The Yokogawa WT230 is a compact, high-performance three-phase digital sampling power meter designed for high-accuracy power measurements from DC and 0.5 Hz up to 100 kHz. Featuring a basic accuracy of 0.1%, a large maximum direct current input of 26 A, and a high-speed data update rate of up to 10 readings per second, the WT230 offers outstanding cost performance in a half-rack form factor. It supports various options such as harmonic measurement, D/A outputs, and communication interfaces like GP-IB or RS-232, making it an ideal choice for testing home appliances, motors, and industrial equipment.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GP-IB (optional), RS-232 (optional) |
| Display | 4-window LED display |
| Recommended Calibration Cycle | 1 year |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 to 240 VAC, 50/60 Hz, max 40 VA |
| Operating Temperature | 5 to 40 °C |
| Dimensions (W×H×D) | 213 mm × 132 mm × 379 mm (W×H×D, excluding projections) |
| Weight | 5.0 kg (with 3-element configuration) |
Measurement Input
| Parameter | Value |
|---|---|
| Number of Input Elements | 2 or 3 elements (configuration dependent) |
| Wiring System Compatibility | 1P2W, 1P3W, 3P3W, 3P4W (configuration dependent) |
| Measurement Parameters | Voltage, Current, Active Power, Apparent Power, Reactive Power, Power Factor, Phase Angle, Frequency, Active Energy (Integration), Current Integration |
| Input Type | Floating input, shunt resistance for current |
Voltage Ranges
| Parameter | Value |
|---|---|
| Voltage Range Settings (RMS) | 15 V, 30 V, 60 V, 150 V, 300 V, 600 V |
| Voltage Crest Factor | 3 (at rated range input) |
| Voltage Input Impedance | Approx. 2 MΩ, 13 pF in parallel |
| Maximum Direct Input Voltage | 1000 Vrms |
Current Ranges
| Parameter | Value |
|---|---|
| Direct Current Range Settings (RMS) | 0.5 A, 1 A, 2 A, 5 A, 10 A, 20 A |
| Current Crest Factor | 3 (at rated range input) |
| Maximum Continuous Current Input | 26 Arms (assured accuracy) |
| External Current Sensor Input Ranges | 2.5 V, 5.0 V, 10.0 V |
Accuracy & Performance
| Parameter | Value |
|---|---|
| Frequency Range | DC, 0.5 Hz to 100 kHz |
| Basic Measurement Accuracy | ±(0.1% of reading + 0.1% of range) at 50/60 Hz |
| DC Measurement Accuracy | ±(0.2% of reading + 0.2% of range) |
| Frequency Measurement Accuracy | ±(0.1% of reading + 1 digit) |
| Effective Input Range | 1% to 110% of the measurement range |
Sampling & Processing
| Parameter | Value |
|---|---|
| A/D Converter Resolution | 16-bit |
| Sampling Rate | Approx. 51.2 kHz |
| Data Update Rate Selection | 0.1 s, 0.2 s, 0.5 s, 1 s, 2 s, 5 s |
Functions & Features
| Parameter | Value |
|---|---|
| Line Filter Cutoff Frequency | 5.5 kHz |
| Scaling Function Factor (PT/CT/SF) | 0.001 to 9999.999 |
| Averaging Selection | Exponential or Moving Average (attenuation constant 8, 16, 32, 64) |
| Peak Hold Function | Holds maximum value of Voltage and Current |
| Integration Modes | Standard, Continuous |
| Integration Time Range | 0000h 00m 00s to 10000h 00m 00s |
| Integration Timer Accuracy | ±0.005% of reading |
| Harmonic Measurement Option (/G5) | Up to 50th harmonic order, basic frequency 40 Hz to 440 Hz |
| D/A Output Option (/DA12) | 12 channels, ±5 V full scale output |
User Interface
| Parameter | Value |
|---|---|
| Display Resolution | 99999 counts |
General Specifications
| Parameter | Value |
|---|---|
| Storage Temperature Range | -25 °C to 60 °C |
| Operating Humidity Range | 20% to 80% RH (no condensation) |
| Storage Humidity Range | 20% to 80% RH (no condensation) |
| Maximum Operating Altitude | 2000 m |
| Insulation Resistance | 50 MΩ or more at 500 VDC |
| Withstand Voltage | 1500 Vrms for 1 minute (between power supply and casing) |
| Safety Standards Compliance | EN61010-1, EN61010-2-031 |
| EMC Standards Compliance | EN55011, EN50082-2 |
| Warm-Up Time | Approx. 30 minutes |
| Memory Type for Settings | Lithium battery backup (approx. 10 years lifetime at 23°C) |
Input Specifications
| Parameter | Value |
|---|---|
| Current Input Impedance | Approx. 6 mΩ + 0.11 µH (direct input) |
| External Current Sensor Input Impedance | Approx. 1 MΩ |
| Maximum Allowed Input Voltage | 1000 Vrms or 1500 Vpeak, whichever is less |
| Maximum Allowed Input Current | 30 Arms or 100 Apeak, whichever is less (for direct input) |
Accuracy/Influence
| Parameter | Value |
|---|---|
| Temperature Coefficient | Add ±0.03% of reading/°C (for 5°C to 18°C and 28°C to 40°C) |
| Influence of Power Factor | With PF = 0 (at active power): ±0.15% of S (apparent power) at 50/60 Hz |
| Influence of Common Mode Voltage | ±0.1% of range or less with 600 Vrms applied between input terminal and case (50/60 Hz) |
Measurement Functions
| Parameter | Value |
|---|---|
| Frequency Measurement Channels | 2 channels (selectable from voltage or current of any input element) |
| PT Ratio Range | 0.001 to 9999 |
| CT Ratio Range | 0.001 to 9999 |
| SF (Scaling Factor) Range | 0.001 to 9999 |
| Exponential Average Attenuation Constant | 2, 4, 8, 16, 32, 64 |
| Moving Average Number of Samples | 8, 16, 32, 64 |
D/A Output Option (/DA12)
| Parameter | Value |
|---|---|
| D/A Output Voltage | ±5 V FS (approx. ±7.5 V maximum) relative to each rated value |
| D/A Output Resolution | 12-bit |
| D/A Output Update Rate | Same as the main unit data update rate |
Harmonic Measurement Option (/G5)
| Parameter | Value |
|---|---|
| PLL Synchronization Frequency Range | 40 Hz to 440 Hz |
| Maximum Harmonic Analysis Order | 50th order |
Filters
| Parameter | Value |
|---|---|
| Frequency Filter Cutoff Frequency | 500 Hz |
Control & Interfaces
| Parameter | Value |
|---|---|
| External Control Signal Input Level | TTL (0 to 5 V) |
| External Control Inputs | EXT START, EXT STOP, EXT RESET, EXT HOLD, EXT SINGLE |
Options
| Parameter | Value |
|---|---|
| Ethernet Interface Standard (Option /C7) | IEEE 802.3 10BASE-T |
| Ethernet Protocol (Option /C7) | TCP/IP |
| GP-IB Interface Standards (Option /C1) | IEEE 488.1-1978, IEEE 488.2-1987 |
| Harmonic Measurement Fundamental Frequency (Option /G5) | 40 Hz to 440 Hz |
| D/A Output Channels (Option /DA12) | 12 channels |
| D/A Output Voltage Range (Option /DA12) | ±5 V FS (approx. ±7.5 V max) relative to each rated value |
| Comparator Output Channels (Option /DA12) | 4 channels (high/low limits for up to 2 parameters) |
| Comparator Output Type (Option /DA12) | Open collector (maximum 24 VDC, 50 mA) |
Looking for the Yokogawa WT230?
Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.
Selling this kind of equipment? Sell with us