The Keysight Technologies 6811B is a highly flexible, single-phase AC power source and power analyzer rated at 375 VA. Engineered for applications like power supply testing, UPS evaluation, and avionics ATE, it integrates the functionality of an AC source, a DC source, an arbitrary waveform generator, and a comprehensive power analyzer within a compact 3U rackmountable form factor.
Specifications
General
| Parameter | Value |
|---|---|
| Interfaces | GPIB (IEEE-488), RS-232, Remote Inhibit, Discrete Fault |
| Display | VFD (Vacuum Fluorescent Display) |
| Recommended Calibration Cycle | 1 year |
Physical
| Parameter | Value |
|---|---|
| Power Supply | 99 to 135 VAC / 198 to 264 VAC (user switchable), 47 to 63 Hz |
| Operating Temperature | 0 to 40 °C |
| Dimensions (W×H×D) | 425.5 mm × 132.6 mm × 571.5 mm |
| Weight | 23.0 |
AC Output Ratings
| Parameter | Value |
|---|---|
| Maximum AC Power Rating | 375 VA |
| Output Phase Configuration | Single-phase |
| AC Voltage Ranges | 135 Vrms / 270 Vrms |
| Maximum AC RMS Voltage | 300 Vrms |
| Maximum AC RMS Current (135 V range) | 3.25 Arms |
| Maximum AC RMS Current (270 V range) | 1.625 Arms |
| Maximum Peak Repetitive Current (135 V range) | 12 A |
| Maximum Peak Repetitive Current (270 V range) | 6 A |
| Peak Current Crest Factor Capability | 3.6 |
| Frequency Range | 45 Hz to 1000 Hz |
| Frequency Resolution | 10 mHz |
| Frequency Programming Accuracy | 0.01% |
DC Output Ratings
| Parameter | Value |
|---|---|
| Maximum DC Power Rating | 285 W |
| DC Voltage Ranges | 190 VDC / 380 VDC |
| Maximum DC Voltage | 425 VDC |
| Maximum DC Current (190 V range) | 2.5 A |
| Maximum DC Current (380 V range) | 1.25 A |
Output Distortion and Regulation
| Parameter | Value |
|---|---|
| Total Harmonic Distortion (THD) - Full Load (50/60 Hz) | < 0.5% |
| Total Harmonic Distortion (THD) - Full Load (45 Hz to 1 kHz) | < 1.0% |
| AC Load Regulation | 0.5% of full scale |
| AC Line Regulation | 0.1% of full scale |
| DC Load Regulation | 0.5% of full scale |
| DC Line Regulation | 0.1% of full scale |
| Programming Voltage Accuracy (AC, 135 V range) | 0.15% of output + 0.3 V |
| Programming Voltage Accuracy (AC, 270 V range) | 0.15% of output + 0.6 V |
| Programming Voltage Accuracy (DC, 190 V range) | 0.1% of output + 0.5 V |
| Programming Voltage Accuracy (DC, 380 V range) | 0.1% of output + 1.0 V |
Measurement and Analyzer Capabilities
| Parameter | Value |
|---|---|
| Voltage RMS Measurement Range | 0 to 300 V |
| Voltage RMS Measurement Accuracy (45 Hz to 100 Hz, 135 V range) | 0.15% of reading + 0.3 V |
| Voltage RMS Measurement Accuracy (45 Hz to 100 Hz, 270 V range) | 0.15% of reading + 0.6 V |
| Current RMS Measurement Accuracy (45 Hz to 100 Hz, Low range) | 0.5% of reading + 1.5 mA |
| Current RMS Measurement Accuracy (45 Hz to 100 Hz, High range) | 0.5% of reading + 15 mA |
| Active Power Measurement Accuracy (45 Hz to 100 Hz, Low range) | 1.5% of reading + 1 W |
| Active Power Measurement Accuracy (45 Hz to 100 Hz, High range) | 1.5% of reading + 3 W |
| Apparent Power Measurement Accuracy (45 Hz to 100 Hz, Low range) | 1.5% of reading + 1 VA |
| Apparent Power Measurement Accuracy (45 Hz to 100 Hz, High range) | 1.5% of reading + 3 VA |
| Power Factor Measurement Range | 0.00 to 1.00 |
| Crest Factor Measurement Range | 1.0 to 10.0 |
| Harmonic Analysis Frequency Range | Fundamental (45 Hz to 1000 Hz) up to 50th harmonic |
Waveform and Transient Generation
| Parameter | Value |
|---|---|
| Standard Waveform Types | Sine, Square |
| Arbitrary Waveform Point Capacity | 1024 points |
| Transient Programming Modes | Step, Pulse, List |
| Phase Angle Control Range | 0 to 360 degrees |
| Phase Angle Programming Accuracy | 1 degree |
| External Analog Modulation Input | Yes |
System Connectivity and Control
| Parameter | Value |
|---|---|
| Command Language Support | SCPI |
Protection and Safeguards
| Parameter | Value |
|---|---|
| Over-Voltage Protection (OVP) | Yes |
| Over-Current Protection (OCP) | Yes |
| Over-Temperature Protection (OTP) | Yes |
Physical and Environmental
| Parameter | Value |
|---|---|
| Storage Temperature Range | -40 to 75 °C |
| Cooling Mechanism | Forced-air with rear exhaust |
| Rack Unit Height | 3U |
Power Input
| Parameter | Value |
|---|---|
| AC Input Power Consumption | 1000 VA maximum |
| AC Input Frequency Range | 47 Hz to 63 Hz |
| AC Input Voltage Option 100 Range | 87 VAC to 106 VAC |
| AC Input Voltage Option 120 Range | 104 VAC to 127 VAC |
| AC Input Voltage Option 200 Range | 174 VAC to 220 VAC |
| AC Input Voltage Option 230 Range | 191 VAC to 254 VAC |
Outputs
| Parameter | Value |
|---|---|
| Output Isolation Voltage | 300 VAC / 425 VDC maximum relative to chassis ground |
| Remote Sensing Capability | Up to 2 V drop per output lead |
Programming Accuracy
| Parameter | Value |
|---|---|
| Voltage Programming Temperature Coefficient | 0.04% + 0.02 V per °C |
| Frequency Programming Temperature Coefficient | 10 ppm per °C |
Measurement Resolution
| Parameter | Value |
|---|---|
| Voltage RMS Measurement Resolution | 0.01 V |
| Current RMS Measurement Resolution (Low Range) | 1 mA |
| Current RMS Measurement Resolution (High Range) | 10 mA |
Measurement Performance
| Parameter | Value |
|---|---|
| Maximum Harmonic Measurement Order | 50th harmonic (for fundamental frequencies <= 250 Hz) |
Environmental
| Parameter | Value |
|---|---|
| Maximum Operating Altitude | 2000 m |
Measurements
| Parameter | Value |
|---|---|
| DC Voltage Measurement Range | 0 to ±190 VDC / 0 to ±380 VDC |
| Frequency Measurement Resolution | 0.01 Hz |
| Phase Angle Measurement Resolution | 0.1° |
| Active Power Measurement Resolution | 0.01 W (low range) / 0.1 W (high range) |
| Apparent Power Measurement Resolution | 0.01 VA (low range) / 0.1 VA (high range) |
| Power Factor Measurement Resolution | 0.01 |
| Crest Factor Measurement Resolution | 0.01 |
Output Characteristics
| Parameter | Value |
|---|---|
| Programmable Resistance Range (Option 005) | 0 to 1.0 Ω |
| Programmable Inductance Range (Option 005) | 0 to 2 mH |
Inputs & Outputs
| Parameter | Value |
|---|---|
| Remote Inhibit (RI) and Discrete Fault Indicator (DFI) | Available on rear panel terminal block |
Compliance
| Parameter | Value |
|---|---|
| Safety Standards Compliance | Certified to CSA C22.2 No. 1010.1, EN 61010-1, UL 3111-1 |
| EMC Standards Compliance | Complies with EN 55011, EN 50082-1 |
Technology
Linear / Switching Hybrid
Applications
Power supply testing, UPS testing, avionics ATE, and power factor corrected equipment evaluation