The Keithley 2510-AT Autotuning TEC SourceMeter is a specialized 50W temperature control instrument designed for testing laser diode modules. It combines thermoelectric cooler (TEC) control, temperature measurement, and automated PID parameter selection.

Specifications

General

ParameterValue
InterfacesGPIB (IEEE-488.2), RS-232, Trigger Link (8-pin micro-DIN), Digital I/O (DB-9)
Display12-character vacuum fluorescent display (VFD) with status indicators

Physical

ParameterValue
Power Supply100V to 240V AC, 50Hz or 60Hz, 120 VA maximum
Operating Temperature0°C to 50°C
Dimensions (W×H×D)213 mm × 89 mm × 370 mm
Weight3.2 kg
Form FactorHalf-rack width, 2U height

TEC Output & Control

ParameterValue
Maximum Output Power50 W
Current Limit Range0 to 5.25 A
Voltage Limit Range0 to 10.5 V
Control AlgorithmProportional-Integral-Derivative (PID) with Autotuning capability
Temperature Stability (1 Hour)±0.005 °C
Temperature Stability (24 Hours)±0.01 °C

Temperature Sensor Compatibility

ParameterValue
Thermistor Compatibility100 Ω to 100 kΩ (2-wire or 4-wire)
RTD Compatibility100 Ω Platinum (3-wire or 4-wire)
IC Sensor CompatibilityAD590, LM335
Temperature Display Resolution0.001 °C

System & Interfaces

ParameterValue
Analog Output Voltage Range0 to ±10 V (proportional to temperature)
Command Language SupportSCPI (Standard Commands for Programmable Instruments)

Environmental & Compliance

ParameterValue
Storage Temperature-25°C to 65°C
Operating Humidity Range70% RH non-condensing at 35°C

TEC Output

ParameterValue
Output Current Range-5.00 A to +5.00 A DC
Output Voltage Range-10.0 V to +10.0 V DC
Current Source Accuracy±(0.4% + 16 mA)

Measurements

ParameterValue
Voltage Measure Accuracy±(0.1% + 1 mV)
Current Measure Accuracy±(0.4% + 16 mA)
Voltage Measure Resolution300 µV (16-bit)
Current Measure Resolution150 µA (16-bit)

Sensor Interface

ParameterValue
Thermistor Measurement Range100 Ω to 100 kΩ
RTD Resistance Range100 Ω to 1 kΩ
Maximum Source Lead Resistance0.1 Ω per lead (4-wire source)
Maximum Sense Lead Resistance10 Ω per lead (4-wire sense)
Thermistor Excitation Current10 µA, 100 µA, 1 mA (range dependent)
RTD Excitation Current1 mA
RTD Types Supported100 Ω Platinum (Alpha = 0.00385, 0.003916, 0.00392)
IC Sensors SupportedAD590 (1 µA/K), LM335 (10 mV/K)

Control & Autotuning

ParameterValue
Tuning ModeAutotuning PID or Manual PID

Protection & Safety

ParameterValue
Protective LimitsVoltage limit, Current limit, High temperature limit, Low temperature limit, Open sensor detection

Connectivity

ParameterValue
Trigger Link Connector8-pin micro-DIN
Digital I/O Port4 open-collector outputs, 1 TTL input

Output Specifications

ParameterValue
TEC Output Ripple and Noise (0.1 Hz to 10 Hz)< 500 µA rms (typical)
TEC Output Ripple and Noise (10 Hz to 10 MHz)< 1.5 mA rms (typical)
TEC Output Resolution16-bit
Analog Output Resolution16-bit

Measurement Performance

ParameterValue
Thermistor Measurement Accuracy±(0.04% of reading + 1.5 Ω) (90-day, on 10 kΩ range)
RTD Measurement Accuracy±(0.06% of reading + 0.05 Ω) (90-day)
Analog Output Accuracy±(0.15% of output + 10 mV) (90-day)

Control Performance

ParameterValue
Autotuning MethodZiegler-Nichols (Z-N) / Modified Z-N

General Specifications

ParameterValue
Warm-up Time1 hour

Power Specifications

ParameterValue
Mains Power Frequency50 Hz / 60 Hz
Maximum Power Consumption120 VA

Technology

Thermoelectric Cooler (TEC) Source & Measure with Automated PID Tuning

Applications

Laser diode module characterization and temperature stabilization