The Xantrex XFR600-4 is a high-performance 2400-watt DC power supply offering precise 0 to 600 VDC output and up to 4 A of current in a compact 2U rackmount chassis. Known for its high reliability, analog and digital control options, and robust regulation characteristics, it is ideal for demanding research, industrial, and automated test applications.
Specifications
General
| Parameter | Value |
|---|---|
| Display | Dual 3.5-digit LED displays for voltage and current |
| Warranty | 5 Years |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 190-250 VAC, 47-63 Hz, single-phase or three-phase |
| Operating Temperature | 0 to 50 °C |
| Dimensions (W×H×D) | 482.6 mm × 88.9 mm × 514.4 mm |
| Weight | 15 kg |
Output Ratings
| Parameter | Value |
|---|---|
| Output Voltage Range | 0 to 600 VDC |
| Output Current Range | 0 to 4 A |
| Maximum Output Power | 2400 W |
| Remote Sense Compensation | Up to 5 V drop per line |
Regulation
| Parameter | Value |
|---|---|
| Voltage Line Regulation | 0.05% of Vmax + 2 mV |
| Voltage Load Regulation | 0.05% of Vmax + 5 mV |
| Current Line Regulation | 0.1% of maximum output current |
| Current Load Regulation | 0.1% of maximum output current |
Noise & Ripple
| Parameter | Value |
|---|---|
| Output Voltage Ripple (RMS) | 150 mV |
| Output Voltage Ripple (p-p) | 500 mV |
| Output Current Ripple (RMS) | 5 mA |
Performance
| Parameter | Value |
|---|---|
| Transient Response Time | <1 ms |
| Voltage Temperature Coefficient | 0.02% of maximum output voltage per °C |
| Current Temperature Coefficient | 0.03% of maximum output current per °C |
User Interface & Readback
| Parameter | Value |
|---|---|
| Voltmeter Accuracy | ±1% of max voltage + 1 count |
| Ammeter Accuracy | ±1% of max current + 1 count |
Programming & Control
| Parameter | Value |
|---|---|
| Analog Programming Scale (Voltage) | 0-5 VDC or 0-10 VDC |
| Analog Programming Scale (Current) | 0-5 VDC or 0-10 VDC |
Protection
| Parameter | Value |
|---|---|
| Overvoltage Protection (OVP) Range | 10 to 660 VDC |
AC Input
| Parameter | Value |
|---|---|
| Nominal Input Current (Single Phase) | 19 A RMS @ 200 VAC |
| Nominal Input Current (Three Phase) | 11 A RMS @ 200 VAC |
Physical & Mechanical
| Parameter | Value |
|---|---|
| Cooling Method | Internal fan forced air cooling, rear exhaust |
| Rackmount height | 2U (EIA standard) |
Environmental
| Parameter | Value |
|---|---|
| Storage Temperature Range | -40 to +85 °C |
| Operating Humidity | 0 - 90% RH (non-condensing) |
| Storage Humidity | 0 - 95% RH (non-condensing) |
| Operating Altitude | up to 2000 m (6562 ft) |
| Storage Altitude | up to 3000 m (10000 ft) |
Input Specifications
| Parameter | Value |
|---|---|
| AC Input Voltage Range | 190 - 250 VAC (single or three phase) |
| AC Input Frequency | 47 - 63 Hz |
Programming & Monitoring
| Parameter | Value |
|---|---|
| Analog Programming Linearity | 0.1% of maximum output |
| Remote Shutdown Input | TTL-compatible or contact closure |
Operating Modes
| Parameter | Value |
|---|---|
| Operational Modes | Constant Voltage (CV) / Constant Current (CC) |
Compliance
| Parameter | Value |
|---|---|
| Safety Certifications | CSA C22.2 No. 1010.1, UL 3111-1 |
| EMC/EMI Compliance | FCC Part 15 Class A, CE |
User Interface
| Parameter | Value |
|---|---|
| Front Panel Controls | 10-turn voltage and current potentiometers, OVP adjustment trimpot, standby switch, preview switch |
Protection & Isolation
| Parameter | Value |
|---|---|
| Maximum Output Floating Voltage | ±600 VDC |
Interfaces
| Parameter | Value |
|---|---|
| Optional Interfaces | GPIB (IEEE-488.2) / RS-232 (via M9C card), LXI / Ethernet (via M130 card) |
Technology
Switch-mode DC Power Supply
Applications
Test and Measurement, Automated Test Systems (ATE), Burn-in, OEM integration