The Yokogawa WT210 is a high-performance, single-phase digital power meter designed for measuring small currents and power in industrial, consumer electronics, and research environments. With a wide current range starting at 5 mA up to 20 A direct input, and 0.1% basic accuracy, it delivers precise power, voltage, current, and integration measurements from DC and 0.5 Hz to 100 kHz. Highly compact and rack-mountable, the WT210 supports optional harmonic measurements and versatile connectivity like GP-IB and RS-232, making it an industry-standard fallback for efficiency and standby power testing.

Specifications

General

ParameterValue
InterfacesGP-IB (optional) / RS-232 (optional)
Display4-screen 5-digit LED display

Physical

ParameterValue
Power Supply100 V AC to 240 V AC, 50/60 Hz, maximum 15 VA
Operating Temperature5 to 40 °C
Dimensions (W×H×D)213 mm × 88 mm × 379 mm
Weight3.0 kg

Input Specifications

ParameterValue
Number of Input Elements1
Input Terminal TypeSafety terminals
Voltage Ranges (Crest Factor 3)15 V, 30 V, 60 V, 150 V, 300 V, 600 V
Voltage Ranges (Crest Factor 6)7.5 V, 15 V, 30 V, 75 V, 150 V, 300 V
Current Ranges (Direct Input, CF 3)0.5 mA, 1 mA, 2 mA, 5 mA, 10 mA, 20 mA, 50 mA, 100 mA, 200 mA, 500 mA, 1 A, 2 A, 5 A, 10 A, 20 A
Current Ranges (Direct Input, CF 6)0.25 mA, 0.5 mA, 1 mA, 2.5 mA, 5 mA, 10 mA, 25 mA, 50 mA, 100 mA, 250 mA, 0.5 A, 1 A, 2.5 A, 5 A, 10 A
External Current Sensor Input Ranges (CF 3)2.5 V, 5 V, 10 V
External Current Sensor Input Ranges (CF 6)1.25 V, 2.5 V, 5 V
Input Impedance (Voltage Input)Approx. 2 MΩ, 13 pF in parallel
Input Impedance (Current Input, Low Ranges)Approx. 500 mΩ (for 0.5 mA to 500 mA ranges)
Input Impedance (Current Input, High Ranges)Approx. 6 mΩ (for 1 A to 20 A ranges)
Maximum Input Voltage1000 Vrms
Maximum Input Current26 Arms
Continuous Maximum Allowed Overload (Voltage)1000 Vrms
Continuous Maximum Allowed Overload (Current)26 Arms
Crest Factor Capability3 or 6 (selectable)
Measurement Frequency BandwidthDC, 0.5 Hz to 100 kHz
Line Filter Cutoff Frequency5.5 kHz

Measurement Parameters & Functions

ParameterValue
Measured ParametersU, I, P, S, Q, lambda, phi, f, Wh, Ah
Active Power Accuracy±(0.1% of reading + 0.1% of range)
Voltage Accuracy±(0.1% of reading + 0.1% of range)
Current Accuracy±(0.1% of reading + 0.1% of range)
Frequency Measurement Range0.5 Hz to 100 kHz
Frequency Measurement Accuracy±(0.1% of reading + 1 digit)
Sampling RateApprox. 51.2 kHz
A/D Converter Resolution16-bit
Influence of Temperature±0.03% of range/°C (voltage/current), ±0.05% of range/°C (active power)
Influence of Common Mode Voltage±0.01% of range or less (600 V at 50/60 Hz)
Influence of Power Factor±0.15% of apparent power (S) at PF = 0

Integration (Energy) Function

ParameterValue
Integration ModesStandard, Continuous, Real-Time
Integration Timer Range0000:00:00 to 10000:00:00
Integration Accuracy±(Power/Current Accuracy + 0.02% of reading)
Watt-Hour Integration Range0.0000 mWh to 999999 MWh
Ampere-Hour Integration Range0.0000 mAh to 999999 MAh
Integration Auto-rangingSupported

Harmonic Measurement

ParameterValue
Harmonic Order Range1st to 50th order (with optional /HRM)
FFT Window Points1024 points (with optional /HRM)
THD Calculation ModesTotal / Fundamental (with optional /HRM)

Interfaces & Outputs

ParameterValue
D/A Output Channels12 channels (with optional /DA12)
D/A Output Voltage Range±5 V Full Scale
D/A Output Resolution12-bit
Remote Control CapabilitySupported via GP-IB or RS-232

Display & User Interface

ParameterValue
Number of Displayed Digits5 digits per screen
Display Update Rate0.1 s, 0.2 s, 0.5 s, 1.0 s, 2.0 s, 5.0 s (selectable)
Simultaneous Parameter Display Limit4 parameters
Display Hold FunctionSupported
Key Lock FunctionSupported

Physical & Power Specifications

ParameterValue
Warm-up Time RequirementApprox. 30 minutes

Environmental & Compliance

ParameterValue
Operating Humidity Range20% to 80% RH (non-condensing)
Storage Temperature Range-25 °C to 60 °C
Storage Humidity Range20% to 80% RH (non-condensing)
Maximum Operating Altitude2000 m
Safety StandardsComplies with EN61010-1
EMC StandardsComplies with EN61326-1
Insulation Resistance50 MΩ or more (at 500 V DC between power supply and case)
Withstanding Voltage1500 V AC for 1 minute (between power supply and case)

Safety & Compliance

ParameterValue
Maximum Common Mode Voltage600 Vrms (CAT II), 300 Vrms (CAT III)

Measurement Functions

ParameterValue
VT Ratio Range0.001 to 9999.999
CT Ratio Range0.001 to 9999.999
SF (Scaling Factor) Range0.001 to 9999.999
Phase Angle Display Range180.0 Lag to 180.0 Lead
Phase Angle Resolution0.1°

Signal Processing

ParameterValue
Averaging TypeExponential average or moving average
Exponential Averaging Attenuation Constant2, 4, 8, 16, 32, 64
Moving Average Count8, 16, 32, 64
Frequency Filter Cutoff Frequency500 Hz

Power Supply

ParameterValue
Power ConsumptionApprox. 15 VA (without options), max. 40 VA (with options)

Measurement Specifications

ParameterValue
Integration Timer Accuracy±0.005%
Effective Input Range1% to 110% of measurement range (CF 3), 2% to 110% of measurement range (CF 6)

Interfaces

ParameterValue
GP-IB Interface OptionOption /C1 (IEEE-488.2 compliant)
RS-232-C Interface OptionOption /C2
RS-232-C Baud Rates1200, 2400, 4800, 9600 bps
GP-IB Address Range0 to 30

Measurement Options

ParameterValue
Harmonic Measurement OptionOption /HR5
D/A Output OptionOption /DA4 (4 channels)
Harmonic Fundamental Frequency Range40 Hz to 440 Hz (with Option /HR5)

Inputs

ParameterValue
External Current Sensor Input ImpedanceApprox. 1 MΩ

Display

ParameterValue
Display Type7-segment LED

Technology

Digital Sampling

Applications

Electrical Power Measurement