- Home
- Manufacturers
- Keysight Technologies (Agilent HP)
- Keysight Technologies (Agilent HP) Power Supplies
Keysight Technologies (Agilent HP) Power Supplies
81 models with full specifications in Power Supplies.
This page summarizes Keysight (formerly Agilent/HP) DC power products that commonly appear in test laboratories and automated test equipment racks. It covers the principal families — benchtop bench supplies, modular N6700 mainframes with N67xx power modules, rack/system single‑output supplies for higher power, and companion electronic loads and AC sources. The text explains how the product families are organised, what functional differences to expect (programmability, interfaces, power density, autoranging vs fixed ranges), and which application spaces each family targets. The intended reader is an engineer or test‑system buyer choosing a supply or system component for bench work, ATE integration, or production test.
- N6700 mainframe slots
- 4 module slots (low‑profile mainframe)
- N3300A mainframe slots
- 6 module slots, up to 1800 W total (configuration dependent)
- N5700 Series (750W)
- compact 1U system supplies, 600 W–780 W (model dependent)
- N5700 Series (1500W)
- 2U single‑output supplies, up to 1560 W output power
All models
| Model | Type | Operating Temperature | Interfaces | Weight |
|---|---|---|---|---|
| N5700 Series - 750W | Agilent HP | 0 to 55 °C | GPIB, LAN, USB | 8.3 kg |
| 6620 Series - 25-105W | Agilent HP | 0 to 55 °C | GPIB (IEEE 488.2) | 18.1 kg |
| N5700 Series - 1500W | Agilent HP | 0 to 50 °C | GPIB, LAN, USB | 16.3 kg |
| 66300 Series - 40 - 100 W | Agilent HP | 0 to 55 °C | GPIB | — |
| E3600 Series - 30-60W | Agilent HP | 0 to 40 °C | GPIB (IEEE-488.2) standard; RS-232 (some models) | 6.8 to 7.7 kg |
| N6750 Series - 50W, 100W, 300W Modules | Agilent HP | 0 to 55 °C | Via N6700 series mainframe: LAN (LXI C), USB 2.0, GPIB | 1.0 to 1.3 kg (module dependent) |
| 66000 Series - 150W Modules | Agilent HP | 0 to 55 °C | None directly on module; controlled via mainframe's GPIB | 5.5 kg |
| E3640 Series - 30-80W | Agilent HP | 0 to 40 °C | GPIB, RS-232 | 4.7 - 4.9 kg |
| 6670 Series - 2000W | Agilent HP | 0 to 50 °C | GPIB, Analog (monitoring and control) | 37.2 kg |
| N6740 Series - 100W Modules | Agilent HP | 0 to 55 | Provided by mainframe (USB, LAN/LXI, GPIB) | 1.23 kg |
| N6730 Series - 50W Modules | Agilent HP | 0 to 55 | — | 1.23 kg |
| 6650 Series - 500W | Agilent HP | 0 to 55 | GPIB (IEEE-488), RS-232, Analog | — |
| N6700 Series - Mainframes and Systems | Agilent HP | 0 to 55 | GPIB, LAN, USB | — |
| 6680 Series - 5000W | Agilent HP | 0 °C to 50 °C | GPIB | — |
| 6640 Series - 200W | Agilent HP | 0 to +55 °C | GPIB, RS-232 | 9.0 kg |
| 6630 Series - 80-100W | Agilent HP | 0 to 55 | GPIB, RS-232 | 9.1 kg (net) |
| N6770 Series - 300W Modules | Agilent HP | 0 °C to 55 °C | — | — |
| 6570 Series - 2000W | Agilent HP | 0 to +55 | Analog programming (no standard digital interface) | 28.2 |
| 6550 Series - 500W | Agilent HP | 0 to 55 | Analog programming only | — |
| 6010 Series - 1200W | Agilent HP | — | None (No built-in computer interface) | — |
| 6540 Series - 200W | Agilent HP | 0 to 55 °C | — | 14.2 kg |
| 6610 Series - 40-50W | Agilent HP | 0 to 55 | GPIB, RS-232 | 8.85 |
| N6760 Series - 50W, 100W Modules | Agilent HP | 0 °C to 55 °C | — | — |
| 6690 Series - 6600W | Agilent HP | — | GPIB | — |
| E3631A | Agilent HP | 0 to 40 °C | GPIB, RS-232 | 8.2 kg |
| E3633A | Agilent HP | 0 to 40 | GPIB, RS-232 | 9.5 |
| N3302A | Electronic Loads | 0 °C to 55 °C | Via N3300A / N3301A mainframe (GPIB, RS-232) | 2.72 kg |
| E3648A | Agilent HP | 0 to 40 | GPIB (IEEE-488), RS-232 | 9.2 kg |
| N3300A | Electronic Loads | 0 to 55 | GPIB, RS-232 | 13.2 |
| N3304A | Agilent HP | 0 °C to 55 °C | — | 2.72 kg |
| N3306A | Electronic Loads | 0 to +55 | — | 4.08 kg |
| 3245A | Power Sources | — | — | — |
| 6032A | Agilent HP | 0 to 55 °C | GPIB (IEEE‑488); analog/resistance programming (remote control) | — |
| E3632A | Agilent HP | 0 °C to 40 °C | GPIB (IEEE‑488.2), RS‑232 | — |
| 6060B | Electronic Loads | 0 to 55 °C | GPIB (IEEE-488) | — |
| 6812B | AC Sources | — | — | — |
| E3620A | Agilent HP | 0 to 55 °C (current derated 3.3% per °C from 40°C to 55°C) | None (analog manual control only) | 5.5 kg |
| E3630A | Agilent HP | 0 to 40 °C | None (manual analog control only) | 3.8 kg |
| U8000 Series - 90-150W | Agilent HP | 0 °C to 40 °C | None (Non-programmable; features Kensington security lock slot for physical security) | 7.3 kg (U8001A) / 8.3 kg (U8002A) |
| 6063B | Electronic Loads | 0 to 55 °C | — | 9.6 kg |
| 66000 Series - 150W Mainframe | Agilent HP | 0 to 55 °C | GPIB (IEEE-488.2), Serial Link | — |
| 6813B | AC Sources | — | — | — |
| E3634A | Agilent HP | 0 to 40 °C | GPIB, RS-232 | 9.5 kg |
| E3649A | Agilent HP | — | GPIB, RS-232 | — |
| E3646A | Agilent HP | — | GPIB (IEEE-488) and RS-232 | 8.2 kg |
| N6756A | Agilent HP | 0 to 55 °C | GPIB, LAN, USB, LXI Class C (via mainframe) | — |
| 4142B | DC Sources | 5 °C to 40 °C | GPIB (HP-IB) | 15 kg |
| 6038A | Agilent HP | 0°C to 55°C | GPIB (IEEE-488), Analog/Resistance Control | 9.6 kg |
Looking for Keysight Technologies (Agilent HP) Power Supplies?
Tell us what you need. We're building a network of equipment dealers and will get back to you if we can help source it — no obligation.
Selling this kind of equipment? Sell with us
How Keysight’s power‑supply families are organised
Keysight’s offerings split into distinct use cases rather than a single linear product line. At the bench level you will find compact, standalone supplies and multi‑output bench models with built‑in meters and local controls. For system and ATE integration there are low‑profile modular mainframes that accept a variety of N67xx modules. For higher continuous power and rack integration there are single‑output system supplies rated from hundreds of watts up into multi‑kilowatt classes. Companion products include electronic load modules in N3300 mainframes and AC sources/power analyzers for AC or DC+AC test scenarios.
Examples to illustrate the structure
- Bench and small system instruments: E3600 and related benchtop models (for compact single‑ and multi‑output needs). The E3631A is an example of a compact triple‑output design used for lab work. The E3633A shows the dual‑range, higher‑power benchtop approach.
- Modular mainframe approach: the N6700 Series accommodates multiple N67xx class modules for flexible channel count and channel mix.
- High‑power single‑output systems: the 66xx and 68xx series units provide single outputs at much higher power and current for burn‑in and production test.
What distinguishes each family — capability checklist
Use these attributes to decide which family fits your requirements:
- Form factor and density: modular mainframes are chosen when you need multiple isolated channels in a compact chassis; rack/system single‑output units are for high continuous power per channel; benchtop units are for standalone lab use.
- Interfaces and automation: many Keysight system and benchtop models offer digital remote interfaces (GPIB, LAN, USB, RS‑232) and SCPI command support; modules rely on the mainframe for communications. Where instrument control must be integrated into test sequences, prefer units or mainframes that list GPIB/LAN/USB.
- Power and autoranging: autoranging supplies maintain a power envelope across a broad V/I combination; some system supplies and autoranging models are more appropriate when a wide V–I operating envelope is required, while fixed‑range supplies give simpler, often higher‑current outputs at a single voltage range.
- Measurement and precision: module‑based solutions such as the N6750, N6740 and N6760 classes are specified for low noise, fast programming and high readback accuracy when you need measurement‑grade outputs within an N6700 system.
Illustrative models and their roles
- N6700 Series mainframes host N6730/N6740/N6750/N6760/N6770 modules when a mix of precision, power and autoranging channels is needed in one chassis.
- N5700 Series (750W and 1500W variants) are compact system supplies intended where a single, higher‑power programmable DC output is required in a rack slot.
- 66xx and 67xx system series (for example 6640, 6650 or 6670) cover the middle to high power single‑output system market where built‑in measurements and digital interfaces are expected.
Selecting a Keysight supply for your application
Match the supply to the task using these practical criteria:
- Channel count and isolation: choose a modular N6700 approach when you need multiple isolated outputs and centralized communication. Modules (N6730/N6740/N6750/N6760/N6770) give per‑slot flexibility.
- Total and per‑channel power: for multi‑kW single outputs consider the higher‑power 66xx/67xx/68xx series; for compact rack density choose the N5700 750W or 1500W variants depending on power per rack unit.
- Programmability and interfaces: if automated control is required, explicit GPIB/LAN/USB or RS‑232 support matters — many system and bench models list those interfaces; modules rely on mainframe link interfaces.
- Measurement needs: when low noise and tight readback accuracy are required, opt for the high‑performance N67xx class modules intended for the N6700 platform.
Also consider complementary equipment: Keysight N3300A mainframes and N330x electronic load modules support dynamic load testing, and AC source/analyzer models such as 6812B/6813B are available when AC or combined DC/AC testing is required.
Popular models
Frequently asked questions
- When should I choose the N6700 modular approach instead of a standalone bench supply?
- Choose the N6700 Series mainframe when you need multiple, independently controllable DC outputs with centralized communication and timing. The N6700 accepts N67xx family modules so you can mix power/precision profiles in a single 1U chassis with four module slots.
- Which Keysight products are intended for multi‑kilowatt single‑output applications?
- The 66xx/67xx/68xx series cover higher single‑output power. Examples in the range include system supplies specified at 2000 W (6670 Series), 5000 W (6680 Series) and the 6600W class (6690 Series). These are intended for rack‑level, high‑power test and burn‑in.
- If I need programmable electronic loading for supply verification, which Keysight products apply?
- Use the N3300A electronic‑load mainframe with N330x load modules. The N3300A supports up to six module slots; modules such as the N3304A (300 W) and N3306A (600 W, 2‑slot) provide programmable CC/CV/CR modes and transient generation useful for supply and battery testing.