Applications

High-speed digital system design, differential signaling measurement, and debugging