The Yokogawa WT210 is a high-performance, single-phase digital power meter designed for measuring small currents and power in industrial, consumer electronics, and research environments. With a wide current range starting at 5 mA up to 20 A direct input, and 0.1% basic accuracy, it delivers precise power, voltage, current, and integration measurements from DC and 0.5 Hz to 100 kHz. Highly compact and rack-mountable, the WT210 supports optional harmonic measurements and versatile connectivity like GP-IB and RS-232, making it an industry-standard fallback for efficiency and standby power testing.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GP-IB (optional) / RS-232 (optional) |
| Display | 4-screen 5-digit LED display |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 V AC to 240 V AC, 50/60 Hz, maximum 15 VA |
| Operating Temperature | 5 to 40 °C |
| Dimensions (W×H×D) | 213 mm × 88 mm × 379 mm |
| Weight | 3.0 kg |
Input Specifications
| Parameter | Value |
|---|---|
| Number of Input Elements | 1 |
| Input Terminal Type | Safety terminals |
| Voltage Ranges (Crest Factor 3) | 15 V, 30 V, 60 V, 150 V, 300 V, 600 V |
| Voltage Ranges (Crest Factor 6) | 7.5 V, 15 V, 30 V, 75 V, 150 V, 300 V |
| Current Ranges (Direct Input, CF 3) | 0.5 mA, 1 mA, 2 mA, 5 mA, 10 mA, 20 mA, 50 mA, 100 mA, 200 mA, 500 mA, 1 A, 2 A, 5 A, 10 A, 20 A |
| Current Ranges (Direct Input, CF 6) | 0.25 mA, 0.5 mA, 1 mA, 2.5 mA, 5 mA, 10 mA, 25 mA, 50 mA, 100 mA, 250 mA, 0.5 A, 1 A, 2.5 A, 5 A, 10 A |
| External Current Sensor Input Ranges (CF 3) | 2.5 V, 5 V, 10 V |
| External Current Sensor Input Ranges (CF 6) | 1.25 V, 2.5 V, 5 V |
| Input Impedance (Voltage Input) | Approx. 2 MΩ, 13 pF in parallel |
| Input Impedance (Current Input, Low Ranges) | Approx. 500 mΩ (for 0.5 mA to 500 mA ranges) |
| Input Impedance (Current Input, High Ranges) | Approx. 6 mΩ (for 1 A to 20 A ranges) |
| Maximum Input Voltage | 1000 Vrms |
| Maximum Input Current | 26 Arms |
| Continuous Maximum Allowed Overload (Voltage) | 1000 Vrms |
| Continuous Maximum Allowed Overload (Current) | 26 Arms |
| Crest Factor Capability | 3 or 6 (selectable) |
| Measurement Frequency Bandwidth | DC, 0.5 Hz to 100 kHz |
| Line Filter Cutoff Frequency | 5.5 kHz |
Measurement Parameters & Functions
| Parameter | Value |
|---|---|
| Measured Parameters | U, I, P, S, Q, lambda, phi, f, Wh, Ah |
| Active Power Accuracy | ±(0.1% of reading + 0.1% of range) |
| Voltage Accuracy | ±(0.1% of reading + 0.1% of range) |
| Current Accuracy | ±(0.1% of reading + 0.1% of range) |
| Frequency Measurement Range | 0.5 Hz to 100 kHz |
| Frequency Measurement Accuracy | ±(0.1% of reading + 1 digit) |
| Sampling Rate | Approx. 51.2 kHz |
| A/D Converter Resolution | 16-bit |
| Influence of Temperature | ±0.03% of range/°C (voltage/current), ±0.05% of range/°C (active power) |
| Influence of Common Mode Voltage | ±0.01% of range or less (600 V at 50/60 Hz) |
| Influence of Power Factor | ±0.15% of apparent power (S) at PF = 0 |
Integration (Energy) Function
| Parameter | Value |
|---|---|
| Integration Modes | Standard, Continuous, Real-Time |
| Integration Timer Range | 0000:00:00 to 10000:00:00 |
| Integration Accuracy | ±(Power/Current Accuracy + 0.02% of reading) |
| Watt-Hour Integration Range | 0.0000 mWh to 999999 MWh |
| Ampere-Hour Integration Range | 0.0000 mAh to 999999 MAh |
| Integration Auto-ranging | Supported |
Harmonic Measurement
| Parameter | Value |
|---|---|
| Harmonic Order Range | 1st to 50th order (with optional /HRM) |
| FFT Window Points | 1024 points (with optional /HRM) |
| THD Calculation Modes | Total / Fundamental (with optional /HRM) |
Interfaces & Outputs
| Parameter | Value |
|---|---|
| D/A Output Channels | 12 channels (with optional /DA12) |
| D/A Output Voltage Range | ±5 V Full Scale |
| D/A Output Resolution | 12-bit |
| Remote Control Capability | Supported via GP-IB or RS-232 |
Display & User Interface
| Parameter | Value |
|---|---|
| Number of Displayed Digits | 5 digits per screen |
| Display Update Rate | 0.1 s, 0.2 s, 0.5 s, 1.0 s, 2.0 s, 5.0 s (selectable) |
| Simultaneous Parameter Display Limit | 4 parameters |
| Display Hold Function | Supported |
| Key Lock Function | Supported |
Physical & Power Specifications
| Parameter | Value |
|---|---|
| Warm-up Time Requirement | Approx. 30 minutes |
Environmental & Compliance
| Parameter | Value |
|---|---|
| Operating Humidity Range | 20% to 80% RH (non-condensing) |
| Storage Temperature Range | -25 °C to 60 °C |
| Storage Humidity Range | 20% to 80% RH (non-condensing) |
| Maximum Operating Altitude | 2000 m |
| Safety Standards | Complies with EN61010-1 |
| EMC Standards | Complies with EN61326-1 |
| Insulation Resistance | 50 MΩ or more (at 500 V DC between power supply and case) |
| Withstanding Voltage | 1500 V AC for 1 minute (between power supply and case) |
Safety & Compliance
| Parameter | Value |
|---|---|
| Maximum Common Mode Voltage | 600 Vrms (CAT II), 300 Vrms (CAT III) |
Measurement Functions
| Parameter | Value |
|---|---|
| VT Ratio Range | 0.001 to 9999.999 |
| CT Ratio Range | 0.001 to 9999.999 |
| SF (Scaling Factor) Range | 0.001 to 9999.999 |
| Phase Angle Display Range | 180.0 Lag to 180.0 Lead |
| Phase Angle Resolution | 0.1° |
Signal Processing
| Parameter | Value |
|---|---|
| Averaging Type | Exponential average or moving average |
| Exponential Averaging Attenuation Constant | 2, 4, 8, 16, 32, 64 |
| Moving Average Count | 8, 16, 32, 64 |
| Frequency Filter Cutoff Frequency | 500 Hz |
Power Supply
| Parameter | Value |
|---|---|
| Power Consumption | Approx. 15 VA (without options), max. 40 VA (with options) |
Measurement Specifications
| Parameter | Value |
|---|---|
| Integration Timer Accuracy | ±0.005% |
| Effective Input Range | 1% to 110% of measurement range (CF 3), 2% to 110% of measurement range (CF 6) |
Interfaces
| Parameter | Value |
|---|---|
| GP-IB Interface Option | Option /C1 (IEEE-488.2 compliant) |
| RS-232-C Interface Option | Option /C2 |
| RS-232-C Baud Rates | 1200, 2400, 4800, 9600 bps |
| GP-IB Address Range | 0 to 30 |
Measurement Options
| Parameter | Value |
|---|---|
| Harmonic Measurement Option | Option /HR5 |
| D/A Output Option | Option /DA4 (4 channels) |
| Harmonic Fundamental Frequency Range | 40 Hz to 440 Hz (with Option /HR5) |
Inputs
| Parameter | Value |
|---|---|
| External Current Sensor Input Impedance | Approx. 1 MΩ |
Display
| Parameter | Value |
|---|---|
| Display Type | 7-segment LED |
Technology
Digital Sampling
Applications
Electrical Power Measurement