The Keithley 2303 is a 45W High-Speed Battery Simulating DC Power Supply designed for testing battery-operated, wireless communication devices. It is optimized to provide outstanding voltage stability during fast pulse load changes, such as those found in cellular devices. It features precision readback of load currents (including short pulses), is capable of sinking current to simulate a discharged battery, and offers a continuous output of 15V at 3A or 9V at 5A.

Specifications

General

ParameterValue
InterfacesGPIB (IEEE-488)
DisplayDual-line Vacuum Fluorescent Display (VFD)
Standard Warranty1 year

Physical

ParameterValue
Power Supply100V / 120V / 220V / 240V AC (switch-selectable), 50/60 Hz, 150 VA max
Operating Temperature0 to 50 °C
Dimensions (W×H×D)213 mm × 89 mm × 411 mm
Weight5.4 kg

DC Output Specifications

ParameterValue
Output Voltage Range0 to 15 V DC
Output Current Range0 to 3 A DC
Maximum Output Power45 W
Sinking Current Range0 to 2 A DC
Voltage Programming Accuracy±(0.05% + 10 mV)
Voltage Programming Resolution5 mV
Current Limit Programming Range0 to 3.1 A
Current Limit Programming Accuracy±(0.16% + 5 mA)
Current Limit Programming Resolution1.25 mA
Voltage Line Regulation±(0.01% + 2 mV)
Voltage Load Regulation±(0.01% + 2 mV)
Current Line Regulation±(0.01% + 1 mA)
Current Load Regulation±(0.01% + 1 mA)
Output Ripple and Noise (Peak-to-Peak)<3 mV p-p (20 Hz to 20 MHz)
Output Ripple and Noise (RMS)<1 mV RMS (20 Hz to 20 MHz)

Transient Response

ParameterValue
Transient Voltage Recovery Time<40 µs
Transient Voltage Recovery Levelto within 50 mV of original level
Transient Voltage Drop<75 mV
Bandwidth SelectionHigh and Low settings

Current Measurement (Readback)

ParameterValue
Current Readback Ranges5 A, 5 mA, 500 µA
Current Readback Accuracy (5A Range)±(0.2% + 400 µA)
Current Readback Accuracy (5mA Range)±(0.2% + 1 µA)
Current Readback Accuracy (500µA Range)±(0.2% + 100 nA)
Current Readback Resolution (5mA Range)0.1 µA
Current Readback Resolution (500µA Range)10 nA
DC Current Sensitivity10 nA
Pulse Current Measurement ModesPulse Peak, Average, and Baseline
Pulse Current Trigger Level Range5 mA to 5 A (in 5 mA steps)
Pulse Current Integration Time Range33.3 µs to 833 ms

Current Measurement (Readback

ParameterValue
Current Readback Resolution (5A Range)100 µA

Voltage Measurement (Readback)

ParameterValue
Voltage Readback Range0 to 15 V DC
Voltage Readback Accuracy±(0.05% + 3 mV)
Voltage Readback Resolution1 mV
Remote Sense Voltage RangeUp to 15 V DC
Maximum Remote Sense Line Drop Compensation1 V per lead

Digital and Control Interfaces

ParameterValue
GPIB InterfaceIEEE-488.2 conforming
Programming LanguageSCPI (Standard Commands for Programmable Instruments)
Trigger Delay Range0 to 100 ms

Protection and Safety

ParameterValue
Overvoltage Protection (OVP) Range0 to 15 V (limit settings)
Output Enable/Disable ControlYes, front panel button and SCPI controllable

Power Requirements

ParameterValue
Input AC Voltage Range100V / 120V / 220V / 240V AC (switch-selectable)
Input Frequency Range50 Hz / 60 Hz
Maximum Power Consumption150 VA

Physical Specifications

ParameterValue
Width213 mm (8.4 in)
Height89 mm (3.5 in)
Depth411 mm (16.2 in)
Net Weight3.2 kg (7.1 lbs)
Shipping Weight5.4 kg (12 lbs)
Cooling MethodForced air (internal fan)
Rack Mounting ConfigurationsSingle or dual rack mount (2U high, half-rack width)

Environmental and Compliance

ParameterValue
Storage Temperature Range-20 °C to 70 °C
Operating Humidity Range0% to 70% RH, non-condensing (up to 35 °C)
Recommended Calibration Cycle1 year

Performance & Accuracy

ParameterValue
Pulse Current Measurement Accuracy (5A Range, >1ms)±(0.2% + 10mA)
Temperature Coefficient (Voltage Programming)±(0.005% + 2mV)/°C
Temperature Coefficient (Voltage Readback)±(0.005% + 2mV)/°C
Temperature Coefficient (Current Limit Programming)±(0.05% + 1mA)/°C
Temperature Coefficient (Current Readback, 5A Range)±(0.05% + 1mA)/°C
Temperature Coefficient (Current Readback, 5mA Range)±(0.05% + 1µA)/°C
Output Impedance0.01 Ω (typical at DC)
Overvoltage Protection Accuracy±(0.5% + 200mV)
Overvoltage Protection Response Time<150 µs (typical)

Remote Sensing

ParameterValue
Maximum Sense Lead Resistance0.5 Ω (per lead for rated accuracy)

Inputs & Outputs

ParameterValue
Output Connector8-pin rear-panel quick-disconnect screw terminal block
Trigger Link Connector8-pin micro-DIN

Power & Safety

ParameterValue
Isolation Voltage (Output to Chassis)150 VDC maximum
Warm-up Time1 hour
Mains Fuse (100V/120V)2.0 A, 250 V, slow-blow (5x20 mm)
Mains Fuse (220V/240V)1.0 A, 250 V, slow-blow (5x20 mm)

Environmental

ParameterValue
Maximum Operating Altitude2000 m

Output Specifications

ParameterValue
Number of Channels1

Measurement

ParameterValue
A/D Converter Resolution16-bit

Compliance

ParameterValue
Safety ComplianceConforms to European Union Directive 73/23/EEC (EN 61010-1)
EMC ComplianceConforms to European Union Directive 89/336/EEC (EN 55011, EN 50082-1)

Technology

Battery Simulating DC Power Supply

Applications

Battery simulation and power consumption testing for wireless and portable battery-powered devices