The EIP Microwave 575 is a legacy high-performance microwave frequency counter featuring automatic source locking capabilities from 10 Hz up to 18 GHz. Equipped with a YIG-tuned RF input filter, it provides high FM tolerance, excellent amplitude discrimination, and standard GPIB remote programming interface, making it ideal for phase-locking microwave signal sources and sweepers.

Specifications

General

ParameterValue
InterfacesGPIB (IEEE-488)
Display12-digit LED display

Physical

ParameterValue
Power Supply100 / 120 / 220 / 240 V AC (±10%), 50 to 60 Hz
Operating Temperature0 to 50 °C
Dimensions (W×H×D)432 × 89 × 457 mm
Weight9.1 kg

Frequency Measurement

ParameterValue
Frequency Range - Band 110 Hz to 100 MHz
Frequency Range - Band 210 MHz to 1 GHz
Frequency Range - Band 3 (Microwave)1 GHz to 18 GHz
Sensitivity - Band 125 mV rms
Sensitivity - Band 2-20 dBm
Sensitivity - Band 3-25 dBm (1 GHz to 12.4 GHz), -20 dBm (12.4 GHz to 18 GHz)
Input Impedance - Band 11 MΩ shunted by 25 pF
Input Impedance - Band 250 Ω nominal
Input Impedance - Band 350 Ω nominal
Input CouplingAC-coupled (all bands)
Input Connector - Band 1BNC female
Input Connector - Band 2BNC female
Input Connector - Band 3Precision Type N female
Maximum Input Level - Band 3+10 dBm
Damage Level - Band 3+40 dBm (10 W) continuous
ResolutionSelectable 1 Hz to 1 GHz
Measurement Time1 ms for 1 kHz resolution, 1 s for 1 Hz resolution
FM ToleranceUp to 20 MHz p-p
Amplitude Discrimination10 dB for signals separated by > 200 MHz
Input PreselectorYIG-tuned RF filter

Source Locking & Control

ParameterValue
Source Locking Frequency Range10 MHz to 18 GHz
Lock Resolution10 kHz
DAC Control Voltage Output±10 V

Time Base & Reference Oscillator

ParameterValue
Internal Reference Frequency10 MHz
External Reference Input10 MHz, 1 V p-p minimum into 50 Ω
Internal Reference Output10 MHz, 1 V p-p minimum into 50 Ω

Environmental & Reliability

ParameterValue
Storage Temperature Range-40 °C to +75 °C

Options & Accessories

ParameterValue
Option 01High Stability Oven Timebase
Option 02Rear Panel Input Configuration

Power Requirements

ParameterValue
Line Voltage100 / 120 / 220 / 240 VAC ±10% (rear panel selectable)
Line Frequency47 to 440 Hz
Power Consumption120 VA maximum

Environmental

ParameterValue
Operating HumidityUp to 95% relative humidity (non-condensing) at +40 °C
Operating AltitudeUp to 3,000 m (10,000 ft)

Source Locking

ParameterValue
Source Modulation Sensitivity Range0.1 to 100 MHz/V (either polarity)
Lock Voltage Range-10 V to +10 V
Lock Output Impedance100 Ohm nominal
DAC Resolution12-bit

Options

ParameterValue
Option 09Option 02 = Rear Panel Inputs (moves all front panel inputs to the rear panel)
Option 10Chassis Slides

Display & Controls

ParameterValue
Display Type12-digit LED

Input Band 2

ParameterValue
Damage Level - Band 2+30 dBm (1 W) continuous

Input Band 3

ParameterValue
Preselector TypeYIG-tuned automatic tracking preselector

Inputs & Outputs

ParameterValue
GP-IB Connector24-pin IEEE-488 (rear panel)
Lock Output ConnectorBNC female (rear panel)
External Reference Input ConnectorBNC female (rear panel)
Internal Reference Output ConnectorBNC female (rear panel)

Technology

YIG-tuned filter, automatic phase-locked loop (PLL) source locking

Applications

Microwave frequency measurement, automatic signal source locking and frequency stabilization