The Tektronix TCP312 is a high-performance AC/DC current probe designed for use with the TCPA300 amplifier. Offering a wide bandwidth from DC to 100 MHz and a maximum continuous current measurement capability of 30 A, it is well-suited for high-frequency measurements in power electronics, automotive systems, and semiconductor development.

Specifications

General

ParameterValue
InterfacesProprietary probe interface (connects to TCPA300)
Probe TypeAC/DC Current Probe
Sensor TypeSplit-core Hall-effect and Transformer

Physical

ParameterValue
Power SupplyPowered via the TCPA300 amplifier
Operating Temperature0 °C to +50 °C
Dimensions (W×H×D)16 mm × 32 mm × 200 mm (Probe Head)

Electrical & Performance

ParameterValue
BandwidthDC to 100 MHz
Rise Time≤ 3.5 ns
Maximum Continuous DC Current30 A
Maximum RMS Current30 A
Maximum Peak Pulse Current50 A
Minimum Sensitivity1 mA (on oscilloscope with TCPA300)
DC Accuracy±3% of reading (with TCPA300)
Maximum Amp-Second Product11.2 A*µs
Insertion Impedance at 1 MHz0.08 Ω
Insertion Impedance at 10 MHz0.15 Ω
Insertion Impedance at 50 MHz0.27 Ω
Insertion Impedance at 100 MHz0.7 Ω
RMS Noise≤ 250 µA
Propagation Delay17 ns

Voltage & Safety Ratings

ParameterValue
Maximum Bare Wire Voltage150 V CAT II
Maximum Insulated Wire Voltage300 V CAT II
Pollution Degree2

System Compatibility & Interface

ParameterValue
Compatible AmplifierTCPA300

Physical & Mechanical

ParameterValue
Maximum Conductor Diameter5.0 mm (0.2 inches)
Cable Length1.5 m (5 feet)
Probe Head Width1.6 cm (0.6 inches)
Probe Head Height3.2 cm (1.3 inches)
Probe Head Length20.0 cm (7.9 inches)

Environmental

ParameterValue
Non-Operating Temperature Range-40 °C to +75 °C
Operating Humidity5% to 95% RH (up to +30 °C), 5% to 85% RH (+30 °C to +50 °C)
Operating Vibration0.31 g RMS (5 Hz to 500 Hz)
Non-Operating Vibration2.46 g RMS (5 Hz to 500 Hz)

Electrical Characteristics

ParameterValue
Input CouplingAC, DC

Connectivity

ParameterValue
Interface ConnectorProprietary 12-pin (mates directly with TCPA300)

Compliance

ParameterValue
Safety StandardsUL61010-1, UL61010-2-032, CAN/CSA-C22.2 No. 61010-1, CAN/CSA-C22.2 No. 61010-2-032, EN 61010-1, EN 61010-2-032, IEC 61010-1, IEC 61010-2-032

Performance

ParameterValue
Temperature Coefficient (Output Drift)≤0.25 mA/°C

Technology

Split-core AC/DC current measurement

Applications

Oscilloscope current measurement