The Chroma 61502 is a high-performance programmable AC/DC power source designed for simulating various power line conditions and measuring electrical parameters. Delivering up to 1000 VA of AC power and 500 W of DC power, it is an essential instrument for R&D, QA, and production testing of electronic products.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GPIB, RS-232, Analog Programming Interface (APG) |
| Display | LCD Graphic Display |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 90 - 250 VAC, single-phase, 47 - 63 Hz |
| Operating Temperature | 0 to 40 °C |
| Dimensions (W×H×D) | 425 × 133 × 503 mm |
| Weight | 24 |
AC Output Specifications
| Parameter | Value |
|---|---|
| Maximum AC Power Rating | 1000 VA |
| Output Phase Configuration | Single Phase |
| AC Voltage Ranges | 150 V / 300 V |
| Maximum RMS Current (Low Range, 150V) | 8 A |
| Maximum RMS Current (High Range, 300V) | 4 A |
| Maximum Peak Current (Low Range, 150V) | 48 A |
| Maximum Peak Current (High Range, 300V) | 24 A |
| Frequency Range | DC, 15 Hz - 1000 Hz |
| Voltage Line Regulation | 0.1% |
| Voltage Load Regulation | 0.2% |
| Total Harmonic Distortion (THD) | < 0.3% at 50/60 Hz (linear load) |
DC Output Specifications
| Parameter | Value |
|---|---|
| Maximum DC Power Rating | 500 W |
| DC Voltage Ranges | 212 V / 424 V |
| Maximum DC Current (Low Range, 212V) | 4 A |
| Maximum DC Current (High Range, 424V) | 2 A |
Measurement & Readback
| Parameter | Value |
|---|---|
| Measurement & Readback Parameters | Voltage (RMS, Peak, DC), Current (RMS, Peak, DC), Power (Active, Apparent, Reactive), Power Factor, Crest Factor |
Protection Features
| Parameter | Value |
|---|---|
| Protection Features | Overvoltage (OVP), Overcurrent (OCP), Overpower (OPP), Overtemperature (OTP), Fan Fail |
Input Power Requirements
| Parameter | Value |
|---|---|
| Input Phase Configuration | Single Phase |
Physical & Environmental Specifications
| Parameter | Value |
|---|---|
| Rack Height Units | 3U |
Programming Resolution
| Parameter | Value |
|---|---|
| Voltage Programming Resolution (AC) | 0.1 V |
| Frequency Programming Resolution | 0.01 Hz (15.00 - 99.99 Hz), 0.1 Hz (100.0 - 999.9 Hz) |
Phase Angle Control
| Parameter | Value |
|---|---|
| Phase Angle Programming Range | 0 to 360° |
| Phase Angle Programming Resolution | 0.1° |
Programming Accuracy
| Parameter | Value |
|---|---|
| AC Voltage Programming Accuracy (45 - 65 Hz) | 0.15% of setting + 0.15% of F.S. |
| AC Voltage Programming Accuracy (15 - 1000 Hz) | 0.3% of setting + 0.3% of F.S. |
| Frequency Programming Accuracy | 0.1% |
Measurement Accuracy
| Parameter | Value |
|---|---|
| AC Voltage Measurement Accuracy (45 - 65 Hz) | 0.1% of rdg + 0.1% of F.S. |
| AC Voltage Measurement Accuracy (15 - 1000 Hz) | 0.3% of rdg + 0.3% of F.S. |
| DC Voltage Measurement Accuracy | 0.1% of reading + 0.1% of range |
| Power Measurement Accuracy (45 Hz - 65 Hz) | 0.2% of reading + 0.2% of range |
| Power Factor Measurement Range | 0.000 - 1.000 |
| Crest Factor Measurement Range | 0.00 - 9.99 |
| Harmonic Current Measurement | Up to 40th order |
Output Performance
| Parameter | Value |
|---|---|
| RMS Current Crest Factor | 6 |
Power Input
| Parameter | Value |
|---|---|
| Maximum AC Input Current | 15 A max. @ 90 VAC, 7.5 A max. @ 180 VAC |
| AC Input Frequency Range | 47 to 63 Hz |
Environmental
| Parameter | Value |
|---|---|
| Storage Temperature | -40 to 85 °C |
| Operating Humidity | 0 to 90% RH (non-condensing) |
General Features
| Parameter | Value |
|---|---|
| Remote Sense Compensation | 5 V (maximum voltage drop per line) |
Control & Interfaces
| Parameter | Value |
|---|---|
| External Analog Programming (APG) Input | 0 to 5 V or 0 to 10 V for 0 to Full Scale output |
Output Specifications
| Parameter | Value |
|---|---|
| DC Voltage Programming Accuracy | 0.2% of reading + 0.2% of range |
| Voltage Programming Resolution | 0.1 V |
| Waveform Synthesizer Types | Sine, Square, Clipped-Sine, Arbitrary |
| Arbitrary Waveform Storage | 30 waveforms |
Transient Simulation
| Parameter | Value |
|---|---|
| Transient Simulation Modes | LIST, PULSE, STEP |
| Inter-Harmonic Sweep Frequency Range | 15 Hz - 1000 Hz |
Technology
Switch-mode AC Power Source
Applications
Power line disturbance simulation, harmonic distortion testing, and AC/DC power testing
Looking for the Chroma 61502?
Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.
Selling this kind of equipment? Sell with us