The Keithley 6517B is a 5½-digit electrometer and high-resistance meter designed for low-current, high-resistance, voltage, and charge measurements. It combines highly sensitive measurement capabilities with a built-in dual-range 1000 V DC voltage source, making it a standard for material characterization, resistivity measurements, and component testing.

Specifications

General

ParameterValue
InterfacesGPIB (IEEE-488.2), RS-232, Digital I/O, Trigger Link, Safety Interlock
Display5.5-digit Vacuum Fluorescent Display (VFD)
Emulation ModesKeithley 6517

Physical

ParameterValue
Power Supply100 V to 240 V AC, 50 Hz to 60 Hz, 100 VA maximum
Operating Temperature0°C to 50°C
Dimensions (W×H×D)214 mm × 90 mm × 369 mm
Weight5.4

Resistance Measurement

ParameterValue
Resistance Measurement Range100 Ω to 10^16 Ω
Resistance Display ResolutionUp to 5½ digits

Current Measurement

ParameterValue
Current Measurement Ranges20 pA, 200 pA, 2 nA, 20 nA, 200 nA, 2 µA, 20 µA, 200 µA, 2 mA, 20 mA
Minimum Current Resolution100 aA
Input Bias Current<3 fA
Current Measurement Accuracy (20 pA range)±(1.0% + 8 fA)
Current Measurement Accuracy (200 pA range)±(1.0% + 10 fA)
Current Measurement Accuracy (2 nA range)±(0.2% + 500 fA)
Current Measurement Accuracy (20 nA range)±(0.1% + 500 fA)
Current Measurement Accuracy (200 nA range)±(0.1% + 5 pA)
Current Measurement Accuracy (2 µA range)±(0.1% + 50 pA)
Current Measurement Accuracy (20 µA range)±(0.1% + 500 pA)
Current Measurement Accuracy (200 µA range)±(0.1% + 5 nA)
Current Measurement Accuracy (2 mA range)±(0.1% + 50 nA)
Current Measurement Accuracy (20 mA range)±(0.1% + 500 nA)
Input Voltage Burden<20 µV (<100 µV on 20 mA range)

Voltage Measurement

ParameterValue
Voltage Measurement Ranges2 V, 20 V, 200 V
Voltage Measurement Accuracy (2 V range)±(0.025% + 4 counts)
Voltage Measurement Accuracy (20 V range)±(0.025% + 3 counts)
Voltage Measurement Accuracy (200 V range)±(0.06% + 3 counts)
Voltage Measurement Resolution10 µV (on 2 V range)
Input Impedance>200 TΩ in parallel with <20 pF

Charge Measurement

ParameterValue
Charge Measurement Ranges2 nC, 20 nC, 200 nC, 2 µC
Charge Measurement Accuracy±(0.4% + 4 counts)
Charge Measurement Resolution10 fC (on 2 nC range)

DC Voltage Source

ParameterValue
Voltage Source Output Ranges±100 V, ±1000 V
Voltage Source Accuracy (100 V range)±(0.15% + 10 mV)
Voltage Source Accuracy (1000 V range)±(0.15% + 100 mV)
Voltage Source Resolution (100 V range)5 mV
Voltage Source Resolution (1000 V range)50 mV
Maximum Source Current (100 V range)10 mA
Maximum Source Current (1000 V range)1 mA
Current Limit (Compliance)Programmable (up to 10 mA on 100 V range, up to 1 mA on 1000 V range)

Measurement Timing and Speed

ParameterValue
Maximum Measurement RateUp to 425 readings/s

Measurement Support and Advanced Functions

ParameterValue
Resistivity CalculationsVolume Resistivity, Surface Resistivity (with compatible fixtures)
Built-in Test SequencesCapacitor Leakage, Diode Leakage, Resistivity, Surface Insulation Resistance (SIR), Voltage Sweep
Mathematical FunctionsmX+b, Percent, Reciprocal (1/X), Logarithmic
Limit TestingGo/No-Go testing with high/low limit outputs
Internal Memory CapacityUp to 50,000 readings
Temperature Measurement Range-25°C to 150°C (with Model 6517-TP probe)
Humidity Measurement Range0% to 100% RH (with Model 6517-RH probe)

Connectivity and Interfaces

ParameterValue
Input Connector3-slot Triaxial
Analog Output2 V full scale (non-inverting)
Safety Interlock4-pin

Power and Physical Characteristics

ParameterValue
Rack Mount CompatibilityYes (using optional rack mount kits)

Environmental and Safety Compliance

ParameterValue
Operating Humidity Range0% to 70% RH (non-condensing) up to 35°C
Storage Temperature Range-25°C to 65°C
Warm-up Time1 hour to rated accuracy

Accessories and Configuration Options

ParameterValue
Compatible Resistivity Test FixtureKeithley Model 8009
Compatible Temperature ProbeKeithley Model 6517-TP
Compatible Humidity ProbeKeithley Model 6517-RH

Voltage Source

ParameterValue
Voltage Source Load Regulation (100V Range)< 0.005% of range + 2 mV (for 0 to 20 mA load change)
Voltage Source Load Regulation (1000V Range)< 0.005% of range + 20 mV (for 0 to 1 mA load change)
Voltage Source Noise (100V Range)< 1.5 mV p-p (10 Hz to 1 MHz)
Voltage Source Noise (1000V Range)< 3.0 mV p-p (10 Hz to 1 MHz)
Voltage Source Settling Time< 8 ms (100 V range), < 50 ms (1000 V range)
Voltage Source Temperature Coefficient±(0.005% of setting + 1 mV)/°C (100 V range), ±(0.005% of setting + 10 mV)/°C (1000 V range)

Performance

ParameterValue
Common Mode Rejection Ratio (CMRR)> 120 dB (at DC, 50 Hz or 60 Hz with 1 kΩ in LO lead)
Normal Mode Rejection Ratio (NMRR)> 60 dB (at 50 Hz or 60 Hz, 1 PLC or greater)
A/D Converter Resolution20-bit
A/D Converter Integration Time0.01 PLC to 10 PLC

Inputs & Outputs

ParameterValue
Digital I/O Outputs4 open-collector outputs (100 mA max sink current, 30 V max clamp voltage)
Digital I/O Inputs1 TTL-compatible input
Trigger Link6 independent trigger lines

Measurement Features

ParameterValue
High Resistance Measurement MethodAlternating Polarity Method

Analog Outputs

ParameterValue
2V Analog Output Level±2.0 V full scale (non-inverting)
Preamp Output Level±2.0 V full scale (inverting)

Environmental

ParameterValue
Operating AltitudeUp to 2000 m (6562 ft) above sea level
Storage AltitudeUp to 12,000 m

Standards & Compliance

ParameterValue
Safety ConformanceConforms to European Union Directive 73/23/EEC, EN 61010-1
EMC ConformanceConforms to European Union Directive 89/336/EEC, EN 61326-1

Technology

Electrometer / Megohmmeter

Applications

High-resistance materials testing, low-current measurement, sensor characterization, and insulator testing