The Keysight (Agilent HP) 66000 Series 150W Power Supply Modules offer flexible, high-density DC power solutions for Automated Test Equipment (ATE) and production test systems. These modular outputs, including models like the 66101A through 66106A, provide up to 150W per output, featuring GPIB control, SCPI programming, and advanced triggering capabilities for seamless integration and reliable performance.

Specifications

General

ParameterValue
InterfacesNone directly on module; controlled via mainframe's GPIB
DisplayNone (module controlled via mainframe)
Recommended Calibration Interval1 year

Physical

ParameterValue
Power SupplyPowered by 66000A Series mainframe
Operating Temperature0 to 55 °C
Dimensions (W×H×D)66 mm W × 217 mm H × 460 mm D
Weight5.5 kg
Cooling MethodForced air (via mainframe)
Acoustic Noise< 45 dBA (from mainframe)

Output Characteristics

ParameterValue
Maximum Output Power150 W
Output TypeDC
Output Voltage/CurrentModule dependent

Measurement Accuracy (Readback)

ParameterValue
Built-in MeasurementsYes

Protection Features

ParameterValue
Safety FeaturesYes

Programming and Control

ParameterValue
Control Interface TypeVia mainframe
Programming LanguageSCPI command set
Command ProcessingDrivers available
Multi-Supply ControlSerial link system
Output State StorageAutomated sequencing up to 20 steps
Triggering CapabilitiesAdvanced hardware and software triggering

Physical Characteristics

ParameterValue
Mainframe Compatibility66000 Series mainframe
Mainframe Slot Occupancy1 slot per module
Module AccessibilityFront-removable
Mainframe Rack Unit4U (for up to 8 modules)

General Information

ParameterValue
Modular Outputs Included66101A - 66106A, and -J options
Maximum Modules per Mainframe8
Available OptionOutput relays (open/close/polarity reversal)

Environmental

ParameterValue
Storage Temperature-40 to 75 °C
Humidity0 to 95% RH, non-condensing
Operating AltitudeUp to 3000 m

Compliance

ParameterValue
Safety ComplianceUL 3111-1, CSA C22.2 No. 1010.1, EN61010-1
EMC ComplianceEN61326-1

Output Connections

ParameterValue
Remote SensingRear panel terminals
Output TerminalsRear panel screw-type

Software & Control

ParameterValue
Programming DriversIVI-COM, IVI-C, LabVIEW (via mainframe)

Protection

ParameterValue
Overvoltage Protection (OVP)Adjustable, user-settable
Overcurrent Protection (OCP)Current limit acts as OCP
Thermal ProtectionYes

Performance

ParameterValue
Voltage Load Regulation0.01% of Vout + 1 mV (module dependent)
Current Load Regulation0.01% of Iout + 1 mA (module dependent)
Voltage Line Regulation0.01% of Vout + 1 mV (module dependent)
Current Line Regulation0.01% of Iout + 1 mA (module dependent)
Voltage Ripple (RMS, 20 Hz - 20 MHz)0.5 mVrms
Voltage Noise (Peak-to-Peak, 20 Hz - 20 MHz)5 mVp-p
Current Ripple (RMS, 20 Hz - 20 MHz)1 mA rms
Transient Response Time (Voltage)< 1 ms (for 50% load change, within 0.1% of final Vout)
Voltage Programming Accuracy0.05% of setting + 5 mV
Current Programming Accuracy0.1% of setting + 10 mA
Voltage Programming Resolution1 mV (module dependent)
Current Programming Resolution1 mA (module dependent)
Voltage Measurement Accuracy0.05% of reading + 5 mV
Current Measurement Accuracy0.1% of reading + 10 mA
Voltage Measurement Resolution1 mV (module dependent)
Current Measurement Resolution1 mA (module dependent)
Output Voltage Stability (8 hr)0.01% of Vout + 5 mV
Output Current Stability (8 hr)0.01% of Iout + 5 mA

Control & Programming

ParameterValue
Voltage Slew RateProgrammable
Current Slew RateProgrammable

Technology

Programmable DC Power Supply

Applications

Automated Test Equipment (ATE)