The Voltech PM6000 is a high-performance, multi-phase precision power analyzer designed for definitive measurements of electrical power on devices that consume, convert, or generate power. Combining advanced digital signal processing with up to six fully floating measurement channels and an embedded Linux PC, it provides superb accuracy, bandwidth, and common-mode rejection for demanding power analysis applications.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | RS-232, USB, Ethernet, GPIB |
| Display | VGA color display with numeric and graphic modes |
Physical
| Parameter | Value |
|---|---|
| Operating Temperature | 5 to 40 °C |
Input Channels & Configuration
| Parameter | Value |
|---|---|
| Maximum Number of Channels | 6 |
| Channel Isolation | Fully floating wattmeter channels |
| Phase Configurations | 1-phase 2-wire, 1-phase 3-wire, 3-phase 3-wire, 3-phase 4-wire |
Measurement Performance & Accuracy
| Parameter | Value |
|---|---|
| Frequency Bandwidth | DC, 10 mHz to 10 MHz |
| Sampling Rate | 40 MSPS |
| Basic Accuracy | 0.02% |
Data Logging, Memory & Visualization
| Parameter | Value |
|---|---|
| Display Formats | Numeric and graphic (waveform, vector, trend, harmonics) |
Voltage Measurement
| Parameter | Value |
|---|---|
| Maximum Voltage Input | 1000 Vrms (2000 Vpk) continuous |
Current Measurement
| Parameter | Value |
|---|---|
| Internal Current Shunt Options | 1 A (low current) or 30 A (high current) dual-range cards |
Performance
| Parameter | Value |
|---|---|
| A/D Conversion Resolution | 16-bit on all channels |
Measurement Parameters
| Parameter | Value |
|---|---|
| Measured Parameters | V, A, W, VA, VAr, PF, Hz, THD, Harmonics, Inrush Current, Crest Factor, Phase, Wh, Ah |
Harmonic Analysis
| Parameter | Value |
|---|---|
| Maximum Harmonic Order | 99 |
Compliance & Standards
| Parameter | Value |
|---|---|
| Safety Rating | IEC 61010-1, CAT II 1000 V, CAT III 600 V |
| Applicable Standards | IEC 61000-3-2, IEC 61000-3-3, IEC 61000-3-11, IEC 61000-3-12, IEC 62301 |
Inputs & Signal Conditioning
| Parameter | Value |
|---|---|
| Voltage Input Impedance | 1 MΩ |
| Crest Factor Capability | Up to 20:1 |
Measurement Performance
| Parameter | Value |
|---|---|
| Phase Angle Accuracy | ±(0.005° + 0.01°/kHz) |
Process Interface
| Parameter | Value |
|---|---|
| Auxiliary Analog Inputs | 4 channels (±10 V) |
| Auxiliary Pulse Inputs | 2 channels (up to 1 MHz) |
Technology
Digital Signal Processing (DSP)
Applications
Electrical power measurement, harmonic analysis, and efficiency testing