The Tektronix TDP0500 is a 500 MHz active differential probe designed for use with oscilloscopes featuring the TekVPI™ interface. It provides high-speed differential signal acquisition with low device loading, excellent common-mode rejection, and versatile connectivity for modern digital system design and debugging.

Specifications

General

ParameterValue
InterfacesTekVPI

Physical

ParameterValue
Power SupplyPowered directly by host oscilloscope via TekVPI interface
Operating Temperature0 °C to +40 °C
Dimensions (W×H×D)106.7 mm x 41.1 mm x 31.8 mm (compensation box)
Weight0.146

Electrical Performance Specifications

ParameterValue
Bandwidth500 MHz
Rise Time (10% to 90%)< 700 ps
Attenuation Ratios5x, 50x
DC Attenuation Accuracy±2%
Input Resistance (Differential Mode)1 MΩ
Input Resistance (Common Mode)500 kΩ
Input Capacitance (Differential Mode)< 1 pF
Input Capacitance (Common Mode)< 2 pF
System Noise (Referred to Input, 5x)< 2 mV RMS
System Noise (Referred to Input, 50x)< 15 mV RMS
Propagation Delay5.4 ns (typical)

Voltage Range and Signal Limits

ParameterValue
Differential Dynamic Range (5x)±4.25 V
Differential Dynamic Range (50x)±42 V
Common Mode Operating Range±42 V
Maximum Non-Destructive Input Voltage (DC + Peak AC)±42 V

Common Mode Rejection Ratio (CMRR)

ParameterValue
CMRR at 60 Hz≥ 80 dB
CMRR at 1 MHz≥ 50 dB
CMRR at 100 MHz≥ 30 dB
CMRR at 500 MHz≥ 26 dB

Connectivity and Interfaces

ParameterValue
Output Connection Interface TypeTekVPI
Auto-Scaling / Auto-ID SupportYes
Cable Length1.2 m

Environmental and Safety Compliance

ParameterValue
Non-Operating Temperature Range-40 °C to +71 °C
Operating Humidity Range5% to 95% RH (at or below +30 °C); 5% to 85% RH (+30 °C to +40 °C)
Operating AltitudeUp to 3,000 m
Non-Operating AltitudeUp to 15,240 m

Physical Characteristics

ParameterValue
Probe Head Dimensions (W x H x D)10.9 mm x 7.6 mm x 57.2 mm

Compliance

ParameterValue
Safety ComplianceUL61010-1, CAN/CSA-C22.2 No. 61010-1, EN61010-1, IEC61010-1

Performance

ParameterValue
Selectable Bandwidth LimitsFull (500 MHz), 1 MHz, 10 kHz, 100 Hz
DC Reject0.4 Hz, 4 Hz
Offset Range±42 V

Controls & Indicators

ParameterValue
Compensation Box ControlsMenu, Range, Bandwidth, and AutoZero buttons

Technology

Active Differential

Applications

High-speed digital system design, differential signaling analysis, power supply design, and spectral measurements

Looking for the Tektronix TDP0500?

Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.

Selling this kind of equipment? Sell with us