The Keysight (Agilent) 60504B is a 600-watt DC electronic load module designed for use with compatible electronic load mainframes. It is ideal for the test, evaluation, and characterization of DC power sources and power components in research and development, production, and incoming inspection applications.

Specifications

General

ParameterValue
DisplayNone (utilizes mainframe display)

Physical

ParameterValue
Power SupplyPowered directly by the mainframe backplane
Operating Temperature0 to 55 °C
Weight9.5
Slot WidthDouble-wide (occupies 2 mainframe slots)

Input Ratings and Operating Ranges

ParameterValue
Maximum Input Power600 W
Operating Voltage Range3 V to 60 V
Maximum Input Current120 A
Minimum Operating Voltage3 V (at full current)

Operating Modes & Accuracy

ParameterValue
Constant Voltage Range0 V to 60 V
Constant Current Range (Low)0 A to 12 A
Constant Current Range (High)0 A to 120 A
Constant Resistance Range (Low)0.017 to 0.5 Ohms
Constant Resistance Range (Medium)0.5 Ohms to 500 Ohms
Constant Resistance Range (High)5 Ohms to 5 kOhms

Measurement and Readback Accuracy

ParameterValue
Voltage Readback Resolution (GPIB)17 mV
Voltage Readback Resolution (Front Panel)20 mV
Current Readback Resolution (GPIB)34 mA
Current Readback Resolution (Front Panel)100 mA
Voltage PARD (Ripple and Noise)8 mV rms
Current PARD (Ripple and Noise, rms)6 mA rms
Current PARD (Ripple and Noise, p-p)60 mA p-p

Connectivity & Control Interfaces

ParameterValue
Analog Programming InputAnalog voltage control in constant current mode

Protection Features

ParameterValue
Over-Current ProtectionYes
Over-Voltage ProtectionYes
Over-Power ProtectionYes
Over-Temperature ProtectionYes
Reverse Polarity ProtectionYes

Performance

ParameterValue
Current Slew Rate (High Range)0.08 A/µs to 8 A/µs
Current Slew Rate (Low Range)0.008 A/µs to 0.8 A/µs
Voltage Temperature Coefficient100 ppm/°C
Current Temperature Coefficient150 ppm/°C
Resistance Temperature Coefficient300 ppm/°C

Transient Operation

ParameterValue
Transient Frequency Range0.25 Hz to 10 kHz
Transient Duty Cycle Range1% to 99% (0.25 Hz to 1 kHz) / 10% to 90% (1 kHz to 10 kHz)

Inputs & Outputs

ParameterValue
Maximum Sense Lead Drop2 V per lead
Maximum Remote Sense Common Mode Voltage60 VDC

Programming Accuracy

ParameterValue
Constant Current Programming Accuracy (High Range)0.12% + 120 mA
Constant Current Programming Accuracy (Low Range)0.12% + 40 mA
Constant Voltage Programming Accuracy0.1% + 75 mV
Constant Resistance Programming Accuracy (Low Range)2% + 6 mS
Constant Resistance Programming Accuracy (Medium Range)2% + 0.1 mS
Constant Resistance Programming Accuracy (High Range)2.5% + 2.5 µS

Readback Accuracy

ParameterValue
Voltage Readback Accuracy0.07% + 60 mV
Current Readback Accuracy (High Range)0.1% + 110 mA
Current Readback Accuracy (Low Range)0.1% + 20 mA
Peak Voltage Readback Accuracy2% + 160 mV
Peak Current Readback Accuracy (High Range)2% + 320 mA
Peak Current Readback Accuracy (Low Range)2% + 60 mA

Programming Resolution

ParameterValue
Constant Current Programming Resolution (High Range)30 mA
Constant Current Programming Resolution (Low Range)3 mA
Constant Voltage Programming Resolution15 mV

Isolation & Safety

ParameterValue
Maximum Terminal to Chassis Voltage±240 VDC

Technology

DC Electronic Load

Applications

Testing and evaluation of DC power sources and power components