The Keithley 6487 is a 5.5-digit picoammeter and voltage source, designed for high-resolution low-current measurements and high-resistance applications. It combines the capabilities of an electrometer-grade ammeter with a built-in ±500 V voltage source, making it ideal for characterizing high-resistance materials, leakage currents, and insulation resistance. It features measurement ranges from 2 nA to 20 mA with up to 10 fA resolution, low burden voltage, and rapid reading rates.

Specifications

General

ParameterValue
InterfacesIEEE-488 (GPIB), RS-232, Trigger Link
Display5.5-digit Vacuum Fluorescent Display (VFD)
Display Resolution5½ digits

Physical

ParameterValue
Power Supply100-120 V / 220-240 V, 50/60/400 Hz, 50 VA max
Operating Temperature0 to 50
Dimensions (W×H×D)89 × 213 × 370
Weight4.7 kg

Current Measurement Specifications

ParameterValue
Current Ranges2 nA, 20 nA, 200 nA, 2 µA, 20 µA, 200 µA, 2 mA, 20 mA
Current Resolution10 fA (on 2 nA range) to 100 nA (on 20 mA range)
Current Accuracy (1 Year)±(0.3% + 400 fA) on 2 nA range to ±(0.1% + 1 µA) on 20 mA range
Burden Voltage< 200 µV (2 nA to 20 µA ranges); < 1 mV (200 µA to 20 mA ranges)
Input Bias Current< 3 fA at 23 °C

Voltage Source Specifications

ParameterValue
Voltage Ranges±10 V, ±50 V, ±500 V
Voltage Resolution1 mV (10 V range), 5 mV (50 V range), 50 mV (500 V range)
Voltage Accuracy (1 Year)±(0.1% + 1 mV) on 10 V range; ±(0.1% + 4 mV) on 50 V range; ±(0.1% + 40 mV) on 500 V range
Maximum Output Current25 mA (10 V range), 2.5 mA (500 V range)

Resistance Measurement Specifications

ParameterValue
Resistance Measurement MethodAlternating Voltage Method (supported via voltage source synchronization)

Measurement Speed and Timing

ParameterValue
Maximum Reading RateUp to 1000 readings/s
Buffer Size / Memory Capacity3000 readings

Connectivity and Interfaces

ParameterValue
Input Connector Type3-lug Triax (Current Input)
Analog Output0 to ±2 V for full scale input; 1 kΩ output impedance

Environmental and Compliance

ParameterValue
Storage Temperature-25 °C to 65 °C
Warm-up Time1 hour
Calibration Cycle1 year

Physical and Power

ParameterValue
Rack Mount CompatibilityStandard half-rack width

Performance

ParameterValue
Resistance Measurement RangeUp to 5 × 10^14 Ω
Overrange105% of range on all ranges

Protection & Isolation

ParameterValue
Ammeter Input Protection505V DC
Isolation (LO to Earth)500V peak maximum

Environmental

ParameterValue
Operating AltitudeMaximum 2000 m

Compliance

ParameterValue
Safety ComplianceConforms to European Union Low Voltage Directive
EMC ComplianceConforms to European Union EMC Directive

Measurement Features

ParameterValue
Analog DampingSelectable On / Off
Alternating Voltage MethodYes (cancels background current errors for high resistance measurements)

Safety / Protection

ParameterValue
Hardware InterlockYes, rear panel connection (required to enable voltage source)

Inputs & Outputs

ParameterValue
TriggeringKeithley Trigger Link

Technology

Picoammeter

Applications

Low Current Measurement, High Resistance Measurement, Insulation Testing, Leakage Current Testing

Looking for the Keithley 6487?

Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.