The Keysight Agilent HP 6030A is a 1200 W, single-output, autoranging programmable DC power supply designed for automatic test systems. It provides high efficiency, GPIB programmability, analog control of output voltage and current, and extensive built-in measurements in a compact 3U rack-mount form factor.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GPIB (HP-IB), Analog Programming/Monitoring |
| Display | Dual 4-digit LED displays (voltage and current) |
| Recommended Calibration Interval | 1 year |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 120 VAC nominal (standard); 100 / 220 / 240 VAC options, 47-63 Hz, 2800 VA max |
| Operating Temperature | 0 to 55 °C |
| Dimensions (W×H×D) | 425.5 mm × 132.6 mm × 503.7 mm |
| Weight | 16.3 |
Output Ratings and Capabilities
| Parameter | Value |
|---|---|
| Number of Channels | 1 |
| Rated Output Voltage | 0 to 200 V |
| Rated Output Current | 0 to 17 A |
| Rated Output Power | 1000 W |
Load and Line Regulation
| Parameter | Value |
|---|---|
| Voltage Load Regulation | 0.01% + 15 mV |
| Current Load Regulation | 0.01% + 10 mA |
| Voltage Line Regulation | 0.01% + 10 mV |
| Current Line Regulation | 0.01% + 10 mA |
Ripple and Noise
| Parameter | Value |
|---|---|
| Constant Voltage Ripple and Noise (Vrms) | 22 mV |
| Constant Voltage Ripple and Noise (Vp-p) | 50 mV |
| Constant Current Ripple and Noise (Irms) | 15 mA |
Programming Accuracy and Resolution
| Parameter | Value |
|---|---|
| Voltage Programming Accuracy | 0.035% + 145 mV |
| Current Programming Accuracy | 0.2% + 25 mA |
| Voltage Programming Resolution | 50 mV |
| Current Programming Resolution | 4.25 mA |
| OVP Programming Accuracy | 1.6% + 1.2 V |
| OVP Programming Resolution | 1.2 V |
Readback Accuracy and Resolution
| Parameter | Value |
|---|---|
| Voltage Readback Accuracy | 0.08% + 80 mV |
| Current Readback Accuracy | 0.36% + 15 mA |
| Voltage Readback Resolution | 50 mV |
| Current Readback Resolution | 5 mA |
Protection Features
| Parameter | Value |
|---|---|
| Over-Voltage Protection (OVP) Range | 2.4 to 230 V |
System Connectivity and Interfaces
| Parameter | Value |
|---|---|
| GPIB (IEEE-488) Interface | Standard (HP-IB) |
| Analog Programming and Monitoring | 0 to 5 V, 0 to 10 V, 0 to 5 kΩ, or 0 to 10 kΩ control options |
| Remote Sensing Compensation Voltage | Up to 2 V drop per load lead |
AC Input Specifications
| Parameter | Value |
|---|---|
| AC Input Voltage Options | 100 VAC / 120 VAC / 220 VAC / 240 VAC (factory-configured options) |
| AC Input Frequency Range | 47 to 63 Hz |
Physical and Mechanical
| Parameter | Value |
|---|---|
| Form Factor | 3U rack-mount |
| Cooling System Design | Forced air cooling with internal fan, side/bottom intake and rear exhaust |
| Shipping Weight | 21.8 kg |
Environmental and Standards
| Parameter | Value |
|---|---|
| Storage Temperature Range | -40 to +75 °C |
Power Specifications
| Parameter | Value |
|---|---|
| AC Input Power (VA) | 2800 VA |
| AC Input Current | 24 A @ 120 VAC, 14 A @ 200 VAC, 13 A @ 220 VAC, 12 A @ 240 VAC |
Performance
| Parameter | Value |
|---|---|
| Temperature Coefficient (Voltage) | 0.01% + 3 mV per °C |
| Temperature Coefficient (Current) | 0.02% + 0.5 mA per °C |
| Command Processing Time | 15 ms (average time for output to change after receipt of GPIB command) |
| Output Rise Time (Full Load) | 100 ms |
| Output Rise Time (No Load) | 100 ms |
| Output Fall Time (Full Load) | 250 ms |
| Output Fall Time (No Load) | 6 s |
| Transient Recovery Time | 1 ms to recover within 150 mV of nominal output voltage following a load change |
Safety & Isolation
| Parameter | Value |
|---|---|
| Maximum Isolation Voltage | ±550 VDC |
Environmental
| Parameter | Value |
|---|---|
| Operating Altitude | Up to 2000 m |
| Operating Humidity | Up to 80% RH (non-condensing) |
Stability
| Parameter | Value |
|---|---|
| Output Voltage Drift | 0.03% + 5 mV (over 8 hours) |
| Output Current Drift | 0.03% + 3 mA (over 8 hours) |
Capability
| Parameter | Value |
|---|---|
| Series Connection Limit | Up to 2 units |
| Parallel Connection Limit | Up to 3 units |
Inputs & Outputs
| Parameter | Value |
|---|---|
| Analog Control Input Ranges | 0 to 5 V (voltage control) or 0 to 4 kΩ (resistance control) |
| Rear Panel Connections | GPIB (IEEE-488) connector, 15-pin analog control terminal block (J1), output bus bars |
Technology
Switch-mode / Autoranging
Applications
Automated test equipment (ATE), system power, industrial testing