The Tektronix P7360A is a high-performance 6.0 GHz Z-Active differential oscilloscope probe designed for use with TekConnect-enabled oscilloscopes. Employing Z-Active probe architecture, the P7360A provides high DC input resistance alongside exceptionally low high-frequency loading (capacitance < 0.3 pF), making it an outstanding tool for demanding high-speed digital design, differential signaling, and debug applications.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | TekConnect Interface |
| ESD Tolerance (Human Body Model) | 8 kV (typical) |
Physical
| Parameter | Value |
|---|---|
| Power Supply | Powered directly by host oscilloscope via TekConnect interface |
| Operating Temperature | 0 °C to +40 °C |
| Weight | 0.124 kg |
Electrical Performance Specifications
| Parameter | Value |
|---|---|
| Bandwidth | 6.0 GHz |
| Rise Time (10% to 90%) | < 70 ps (typical) |
| Rise Time (20% to 80%) | < 50 ps (typical) |
| Attenuation Ratios | 5X, 25X (user selectable) |
| DC Gain Accuracy | ±2% |
| Differential Input Resistance | 100 kΩ |
| Common Mode Input Resistance | 50 kΩ |
| Differential Input Capacitance | < 0.3 pF (dependent on Z-Active tip cartridge used) |
Voltage Range and Signal Limits
| Parameter | Value |
|---|---|
| Differential Dynamic Range (5X) | 2.0 V p-p (±1.0 V) |
| Differential Dynamic Range (25X) | 10.0 V p-p (±5.0 V) |
| Common Mode Operating Range | +5.0 V to -4.0 V |
| Maximum Non-Destructive Input Voltage | ±15 V (DC + Peak AC) |
Common Mode Rejection Ratio (CMRR)
| Parameter | Value |
|---|---|
| CMRR at DC | > 60 dB (typical) |
| CMRR at 1 MHz | > 55 dB (typical) |
| CMRR at 100 MHz | > 40 dB (typical) |
| CMRR at 1 GHz | > 30 dB (typical) |
| CMRR at 6 GHz | > 20 dB (typical) |
Connectivity and Interfaces
| Parameter | Value |
|---|---|
| Output Connection Interface Type | TekConnect Interface |
| Cable Length | 1.3 m (50 in) |
| Auto-Scaling Support | Yes, automatic range and unit scaling supported on TekConnect hosts |
| Power Requirements | Host-supplied via TekConnect |
Environmental and Safety Compliance
| Parameter | Value |
|---|---|
| Non-Operating Temperature Range | -55 °C to +75 °C |
| Operating Humidity Range | 0% to 90% RH up to +30 °C, 0% to 75% RH up to +40 °C (non-condensing) |
| Operating Altitude | Up to 3,000 m (10,000 ft) |
| Storage Altitude | Up to 15,240 m (50,000 ft) |
Standard and Optional Accessories
| Parameter | Value |
|---|---|
| Tip System Compatibility | Tektronix P7380A series Z-Active tip cartridges (including Solder-in, Y-Lead, SMA, and Hand-held) |
Performance
| Parameter | Value |
|---|---|
| Offset Range (5X) | ±2.5 V |
| Offset Range (25X) | ±12.5 V |
| Input Noise (5X) | < 4 mV RMS |
| Input Noise (25X) | < 20 mV RMS |
| Propagation Delay | 5.3 ns |
| Delay Jitter | < 1 ps RMS (typical) |
Compliance
| Parameter | Value |
|---|---|
| Safety Compliance | UL61010-1, CAN/CSA-C22.2 No. 61010-1, EN 61010-1, IEC 61010-1 |
Outputs
| Parameter | Value |
|---|---|
| Output Impedance | 50 Ω |
Environmental
| Parameter | Value |
|---|---|
| Pollution Degree | Pollution Degree 2 (indoor use only) |
Technology
Z-Active differential active probe
Applications
High-speed digital design, differential bus measurements, serial bus debugging
Looking for the Tektronix P7360A?
Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.
Selling this kind of equipment? Sell with us