The Keysight 16034E is a high-precision SMD test fixture designed for stable and accurate impedance measurements of surface-mount components. Operating from DC up to 40 MHz, this 4-terminal pair fixture accommodates a wide range of SMD component sizes with its simple, adjustable slide mechanism, making it highly compatible with Keysight LCR meters and impedance analyzers.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | 4-Terminal Pair (BNC) |
| Furnished Accessories | Shorting plate (16034-60011), Shorting plate (16034-60012), Shorting plate (16034-60013), Shorting plate (16034-60014), Operating Manual |
Physical
| Parameter | Value |
|---|---|
| Operating Temperature | 0 to 55 °C |
| Dimensions (W×H×D) | 128 mm × 60 mm × 71 mm |
| Weight | 0.27 |
| Electrode Clamping Mechanism | Spring-loaded sliding contact |
Electrical Specifications
| Parameter | Value |
|---|---|
| Frequency Range | DC to 40 MHz |
| Maximum Voltage | ±40 V peak max (AC+DC) |
| Residual Resistance (R_s) | < 20 mΩ |
| Residual Inductance (L_s) | < 20 nH |
| Stray Capacitance (C_o) | < 1.5 pF |
Instrument Connections
| Parameter | Value |
|---|---|
| Terminal Configuration | 4-Terminal Pair |
| Connector Type to Instrument | BNC |
DUT Compatibility
| Parameter | Value |
|---|---|
| Compatible SMD Case Sizes (Metric) | 1608 (metric) to 8080 (metric) |
| Compatible SMD Case Sizes (Imperial) | 0603 (imperial) to 3131 (imperial) |
| Minimum Component Length | 1.6 mm |
| Maximum Component Length | 8 mm |
| Minimum Component Width | 0.8 mm |
| Maximum Component Width | 8 mm |
| Maximum Component Height | 8 mm |
Physical and Environmental
| Parameter | Value |
|---|---|
| Operating Temperature Range | 0 °C to 55 °C |
| Operating Humidity Range (Non-Condensing) | ≤ 95% RH @ 40 °C |
Instrument Compatibility
| Parameter | Value |
|---|---|
| Compatible LCR Meters | Keysight E4980A, E4980AL, HP 4284A, HP 4285A, HP 4263B |
| Compatible Impedance Analyzers | Keysight E4990A, HP 4294A |
Environmental
| Parameter | Value |
|---|---|
| Non-Operating Temperature Range | -55 °C to +85 °C |
| Non-Operating Humidity Range | ≤ 95% RH (at wet-bulb temperature ≤ 40 °C, non-condensing) |
| Operating Altitude | 0 to 2,000 m |
| Non-Operating Altitude | 0 to 4,572 m |
Measurement
| Parameter | Value |
|---|---|
| Compensation Types | Open and Short Compensation |
Compliance
| Parameter | Value |
|---|---|
| Safety Compliance | IEC 61010-1 / EN 61010-1 |
Technology
SMD Test Fixture
Applications
Impedance and LCR measurements of surface mount devices (SMD)
Looking for the Keysight Technologies (Agilent HP) 16034E?
Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.
Selling this kind of equipment? Sell with us