The Tektronix P7516 is a high-performance 16 GHz TriMode™ differential oscilloscope probe designed for use with Tektronix TekConnect® real-time oscilloscopes. It features the unique TriMode measurement capability, enabling differential, single-ended, and common-mode measurements through a single connection setup. Combined with the TekFlex™ connector system, it provides exceptional signal fidelity and minimal loading for high-speed serial bus analysis.

Specifications

General

ParameterValue
InterfacesTekConnect

Physical

ParameterValue
Power SupplyPowered directly by host oscilloscope through TekConnect interface
Operating Temperature0 °C to +40 °C

Electrical Performance

ParameterValue
Bandwidth16 GHz
Rise Time (10% to 90%)<= 32 ps
Rise Time (20% to 80%)<= 22 ps
Attenuation Settings5x, 12.5x
DC Input Resistance (Differential)100 kΩ
DC Input Resistance (Single-Ended)50 kΩ

Input Voltage & Dynamic Range

ParameterValue
Differential Dynamic Range (5x setting)0.75 Vp-p
Differential Dynamic Range (12.5x setting)2.0 Vp-p
Common Mode Operating Voltage Window+3.0 V to -2.0 V
DC Offset Range+2.5 V to -1.5 V
Maximum Non-Destructive Input Voltage (DC + Peak AC)±15 V

Signal Fidelity & Rejection

ParameterValue
Common Mode Rejection Ratio (CMRR) at DC> 60 dB
Common Mode Rejection Ratio (CMRR) at 50 MHz> 45 dB
Common Mode Rejection Ratio (CMRR) at 1 GHz> 30 dB
Common Mode Rejection Ratio (CMRR) at 10 GHz> 18 dB
Common Mode Rejection Ratio (CMRR) at 16 GHz> 15 dB

Measurement Modes & Control

ParameterValue
Measurement ModesTriMode™ (Differential (A-B), Single-Ended A, Single-Ended B, Common Mode)
DSP SupportDSP filter support on compatible Tektronix oscilloscopes for nominal channel flatness and phase response correction

Connectivity & Interface

ParameterValue
Host Interface TypeTekConnect®

Physical Characteristics

ParameterValue
Attached Cable Length1.0 m (3.3 feet)

Environmental Specifications

ParameterValue
Non-Operating Temperature Range-40 °C to +71 °C
Operating AltitudeUp to 3,000 m (9,843 feet)
Non-Operating AltitudeUp to 12,192 m (40,000 feet)

Electrical Characteristics

ParameterValue
DC Gain Accuracy (Differential)±2.0%
DC Gain Accuracy (Single-Ended)±2.0%
DC Gain Accuracy (Common Mode)±2.0%
DC Offset Accuracy±(1.5% of offset setting + 10 mV)
Input CouplingDC
Output Termination50 Ω
Propagation Delay (Typical)5.3 ns
Single-Ended Dynamic Range (12.5x setting)0.8 Vp-p
Common Mode Dynamic Range (5x setting)0.31 Vp-p
Common Mode Dynamic Range (12.5x setting)0.8 Vp-p

Environmental

ParameterValue
Operating Humidity5% to 95% RH at up to +30 °C, 5% to 85% RH above +30 °C up to +50 °C, non-condensing
Non-Operating Humidity5% to 95% RH at up to +30 °C, 5% to 85% RH above +30 °C up to +75 °C, non-condensing

Noise Characteristics

ParameterValue
Probe Noise (RTI, 5x setting)< 1.4 mV_rms (typical)
Probe Noise (RTI, 12.5x setting)< 3.0 mV_rms (typical)

System Performance

ParameterValue
System Bandwidth (with DPO/MSO71604)16 GHz

Technology

Active Differential TriMode

Applications

High-speed serial bus design, debugging, and characterization (PCI Express, Serial ATA, DDR, HDMI, DisplayPort)