The Keysight Technologies (Agilent HP) 6035A is a high-performance 1064W, single-output autoranging DC system power supply designed for demanding test systems. Part of the industry-standard 6030 Series, the 6035A offers precise GPIB and analog programming of output voltage and current up to 500 V and 5 A, optimizing rack space and simplifying complex automated test environment setup.

Specifications

General

ParameterValue
InterfacesGPIB (IEEE-488), Analog
DisplayDual 3.5-digit LED displays for voltage and current
Warm-Up Time30 minutes

Physical

ParameterValue
Power Supply100 VAC / 120 VAC / 220 VAC / 240 VAC (option-dependent), 48 to 63 Hz
Operating Temperature0 to 55 °C
Dimensions (W×H×D)425.5 mm × 132.6 mm × 503.7 mm
Weight16.3

Output Ratings and Capabilities

ParameterValue
Number of Channels1
Rated Output Voltage0 to 500 V
Rated Output Current0 to 5 A
Rated Output Power1000 W
Output TypeAutoranging

Load and Line Regulation

ParameterValue
Voltage Load Regulation0.01% + 25 mV
Current Load Regulation0.01% + 5 mA
Voltage Line Regulation0.01% + 25 mV
Current Line Regulation0.01% + 2 mA

Ripple and Noise

ParameterValue
Constant Voltage Ripple and Noise (Vrms)50 mV
Constant Voltage Ripple and Noise (Vp-p)160 mV
Constant Current Ripple and Noise (Irms)5 mA

Programming Accuracy and Resolution

ParameterValue
Voltage Programming Accuracy0.07% + 400 mV
Current Programming Accuracy0.085% + 7 mA
Voltage Programming Resolution125 mV
Current Programming Resolution1.25 mA

Readback Accuracy and Resolution

ParameterValue
Voltage Readback Accuracy0.08% + 350 mV
Current Readback Accuracy0.09% + 6 mA
Voltage Readback Resolution125 mV
Current Readback Resolution1.25 mA

Transient Response and Dynamic Performance

ParameterValue
Transient Recovery Time< 2 ms

Protection Features

ParameterValue
Over-Voltage Protection (OVP) Range10 V to 550 V
Over-Temperature ProtectionYes

System Connectivity and Interfaces

ParameterValue
Analog Programming Interface0-5 V, 0-10 V, 0-4 kΩ, or 0-8 kΩ user-selectable

Physical and Mechanical

ParameterValue
Form Factor3U full-rack
Cooling System DesignForced-air cooling (internal fan)

Protection & Isolation

ParameterValue
Output Terminal Isolation±550 VDC maximum from chassis ground

Accuracy & Temperature Drift

ParameterValue
Voltage Temperature Coefficient0.01% + 5 mV per °C
Current Temperature Coefficient0.02% + 0.5 mA per °C

Output Characteristics

ParameterValue
Remote Sensing Lead DropUp to 2 V maximum per load lead

Environmental

ParameterValue
Storage Temperature Range-20 °C to +70 °C

Programming & Control

ParameterValue
Command LanguagesSCPI, Compatibility Mode

AC Input

ParameterValue
AC Input Voltage Options100 VAC (Option 100) / 120 VAC (Standard) / 220 VAC (Option 220) / 240 VAC (Option 240)
AC Input Current17 A rms @ 120 VAC / 10 A rms @ 220 or 240 VAC
AC Input Frequency48 to 63 Hz
Maximum Input Power1600 VA
Power Factor0.7 (typical)

OVP Specifications

ParameterValue
OVP Programming Accuracy1.6% + 10 V
OVP Programming Resolution2 V

Programming Response Time

ParameterValue
CV Up-Programming Time (Full Load)150 ms
CV Up-Programming Time (No Load)150 ms
CV Down-Programming Time (Full Load)150 ms
CV Down-Programming Time (No Load)2000 ms
Command Processing Time15 ms

Stability

ParameterValue
Output Voltage Drift (8 hours)0.03% + 40 mV
Output Current Drift (8 hours)0.03% + 2 mA

Regulatory & Compliance

ParameterValue
RFI ComplianceComplies with FCC Class A / VDE 0871 Class A

Technology

Linear-regulator / Switch-mode hybrid DC Power Supply

Applications