The Keithley 617 is a high-performance programmable electrometer designed for highly sensitive measurements of voltage, current, resistance, and charge. Featuring a 4½-digit LED display, an integrated isolated 100V voltage source, and standard IEEE-488 (GPIB) connectivity, the Keithley 617 delivers the exceptional input impedance and low input bias current required for sensitive research and calibration environments.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | IEEE-488 (GPIB) |
| Display | 4½-digit LED with 2-digit exponent |
| Warm-up Time | 1 hour to rated accuracy |
| Standard Accessories | Model 6011 triaxial input cable |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 90–125 V AC / 180–250 V AC, 50–60 Hz, 35 VA max |
| Operating Temperature | 0°C to 50°C |
| Dimensions (W×H×D) | 216 mm × 127 mm × 359 mm |
| Weight | 2.9 kg |
General Measurement Capabilities
| Parameter | Value |
|---|---|
| Measurement Functions | DC Voltage, DC Current, Resistance (constant-current and constant-voltage), Charge |
| Display Type | LED, 4½-digit mantissa plus 2-digit exponent |
| Ranging Modes | Automatic and Manual |
| Data Store Buffer | 100 readings |
| Calibration | Digital calibration from front panel or IEEE-488 bus |
| Zero Correct | Front panel zero correct control |
| Baseline Suppression | One-button suppression from front panel or IEEE-488 bus |
| Triggering | One-shot front panel or bus control |
DC Voltage Measurements (Voltmeter)
| Parameter | Value |
|---|---|
| Voltage Measurement Range | 200 mV to 200 V |
| 200mV Range Resolution | 10 µV |
| 2V Range Resolution | 100 µV |
| 20V Range Resolution | 1 mV |
| 200V Range Resolution | 10 mV |
| Input Impedance | >200 TΩ |
| Input Bias Current | <5 fA at 23°C |
| Common Mode Rejection Ratio (CMRR) | >120 dB |
| Normal Mode Rejection Ratio (NMRR) | >60 dB at 50 Hz or 60 Hz |
DC Current Measurements (Ammeter)
| Parameter | Value |
|---|---|
| Current Measurement Range | 2 pA to 20 mA |
| 2pA Range Resolution | 100 aA |
| 20pA Range Resolution | 1 fA |
| 200pA Range Resolution | 10 fA |
| 2nA Range Resolution | 100 fA |
| 20nA Range Resolution | 1 pA |
| 200nA Range Resolution | 10 pA |
| 2µA Range Resolution | 100 pA |
| 20µA Range Resolution | 1 nA |
| 200µA Range Resolution | 10 nA |
| 2mA Range Resolution | 100 nA |
| 20mA Range Resolution | 1 µA |
| Input Voltage Burden | <1 mV (<3 mV on 20 mA range) |
Resistance Measurements (Ohmmeter)
| Parameter | Value |
|---|---|
| Resistance Measurement Range | 2 kΩ to 200 GΩ (up to 10^16 Ω with V-source) |
| 2kΩ Range Resolution | 100 mΩ |
| 20kΩ Range Resolution | 1 Ω |
| 200kΩ Range Resolution | 10 Ω |
| 2MΩ Range Resolution | 100 Ω |
| 20MΩ Range Resolution | 1 kΩ |
| 200MΩ Range Resolution | 10 kΩ |
| 2GΩ Range Resolution | 100 kΩ |
| 20GΩ Range Resolution | 1 MΩ |
| 200GΩ Range Resolution | 10 MΩ |
| Maximum Open Circuit Voltage | 250 V DC |
| Resistance Measurement Methods | Constant current and constant voltage |
Charge Measurements (Coulombmeter)
| Parameter | Value |
|---|---|
| Charge Measurement Range | 200 pC to 20 nC |
| 200pC Range Resolution | 10 fC |
| 2nC Range Resolution | 100 fC |
| 20nC Range Resolution | 1 pC |
Internal Voltage Source (V-Source)
| Parameter | Value |
|---|---|
| V-Source Output Voltage Range | -102 V to +102 V |
| V-Source Output Resolution | 5 mV steps on 10V range, 50 mV steps on 100V range |
| V-Source Configuration | Isolated from electrometer section |
Analog & Auxiliary Outputs
| Parameter | Value |
|---|---|
| Analog Outputs | Preamplifier output and 2V full range output on rear panel |
System Interfaces & Connectivity
| Parameter | Value |
|---|---|
| Guard Configuration | Selectable driven cable guard |
| Input Connector Type | 2-slot female triaxial |
Power and Environmental Specifications
| Parameter | Value |
|---|---|
| Power Consumption | 35 VA maximum |
| Line Voltage Selection | 90–125 V AC or 180–250 V AC (rear panel switch) |
| Line Frequency | 50 Hz to 60 Hz |
| Operating Humidity Range | <70% relative humidity up to 35°C |
| Storage Temperature Range | -25°C to 65°C |
Voltage Source
| Parameter | Value |
|---|---|
| Voltage Source Max Current | 2 mA (short circuit protected) |
| Voltage Source Accuracy (10V Range) | ±(0.15% + 10 mV) |
| Voltage Source Accuracy (100V Range) | ±(0.15% + 100 mV) |
| Voltage Source Temperature Coefficient | ±(0.005% + 100 µV)/°C on 10V range, ±(0.005% + 1 mV)/°C on 100V range |
| Voltage Source Output Resistance | < 0.1 Ω |
Protection
| Parameter | Value |
|---|---|
| Overload Protection (Volts) | 250 V peak, DC to 60 Hz continuous |
| Overload Protection (Amps) | 100 V peak on 2 pA to 200 nA ranges, 250 V peak on 2 µA to 2 mA ranges |
| Overload Protection (Ohms) | 250 V peak, DC to 60 Hz continuous |
| Overload Protection (Coulombs) | 100 V peak, DC to 60 Hz continuous |
Outputs
| Parameter | Value |
|---|---|
| Preamp Output Voltage | 1 V for full scale input (inverting) |
| Preamp Output Impedance | 1 kΩ |
| 2V Analog Output Voltage | 2 V for full scale display (non-inverting) |
| 2V Analog Output Impedance | 10 kΩ |
Interfaces
| Parameter | Value |
|---|---|
| GPIB Interface Functions | SH1, AH1, T5, TE0, L4, LE0, SR1, RL1, PP0, DC1, DT1, C0, E1 |
Performance
| Parameter | Value |
|---|---|
| Maximum Reading Rate | 18 readings per second (via GPIB) |
Voltage Measurement
| Parameter | Value |
|---|---|
| Voltage Measurement Accuracy (200mV Range) | ±(0.15% of reading + 4 counts), 1 year (18°C-28°C) |
| Voltage Measurement Accuracy (2V to 200V Ranges) | ±(0.05% of reading + 1 count), 1 year (18°C-28°C) |
| Input Capacitance | < 20 pF |
Current Measurement
| Parameter | Value |
|---|---|
| Current Measurement Accuracy (2pA Range) | ±(1.6% of reading + 6 counts), 1 year (18°C-28°C) |
| Current Measurement Accuracy (2nA to 200nA Ranges) | ±(0.25% of reading + 5 counts), 1 year (18°C-28°C) |
| Current Measurement Accuracy (2µA to 20mA Ranges) | ±(0.15% of reading + 5 counts), 1 year (18°C-28°C) |
Resistance Measurement
| Parameter | Value |
|---|---|
| Resistance Measurement Accuracy (2kΩ Range) | ±(0.2% of reading + 4 counts), 1 year (18°C-28°C) |
| Resistance Measurement Accuracy (20kΩ to 20MΩ Ranges) | ±(0.2% of reading + 1 count), 1 year (18°C-28°C) |
| Resistance Measurement Accuracy (20GΩ Range) | ±(1.5% of reading + 1 count) |
| Resistance Measurement Accuracy (200GΩ Range) | ±(2.0% of reading + 1 count) |
Charge Measurement
| Parameter | Value |
|---|---|
| Charge Measurement Accuracy (200pC Range) | ±(0.4% of reading + 4 counts), 1 year (18°C-28°C) |
| Charge Measurement Accuracy (2nC to 20nC Ranges) | ±(0.4% of reading + 1 count), 1 year (18°C-28°C) |
Rear Panel Connections
| Parameter | Value |
|---|---|
| GPIB Address Configuration | Selectable via rear panel DIP switches |
| External Trigger Input | BNC connector, TTL-compatible, active low |
| Meter Complete Output | BNC connector, TTL-compatible, active low pulse |
| Voltage Source Output Connector | Safety BNC (red) |
Technology
Solid-State Electrometer
Applications
Low-level current, high resistance, voltage, and charge measurements