The Tektronix THDP0200 is a 200 MHz high-voltage active differential probe designed for safe, high-speed differential voltage measurements of up to 1500 V. Integrating the TekVPI interface, it connects directly to compatible Tektronix oscilloscopes, drawing power and enabling auto-scaling and communication directly with the host instrument.

Specifications

General

ParameterValue
InterfacesTekVPI

Physical

ParameterValue
Power SupplyPowered directly by host oscilloscope via TekVPI interface
Operating Temperature0 to +40 °C
Dimensions (W×H×D)207 mm x 38 mm x 30 mm (probe head); 111 mm x 41 mm x 81 mm (compensation box)
Weight0.36

Electrical Performance

ParameterValue
Bandwidth200 MHz
Rise Time (10% to 90%)< 1.8 ns
Attenuation Ratios50x, 500x
DC Attenuation Accuracy±2%
Input Resistance (Differential Mode)10 MΩ
Input Resistance (Common Mode)5 MΩ
Input Capacitance (Differential Mode)< 2 pF
Input Capacitance (Common Mode)< 4 pF

Voltage Range and Signal Limits

ParameterValue
Differential Dynamic Range (50x)±150 V
Differential Dynamic Range (500x)±1500 V
Common Mode Operating Range±1500 V
Maximum Non-Destructive Input Voltage1000 V CAT II, 600 V CAT III

Common Mode Rejection Ratio (CMRR)

ParameterValue
CMRR at DC> -80 dB
CMRR at 100 kHz> -60 dB
CMRR at 3.2 MHz> -30 dB
CMRR at 100 MHz> -26 dB

Connectivity and Interfaces

ParameterValue
Output Connection Interface TypeTekVPI
Cable Length1.5 m
Auto-Scaling SupportYes

Environmental and Safety Compliance

ParameterValue
Non-Operating Temperature Range-40 to +75 °C
Operating Humidity Range5% to 90% RH (below +30 °C), 5% to 60% RH (+30 °C to +40 °C)
Operating AltitudeUp to 3,000 m
Safety CertificationsUL61010-031, EN61010-031, IEC61010-031
RoHS ComplianceYes

Safety & Compliance

ParameterValue
Safety Voltage Rating (Differential)1500 V CAT II / 1000 V CAT III
Safety Voltage Rating (Common Mode to Earth)1000 V CAT II / 600 V CAT III

Performance

ParameterValue
Selectable Bandwidth Limit5 MHz
Propagation Delay6.5 ns (typical)
Noise (50x Attenuation, Full Bandwidth)< 220 mVrms (referred to input)
Noise (500x Attenuation, Full Bandwidth)< 1.1 Vrms (referred to input)
Noise (50x Attenuation, 5 MHz BW Limit)< 150 mVrms (referred to input)
Noise (500x Attenuation, 5 MHz BW Limit)< 500 mVrms (referred to input)

Features

ParameterValue
Overrange IndicatorYes (visual LED and audible alarm)

Inputs & Outputs

ParameterValue
Input CouplingDC

Technology

Active Differential

Applications

High Voltage Differential Probing, Power Supply Design, Motor Drive Design, Power Device Evaluation