The Tektronix P7513A is a high-performance 13 GHz TriMode differential oscilloscope probe designed for use with TekConnect host oscilloscopes. Featuring TriMode technology, it allows users to perform differential, single-ended, and common-mode measurements through a single connection point, improving efficiency and signal fidelity in high-speed digital design and debugging applications.

Specifications

General

ParameterValue
InterfacesTekConnect
Warranty1 year

Physical

ParameterValue
Power SupplyPowered via TekConnect host interface
Operating Temperature0 °C to 40 °C
Weight0.153 kg

Electrical & Performance Specifications

ParameterValue
Analog Bandwidth13 GHz
Rise Time (10% to 90%)< 40 ps (typical)
Rise Time (20% to 80%)< 28 ps (typical)
Attenuation Settings5x, 12.5x
DC Input Resistance (Differential)100 kΩ
DC Input Resistance (Single-Ended)50 kΩ
Input Dynamic Range (Differential, 5x setting)0.75 V p-p (±0.375 V)
Input Dynamic Range (Differential, 12.5x setting)1.75 V p-p (±0.875 V)
Operating Voltage Window (Common Mode Range)+2.5 V to -1.5 V
Offset Range+2.5 V to -1.5 V
Maximum Non-Destructive Input Voltage±15 V (DC + peak AC)
Common Mode Rejection Ratio (CMRR) at DC> 60 dB
Common Mode Rejection Ratio (CMRR) at 1 GHz> 30 dB (typical)
System Noise (Referred to Input, 5x setting)< 1.1 mV RMS
System Noise (Referred to Input, 12.5x setting)< 2.5 mV RMS

Measurement Modes

ParameterValue
Differential ModeA minus B (TriMode setting)
Single-Ended Mode AA minus Ground (TriMode setting)
Single-Ended Mode BB minus Ground (TriMode setting)
Common ModeAverage of A and B (TriMode setting)

Connectivity & Host Interface

ParameterValue
Oscilloscope Interface TypeTekConnect
Cable Length1.2 m

Environmental Specifications

ParameterValue
Non-Operating Temperature Range-50 °C to 105 °C
Operating Humidity Range0% to 90% RH (at or below 30 °C); 0% to 75% RH (above 30 °C to 40 °C)
Operating Altitude3,000 m (9,843 feet)
Non-Operating Altitude12,000 m (39,370 feet)

Compliance & Calibration

ParameterValue
Recommended Calibration Interval1 year

Performance

ParameterValue
Propagation Delay5.6 ns ±0.1 ns
DC Attenuation Accuracy±2.0% (probe only), ±3.0% (system)
Output Impedance50 Ω

Features

ParameterValue
TriMode SettingsDifferential (A-B), Single-Ended A (A-GND), Single-Ended B (B-GND), Common-Mode ((A+B)/2 - GND)

User Interface

ParameterValue
Probe Control ButtonAllows switching between TriMode settings directly from the probe body

Compatibility

ParameterValue
Host Oscilloscope CompatibilityTekConnect oscilloscopes (DPO70000, DSA70000, MSO70000 series or equivalent with TekConnect interface)

Technology

TriMode Differential Probe

Applications

High-Speed Serial Bus Design, Signal Integrity, and Characterization