The Tektronix P7360A is a high-performance 6.0 GHz Z-Active differential oscilloscope probe designed for use with TekConnect-enabled oscilloscopes. Employing Z-Active probe architecture, the P7360A provides high DC input resistance alongside exceptionally low high-frequency loading (capacitance < 0.3 pF), making it an outstanding tool for demanding high-speed digital design, differential signaling, and debug applications.

Specifications

General

ParameterValue
InterfacesTekConnect Interface
ESD Tolerance (Human Body Model)8 kV (typical)

Physical

ParameterValue
Power SupplyPowered directly by host oscilloscope via TekConnect interface
Operating Temperature0 °C to +40 °C
Weight0.124 kg

Electrical Performance Specifications

ParameterValue
Bandwidth6.0 GHz
Rise Time (10% to 90%)< 70 ps (typical)
Rise Time (20% to 80%)< 50 ps (typical)
Attenuation Ratios5X, 25X (user selectable)
DC Gain Accuracy±2%
Differential Input Resistance100 kΩ
Common Mode Input Resistance50 kΩ
Differential Input Capacitance< 0.3 pF (dependent on Z-Active tip cartridge used)

Voltage Range and Signal Limits

ParameterValue
Differential Dynamic Range (5X)2.0 V p-p (±1.0 V)
Differential Dynamic Range (25X)10.0 V p-p (±5.0 V)
Common Mode Operating Range+5.0 V to -4.0 V
Maximum Non-Destructive Input Voltage±15 V (DC + Peak AC)

Common Mode Rejection Ratio (CMRR)

ParameterValue
CMRR at DC> 60 dB (typical)
CMRR at 1 MHz> 55 dB (typical)
CMRR at 100 MHz> 40 dB (typical)
CMRR at 1 GHz> 30 dB (typical)
CMRR at 6 GHz> 20 dB (typical)

Connectivity and Interfaces

ParameterValue
Output Connection Interface TypeTekConnect Interface
Cable Length1.3 m (50 in)
Auto-Scaling SupportYes, automatic range and unit scaling supported on TekConnect hosts
Power RequirementsHost-supplied via TekConnect

Environmental and Safety Compliance

ParameterValue
Non-Operating Temperature Range-55 °C to +75 °C
Operating Humidity Range0% to 90% RH up to +30 °C, 0% to 75% RH up to +40 °C (non-condensing)
Operating AltitudeUp to 3,000 m (10,000 ft)
Storage AltitudeUp to 15,240 m (50,000 ft)

Standard and Optional Accessories

ParameterValue
Tip System CompatibilityTektronix P7380A series Z-Active tip cartridges (including Solder-in, Y-Lead, SMA, and Hand-held)

Performance

ParameterValue
Offset Range (5X)±2.5 V
Offset Range (25X)±12.5 V
Input Noise (5X)< 4 mV RMS
Input Noise (25X)< 20 mV RMS
Propagation Delay5.3 ns
Delay Jitter< 1 ps RMS (typical)

Compliance

ParameterValue
Safety ComplianceUL61010-1, CAN/CSA-C22.2 No. 61010-1, EN 61010-1, IEC 61010-1

Outputs

ParameterValue
Output Impedance50 Ω

Environmental

ParameterValue
Pollution DegreePollution Degree 2 (indoor use only)

Technology

Z-Active differential active probe

Applications

High-speed digital design, differential bus measurements, serial bus debugging