The Yokogawa WT3000 is an industry-standard precision power analyzer designed to deliver ultra-high-accuracy power measurements. With a basic voltage/current reading accuracy of 0.01% and power reading accuracy of 0.02%, a broad measurement bandwidth of DC and 0.1 Hz to 1 MHz, and support for up to four input elements, the WT3000 provides high-precision evaluation of inverter efficiency, motor characteristics, and power semiconductor loss. Equipped with an 8.4-inch color LCD display and advanced mathematical calculation functions, it is widely utilized in R&D and calibration laboratories worldwide.
Specifications
General
| Parameter | Value |
|---|---|
| Display | 8.4-inch color TFT LCD, 640 × 480 (VGA) |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 100 to 240 VAC, 50/60 Hz, 150 VA max |
| Operating Temperature | 5 to 40 °C |
| Dimensions (W×H×D) | 426 × 177 × 459 mm |
| Weight | 15 kg |
Input Specifications
| Parameter | Value |
|---|---|
| Number of Input Elements | Up to 4 elements (mix of 2 A and 30 A elements possible) |
| Input Element Configuration Types | 1P2W, 1P3W, 3P3W, 3P3W (3V3A), 3P4W |
| Voltage Direct Input Ranges (Crest Factor 3) | 15, 30, 60, 100, 150, 300, 600, 1000 V |
| Voltage Direct Input Ranges (Crest Factor 6) | 7.5, 15, 30, 50, 75, 150, 300, 500 V |
| Current Direct Input Ranges (2 A Element, Crest Factor 3) | 0.5, 1, 2, 5, 10, 20, 50, 100, 200, 500 mA, 1, 2 A |
| Current Direct Input Ranges (2 A Element, Crest Factor 6) | 0.25, 0.5, 1, 2.5, 5, 10, 25, 50, 100, 250 mA, 0.5, 1 A |
| Current Direct Input Ranges (30 A Element, Crest Factor 3) | 0.5, 1, 2, 5, 10, 20, 30 A |
| Current Direct Input Ranges (30 A Element, Crest Factor 6) | 0.25, 0.5, 1, 2.5, 5, 10, 15 A |
| External Current Sensor Input Ranges (Crest Factor 3) | 50, 100, 200, 500 mV, 1, 2, 5, 10 V |
| External Current Sensor Input Ranges (Crest Factor 6) | 25, 50, 100, 250 mV, 0.5, 1, 2.5, 5 V |
| Voltage Input Impedance | Approx. 10 MOhm, approx. 5 pF |
| Current Input Impedance (2 A Element) | Approx. 100 mOhm + 0.15 uH |
| Current Input Impedance (30 A Element) | Approx. 5.5 mOhm + 0.15 uH |
| Maximum Input Voltage (Continuous) | 1000 Vrms or 1500 Vpeak, whichever is less |
| Maximum Continuous Input Current (2 A Element) | 3 Arms or 6 Apeak, whichever is less |
| Maximum Continuous Input Current (30 A Element) | 33 Arms or 150 Apeak, whichever is less |
| A/D Converter Resolution | 16-bit |
| Sampling Rate | Approx. 200 kS/s |
| External Current Sensor Input Impedance | 1 MΩ (approx. 100 pF) |
| Voltage Input Terminal Type | Safety terminal (female) |
| Current Input Terminal Type | Safety terminal (female) |
Measurement Accuracy
| Parameter | Value |
|---|---|
| Basic Voltage Accuracy (AC, 50/60 Hz) | ±(0.01% of reading + 0.03% of range) |
| Basic Voltage Accuracy (DC) | ±(0.05% of reading + 0.05% of range) |
| Basic Current Accuracy (AC, 50/60 Hz) | ±(0.01% of reading + 0.03% of range) |
| Basic Current Accuracy (DC, 2 A Element) | ±(0.05% of reading + 0.05% of range) |
| Basic Current Accuracy (DC, 30 A Element) | ±(0.05% of reading + 0.1% of range) |
| Basic Active Power Accuracy (AC, 50/60 Hz) | ±(0.02% of reading + 0.04% of range) |
| Basic Active Power Accuracy (DC, 2 A Element) | ±(0.05% of reading + 0.05% of range) |
| Basic Active Power Accuracy (DC, 30 A Element) | ±(0.05% of reading + 0.1% of range) |
| Frequency Bandwidth | DC, 0.1 Hz to 1 MHz |
| Influence of Power Factor | ±0.03% of S (apparent power) when PF = 0 (at 50/60 Hz) |
| Influence of Common Mode Voltage | ±0.01% of range or less (1000 Vrms, 50/60 Hz) |
Measurement Parameters & Calculation Functions
| Parameter | Value |
|---|---|
| Voltage/Current Crest Factor | Selectable 3 or 6 |
| Frequency Measurement Range | 0.15 Hz to 1 MHz |
| Integration Accuracy | ±(Power/Current Accuracy + 0.02% of reading) |
| Integration Auto-Range | Supported |
| Efficiency Calculation | Up to 4 efficiency equations can be defined (eta1 to eta4) |
| User-Defined Calculations | Up to 20 equations (F1 to F20) |
Harmonic Measurement Capabilities
| Parameter | Value |
|---|---|
| Harmonic Measurement Frequency Range | Fundamental frequency from 10 Hz to 2.6 kHz (PLL synchronization) |
| Maximum Harmonic Order Analysed | Up to 100th order (fundamental frequency of 50/60 Hz) |
| Total Harmonic Distortion (THD) Calculations | IEC standard or CSA standard selectable |
| Dual Harmonic Measurement | Supported (with option /G6) |
Motor Evaluation Function (Option)
| Parameter | Value |
|---|---|
| Motor Channels Supported | 1 channel |
| Torque Sensor Input Type | Analog (DC voltage) or Pulse (frequency) |
| Speed Sensor Input Type | Analog (DC voltage) or Pulse (frequency) |
| Mechanical Power (Pm) Calculation | Pm = Speed * Torque * Constant |
| Electrical Angle Measurement Capability | Supported with option /MTR |
Display & User Interface
| Parameter | Value |
|---|---|
| Display Type | 8.4-inch color TFT LCD |
| Display Resolution | 640 × 480 pixels (VGA) |
| Display Update Rate | 50 ms to 20 s (selectable) |
| Numeric Display Formats | 4, 8, 16, All items, Single list, Dual list |
| Waveform Display Mode | Supported |
| Harmonic Bar Graph Display Mode | Supported |
| Vector Display Mode | Supported |
| Trend Display Mode | Supported |
Interfaces & Connectivity
| Parameter | Value |
|---|---|
| GP-IB Interface | IEEE-488.2 compliant |
| Ethernet Port | 100BASE-TX/10BASE-T |
| RS-232/Serial Interface | 9-pin D-sub (male) |
| USB PC Link Port (Device) | USB Type B (USB 1.1 compliant) |
| USB Storage Port (Host) | USB Type A (USB 1.1 compliant) |
| D/A Output Channels (Option) | 20 channels (with option /DA) |
| External Trigger Input | BNC terminal, TTL level |
| Video Output | VGA, 15-pin D-sub (female) |
Power Supply & Physical Specifications
| Parameter | Value |
|---|---|
| Line Voltage Frequency | 50/60 Hz |
| Supply Voltage Range | 100 to 240 VAC |
| Power Consumption (Max) | 150 VA |
| Warm-up Time | Approx. 30 minutes |
Environmental & Safety Standards
| Parameter | Value |
|---|---|
| Operating Temperature Range | 5 to 40 °C |
| Operating Humidity Range | 20% to 80% RH (no condensation) |
| Storage Temperature Range | -25 to 60 °C |
| Safety Standard Compliance | EN61010-1 |
| Measurement Category (CAT Rating) | CAT II 1000V |
| EMC Directive Compliance | EN61326-1 Class A |
Filters
| Parameter | Value |
|---|---|
| Line Filter Cutoff Frequencies | 500 Hz, 5.5 kHz, 50 kHz, 1 MHz |
| Frequency Filter Cutoff Frequencies | 100 Hz, 500 Hz, 2 kHz, 20 kHz |
Storage & Interface Options
| Parameter | Value |
|---|---|
| Internal Data Storage Capacity | Approx. 30 MB |
| PC Card Slot | Type II PC Card slot |
Measurement Options
| Parameter | Value |
|---|---|
| Voltage Fluctuation & Flicker Measurement | Compliant with IEC61000-3-3 and IEC61000-4-15 (option /FL) |
| Delta Calculation Functions | Line-to-line voltage, phase voltage, and neutral current calculations (option /DT) |
Physical Options
| Parameter | Value |
|---|---|
| Built-in Printer Specification | Thermal line dot printer, 112 mm paper width (option /B5) |
Environmental
| Parameter | Value |
|---|---|
| Operating Altitude | Up to 2000 m |
Accuracy Specifications
| Parameter | Value |
|---|---|
| Voltage/Current Temperature Coefficient | Add ±0.01% of reading/°C (within 5 to 18 °C or 28 to 40 °C) |
| Active Power Temperature Coefficient | Add ±0.02% of reading/°C (within 5 to 18 °C or 28 to 40 °C) |
| Influence of Self-Heating (30 A Element Current) | Add 0.004 × I² % of reading to current and active power accuracy (where I is the current in A) |
| Influence of Magnetic Field | Add ±0.1% of range or less (at 400 A/m, 50/60 Hz) |
Measurement
| Parameter | Value |
|---|---|
| Effective Measurement Range (Voltage/Current) | 1% to 110% of range (Crest Factor 3) |
| Effective Measurement Range (Power) | 1% to 121% of range (Crest Factor 3) |
| Integration Time Setting Range | 0 hours 00 minutes 00 seconds to 10000 hours 00 minutes 00 seconds |
| Data Update Rate Options | 50 ms, 100 ms, 250 ms, 500 ms, 1 s, 2 s, 5 s, 10 s, 20 s, and Auto |
Harmonic Measurement
| Parameter | Value |
|---|---|
| Advanced Harmonic Measurement Maximum Order | 500th order (with Option /G6, fundamental frequency 50/60 Hz) |
Motor Evaluation Option
| Parameter | Value |
|---|---|
| Speed Input Range (Analog) | ±1 V, ±2 V, ±5 V, ±10 V (with Option /MTR) |
| Torque Input Range (Analog) | ±1 V, ±2 V, ±5 V, ±10 V (with Option /MTR) |
| Speed/Torque Pulse Input Frequency Range | 2 Hz to 1 MHz (with Option /MTR) |
D/A Output
| Parameter | Value |
|---|---|
| D/A Output Resolution | 16-bit (with Option /DA) |
| D/A Output Voltage Range | ±5 V FS (approx. ±7.5 V maximum) |
Safety & General
| Parameter | Value |
|---|---|
| Insulation Resistance | 50 MΩ or more at 500 VDC (between input terminals and case, and between input elements) |
| Withstand Voltage | 5.55 kVAC for 1 minute (between input terminals and case) |
Technology
Precision Power Analyzer
Applications
Inverter evaluation, high-efficiency motor testing, power semiconductor loss measurement, calibration, and power grid quality testing