The Keysight (Agilent/HP) 3784A is a high-performance Bit Error Rate (BER) and jitter test set designed for manufacturing, commissioning, and maintenance of telecommunication networks and equipment operating at CEPT interface rates (704 kb/s, 2, 8, and 34 Mb/s). Featuring a built-in synthesized clock source, TTL/ECL binary interfaces for versatile BER testing from 1 kb/s to 50 Mb/s, and options for 64 kb/s codirectional and jitter interfaces, it delivers robust automated testing of jitter tolerance, jitter transfer functions, and comprehensive error analysis.

Specifications

General

ParameterValue
DisplayCRT display

Physical

ParameterValue
Power Supply100 / 120 / 220 / 240 V AC, 48 to 66 Hz
Operating Temperature0 to 55 °C
Dimensions (W×H×D)425 mm × 188 mm × 530 mm
Weight19 kg

Receiver and Transmitter Interfaces

ParameterValue
Supported CEPT Bit Rates704 kb/s, 2 Mb/s (2.048 Mb/s), 8 Mb/s (8.448 Mb/s)
General-Purpose BER Rate Range1 kb/s to 50 Mb/s
Binary InterfacesTTL, ECL
Optional Interfaces64 kb/s codirectional interface (Option 002)

Clocking and Synchronization

ParameterValue
Clock Source TypeInternal synthesized clock source

Error Insertion and Measurement

ParameterValue
Error Analysis ParametersError count, error ratio, error and error-free intervals (seconds or deciseconds), % unavailability, % errored seconds, % severely errored seconds, % degraded minutes
Measurement ModeSimultaneous measurement of all error analysis parameters

Jitter and Wander Measurements

ParameterValue
Jitter Measurement ParametersPeak-to-peak amplitude, jitter hit count, jitter hit and hit-free intervals (seconds or deciseconds)
Automated Jitter MeasurementsFully automated jitter tolerance and transfer function measurements (up to and beyond CCITT limits)
Through-Data Jitter ModulationSupported (adds jitter to a fully-framed test signal passing through)
Jitter and Error CorrelationCorrelation of jitter hits with error bursts

Framing and Overhead Analysis

ParameterValue
In-Service MonitoringLine code error detection for monitoring in-service performance

System Control and Connectivity

ParameterValue
Results LoggingUnattended long-term measurement logging to external printer
Ease-of-Use FeaturesMeasurement presets, automatic receiver set-up, pass/fail thresholds

Receiver Specifications

ParameterValue
Receiver Input Impedance75 Ω unbalanced (BNC), 120 Ω balanced (Siemens 3-pin)

Transmitter Specifications

ParameterValue
Transmitter Output Impedance75 Ω unbalanced (BNC), 120 Ω balanced (Siemens 3-pin)
Line CodingHDB3, AMI
Internal Clock Accuracy±10 ppm

Test Patterns

ParameterValue
PRBS Test Patterns2^9-1, 2^11-1, 2^15-1, 2^20-1, 2^23-1

Jitter Generator

ParameterValue
Jitter Modulation SourcesInternal synthesizer, external input

Transmitter

ParameterValue
Transmitter Clock Offset±50 ppm in 1 ppm steps

Receiver

ParameterValue
Receiver Input ModesTerminate, Monitor, Protected Monitor

Transmitter / Error Generation

ParameterValue
Error Insertion RatesSingle, 1E-3, 1E-4, 1E-5, 1E-6, 1E-7
Error Insertion TypesBit, Code (bipolar violation)

Compliance

ParameterValue
Standards ComplianceITU-T G.703, G.821, G.823, O.171

Options

ParameterValue
Option 001Adds 704 kb/s operating rate

Technology

Bit Error Rate & Jitter Testing

Applications

Commissioning, manufacturing, and maintenance of CEPT telecom network equipment