The Yokogawa WT3000 is an industry-standard precision power analyzer designed to deliver ultra-high-accuracy power measurements. With a basic voltage/current reading accuracy of 0.01% and power reading accuracy of 0.02%, a broad measurement bandwidth of DC and 0.1 Hz to 1 MHz, and support for up to four input elements, the WT3000 provides high-precision evaluation of inverter efficiency, motor characteristics, and power semiconductor loss. Equipped with an 8.4-inch color LCD display and advanced mathematical calculation functions, it is widely utilized in R&D and calibration laboratories worldwide.

Specifications

General

ParameterValue
Display8.4-inch color TFT LCD, 640 × 480 (VGA)

Physical

ParameterValue
Power Supply100 to 240 VAC, 50/60 Hz, 150 VA max
Operating Temperature5 to 40 °C
Dimensions (W×H×D)426 × 177 × 459 mm
Weight15 kg

Input Specifications

ParameterValue
Number of Input ElementsUp to 4 elements (mix of 2 A and 30 A elements possible)
Input Element Configuration Types1P2W, 1P3W, 3P3W, 3P3W (3V3A), 3P4W
Voltage Direct Input Ranges (Crest Factor 3)15, 30, 60, 100, 150, 300, 600, 1000 V
Voltage Direct Input Ranges (Crest Factor 6)7.5, 15, 30, 50, 75, 150, 300, 500 V
Current Direct Input Ranges (2 A Element, Crest Factor 3)0.5, 1, 2, 5, 10, 20, 50, 100, 200, 500 mA, 1, 2 A
Current Direct Input Ranges (2 A Element, Crest Factor 6)0.25, 0.5, 1, 2.5, 5, 10, 25, 50, 100, 250 mA, 0.5, 1 A
Current Direct Input Ranges (30 A Element, Crest Factor 3)0.5, 1, 2, 5, 10, 20, 30 A
Current Direct Input Ranges (30 A Element, Crest Factor 6)0.25, 0.5, 1, 2.5, 5, 10, 15 A
External Current Sensor Input Ranges (Crest Factor 3)50, 100, 200, 500 mV, 1, 2, 5, 10 V
External Current Sensor Input Ranges (Crest Factor 6)25, 50, 100, 250 mV, 0.5, 1, 2.5, 5 V
Voltage Input ImpedanceApprox. 10 MOhm, approx. 5 pF
Current Input Impedance (2 A Element)Approx. 100 mOhm + 0.15 uH
Current Input Impedance (30 A Element)Approx. 5.5 mOhm + 0.15 uH
Maximum Input Voltage (Continuous)1000 Vrms or 1500 Vpeak, whichever is less
Maximum Continuous Input Current (2 A Element)3 Arms or 6 Apeak, whichever is less
Maximum Continuous Input Current (30 A Element)33 Arms or 150 Apeak, whichever is less
A/D Converter Resolution16-bit
Sampling RateApprox. 200 kS/s
External Current Sensor Input Impedance1 MΩ (approx. 100 pF)
Voltage Input Terminal TypeSafety terminal (female)
Current Input Terminal TypeSafety terminal (female)

Measurement Accuracy

ParameterValue
Basic Voltage Accuracy (AC, 50/60 Hz)±(0.01% of reading + 0.03% of range)
Basic Voltage Accuracy (DC)±(0.05% of reading + 0.05% of range)
Basic Current Accuracy (AC, 50/60 Hz)±(0.01% of reading + 0.03% of range)
Basic Current Accuracy (DC, 2 A Element)±(0.05% of reading + 0.05% of range)
Basic Current Accuracy (DC, 30 A Element)±(0.05% of reading + 0.1% of range)
Basic Active Power Accuracy (AC, 50/60 Hz)±(0.02% of reading + 0.04% of range)
Basic Active Power Accuracy (DC, 2 A Element)±(0.05% of reading + 0.05% of range)
Basic Active Power Accuracy (DC, 30 A Element)±(0.05% of reading + 0.1% of range)
Frequency BandwidthDC, 0.1 Hz to 1 MHz
Influence of Power Factor±0.03% of S (apparent power) when PF = 0 (at 50/60 Hz)
Influence of Common Mode Voltage±0.01% of range or less (1000 Vrms, 50/60 Hz)

Measurement Parameters & Calculation Functions

ParameterValue
Voltage/Current Crest FactorSelectable 3 or 6
Frequency Measurement Range0.15 Hz to 1 MHz
Integration Accuracy±(Power/Current Accuracy + 0.02% of reading)
Integration Auto-RangeSupported
Efficiency CalculationUp to 4 efficiency equations can be defined (eta1 to eta4)
User-Defined CalculationsUp to 20 equations (F1 to F20)

Harmonic Measurement Capabilities

ParameterValue
Harmonic Measurement Frequency RangeFundamental frequency from 10 Hz to 2.6 kHz (PLL synchronization)
Maximum Harmonic Order AnalysedUp to 100th order (fundamental frequency of 50/60 Hz)
Total Harmonic Distortion (THD) CalculationsIEC standard or CSA standard selectable
Dual Harmonic MeasurementSupported (with option /G6)

Motor Evaluation Function (Option)

ParameterValue
Motor Channels Supported1 channel
Torque Sensor Input TypeAnalog (DC voltage) or Pulse (frequency)
Speed Sensor Input TypeAnalog (DC voltage) or Pulse (frequency)
Mechanical Power (Pm) CalculationPm = Speed * Torque * Constant
Electrical Angle Measurement CapabilitySupported with option /MTR

Display & User Interface

ParameterValue
Display Type8.4-inch color TFT LCD
Display Resolution640 × 480 pixels (VGA)
Display Update Rate50 ms to 20 s (selectable)
Numeric Display Formats4, 8, 16, All items, Single list, Dual list
Waveform Display ModeSupported
Harmonic Bar Graph Display ModeSupported
Vector Display ModeSupported
Trend Display ModeSupported

Interfaces & Connectivity

ParameterValue
GP-IB InterfaceIEEE-488.2 compliant
Ethernet Port100BASE-TX/10BASE-T
RS-232/Serial Interface9-pin D-sub (male)
USB PC Link Port (Device)USB Type B (USB 1.1 compliant)
USB Storage Port (Host)USB Type A (USB 1.1 compliant)
D/A Output Channels (Option)20 channels (with option /DA)
External Trigger InputBNC terminal, TTL level
Video OutputVGA, 15-pin D-sub (female)

Power Supply & Physical Specifications

ParameterValue
Line Voltage Frequency50/60 Hz
Supply Voltage Range100 to 240 VAC
Power Consumption (Max)150 VA
Warm-up TimeApprox. 30 minutes

Environmental & Safety Standards

ParameterValue
Operating Temperature Range5 to 40 °C
Operating Humidity Range20% to 80% RH (no condensation)
Storage Temperature Range-25 to 60 °C
Safety Standard ComplianceEN61010-1
Measurement Category (CAT Rating)CAT II 1000V
EMC Directive ComplianceEN61326-1 Class A

Filters

ParameterValue
Line Filter Cutoff Frequencies500 Hz, 5.5 kHz, 50 kHz, 1 MHz
Frequency Filter Cutoff Frequencies100 Hz, 500 Hz, 2 kHz, 20 kHz

Storage & Interface Options

ParameterValue
Internal Data Storage CapacityApprox. 30 MB
PC Card SlotType II PC Card slot

Measurement Options

ParameterValue
Voltage Fluctuation & Flicker MeasurementCompliant with IEC61000-3-3 and IEC61000-4-15 (option /FL)
Delta Calculation FunctionsLine-to-line voltage, phase voltage, and neutral current calculations (option /DT)

Physical Options

ParameterValue
Built-in Printer SpecificationThermal line dot printer, 112 mm paper width (option /B5)

Environmental

ParameterValue
Operating AltitudeUp to 2000 m

Accuracy Specifications

ParameterValue
Voltage/Current Temperature CoefficientAdd ±0.01% of reading/°C (within 5 to 18 °C or 28 to 40 °C)
Active Power Temperature CoefficientAdd ±0.02% of reading/°C (within 5 to 18 °C or 28 to 40 °C)
Influence of Self-Heating (30 A Element Current)Add 0.004 × I² % of reading to current and active power accuracy (where I is the current in A)
Influence of Magnetic FieldAdd ±0.1% of range or less (at 400 A/m, 50/60 Hz)

Measurement

ParameterValue
Effective Measurement Range (Voltage/Current)1% to 110% of range (Crest Factor 3)
Effective Measurement Range (Power)1% to 121% of range (Crest Factor 3)
Integration Time Setting Range0 hours 00 minutes 00 seconds to 10000 hours 00 minutes 00 seconds
Data Update Rate Options50 ms, 100 ms, 250 ms, 500 ms, 1 s, 2 s, 5 s, 10 s, 20 s, and Auto

Harmonic Measurement

ParameterValue
Advanced Harmonic Measurement Maximum Order500th order (with Option /G6, fundamental frequency 50/60 Hz)

Motor Evaluation Option

ParameterValue
Speed Input Range (Analog)±1 V, ±2 V, ±5 V, ±10 V (with Option /MTR)
Torque Input Range (Analog)±1 V, ±2 V, ±5 V, ±10 V (with Option /MTR)
Speed/Torque Pulse Input Frequency Range2 Hz to 1 MHz (with Option /MTR)

D/A Output

ParameterValue
D/A Output Resolution16-bit (with Option /DA)
D/A Output Voltage Range±5 V FS (approx. ±7.5 V maximum)

Safety & General

ParameterValue
Insulation Resistance50 MΩ or more at 500 VDC (between input terminals and case, and between input elements)
Withstand Voltage5.55 kVAC for 1 minute (between input terminals and case)

Technology

Precision Power Analyzer

Applications

Inverter evaluation, high-efficiency motor testing, power semiconductor loss measurement, calibration, and power grid quality testing