The Agilent 1680A is a standalone, 136-channel logic analyzer in the 1680 Series, featuring 800 MHz timing and 200 MHz state speeds. Designed with a built-in 12.1-inch color flat-panel display and a Windows-based user interface, it delivers high performance and ease of use in a self-contained benchtop form factor.

Specifications

General

ParameterValue
InterfacesLAN (10/100 Base-T RJ-45), USB (1.1), Parallel (LPT), Serial (RS-232), SVGA Video Out, PS/2 Keyboard & Mouse
Display12.1-inch active-matrix color TFT flat panel, 800 x 600 resolution

Physical

ParameterValue
Power Supply100 to 240 VAC, 47 to 63 Hz (or 115 VAC at 400 Hz), 320 W maximum
Operating Temperature0 to +45 °C
Dimensions (W×H×D)426 mm × 324 mm × 378 mm
Weight12.9

Acquisition and Sampling

ParameterValue
Acquisition Channels136 channels
Maximum State Clock Rate200 MHz
Maximum Conventional Timing Sample Rate400 MHz (full channel)
Maximum Transitional Timing Sample Rate400 MHz (half channel)
Standard Memory Depth (State/Timing)1 M per channel (2 M in half-channel timing mode)
Memory Depth Option 0024 M per channel (8 M in half-channel timing mode)
Setup and Hold Time Window1.5 ns
Threshold Voltage Range-3.0 V to +5.0 V
Threshold Setting Resolution10 mV
Threshold Setting Accuracy±(100 mV + 3% of setting)
Maximum Input Voltage±40 V peak

Triggering Capabilities

ParameterValue
Trigger Sequence Levels16 levels
Pattern Detectors16
Range Detectors4
Glitch TriggeringAvailable on timing channels
Trigger Event Counter Range1 to 2,000,000,000
Trigger Delay Range (by Time)Up to 10,000 seconds
Trigger Delay Range (by Events)1 to 2,000,000,000 events

Probing and Input Characteristics

ParameterValue
Input Impedance (Resistance)100 kΩ ± 2% (probe dependent)
Input Impedance (Capacitance)1.5 pF to 8 pF (probe dependent)
Minimum Input Voltage Swing500 mV peak-to-peak

Controller and Storage

ParameterValue
Operating SystemWindows XP Professional
Internal Storage Type & CapacityHard Disk Drive (≥ 20 GB configuration dependent)

Connectivity and Interfaces

ParameterValue
Oscilloscope Time CorrelationCompatible with Agilent E5850A Time Correlation Fixture for Infiniium Oscilloscopes

Environmental and Safety Compliance

ParameterValue
Storage Temperature Range-40 °C to +75 °C
Operating Humidity RangeUp to 95% relative humidity (non-condensing)

System Architecture

ParameterValue
System ProcessorIntel Celeron 2.0 GHz
System RAM512 MB

Timing Analysis

ParameterValue
Glitch Timing Maximum Sample Rate200 MHz (half-channel)
Minimum Detectable Glitch Width3.0 ns
Time Interval Accuracy±(1 sample period + 0.01% of interval + 1.0 ns)

State Analysis

ParameterValue
State Clock Inputs4
State Clock Qualifiers4

Triggering

ParameterValue
Timer Terms2 (8 ns to 34.3 s range)
Edge Terms2

Environmental

ParameterValue
Maximum Operating Altitude3,000 m
Maximum Non-Operating Altitude15,300 m

Inputs & Outputs

ParameterValue
External Trigger InputBNC, TTL compatible, approximately 1.5 kOhm input impedance
External Trigger OutputBNC, TTL level into 50 Ohm
VGA Port15-pin D-sub for external monitor
USB Ports2 ports, USB 1.1 compliant
LAN PortRJ-45, 10/100Base-T
Serial Port9-pin D-sub, RS-232
Parallel Port25-pin D-sub
Probe Connectors8 standard 40-pin connectors

Technology

Logic Analysis

Applications

Digital circuit debugging, embedded system troubleshooting, and state/timing analysis