The Keysight/Agilent/HP 6032A is a single‑output, autoranging programmable DC system power supply in the 6030 Series. It provides up to 1064 W across a wide operating envelope with 0–60 V and 0–50 A ranges, GPIB control, analog/resistance programming, built‑in measurements, and support for series and auto‑parallel operation in large test systems.

Specifications

General

ParameterValue
InterfacesGPIB (IEEE‑488); analog/resistance programming (remote control)
DisplayDual 3.5‑digit LED meters (voltage and current)

Physical

ParameterValue
Power Supply100/120/220/240 VAC ±10%, 47–63 Hz
Operating Temperature0 to 55 °C
CoolingForced‑air (internal fan)

DC Output Specifications

ParameterValue
Output TypeSingle‑output autoranging DC
Number of Outputs1
Output Voltage Range0 – 60 V
Output Current Range0 – 50 A
Maximum Output Power1000 W (autoranging)
Operating ModesConstant Voltage (CV) / Constant Current (CC) with automatic crossover
Output Voltage Setting Range0 – 60 V
Output Current Setting Range0 – 50 A
Readback Voltage Range0 – 60 V
Readback Current Range0 – 50 A
Built‑in MeasurementsVoltage and current readback (metering)
Output On/Off ControlFront panel and remote (GPIB)
Autoranging Output CharacteristicMaintains up to 1000 W across the 0–60 V / 0–50 A operating envelope

Remote Sensing and Output Configuration

ParameterValue
Series Operation CapabilitySupported
Parallel Operation CapabilitySupported (auto‑parallel)
Remote Sense CapabilityYes (remote voltage sensing)

Connectivity and I/O

ParameterValue
GPIB (IEEE‑488) InterfaceProvided (remote programming and readback)
Output Termination StyleRear high‑current terminals/bus bars

Programming and Control

ParameterValue
Analog/Resistance ProgrammingSupported for voltage and current
Local/Remote Control SelectionFront panel or remote (GPIB/analog)

Protection and Safety Functions

ParameterValue
Short‑Circuit ProtectionInherent via CC mode (output withstands short)
Overcurrent ProtectionConstant current limiting (programmable)

User Interface

ParameterValue
Status IndicatorsCV/CC front‑panel annunciators

Protection

ParameterValue
Overvoltage ProtectionAdjustable OVP

Applications

Automated test systems; production test; high‑current/high‑power DC sourcing in system racks.